ERECTION OF DATA CENTRE FOLLOWING DEMOLITION OF EXISTING BUILDINGS, WITH ASSOCIATED PARKING, SERVICING, PLANT AND LANDSCAPING FOR CEREP BEDFORD SARL AND TRE GLOBAL UK LTD AT TWINWOOD BUSINESS PARK, MILTON ERNEST - 09/01085/MAF
DecidedPlanning1 paper
Planning Committee decided this item on Monday 3 August 2009. Below is the council's own wording, with the papers it was decided on.
That, subject to the satisfactory resolution of the noise and surface water drainage issues, permission be granted in respect of the above application in accordance with the recommendation of the Assistant Director (Planning and Housing). AD(P&H)
Word for word from the decision Bedford published for this meeting.Source: councillorsupport.bedford.gov.uk
6(1) ERECTION OF DATA CENTRE FOLLOWING DEMOLITION OF EXISTING BUILDINGS, WITH ASSOCIATED PARKING, SERVICING, PLANT AND LANDSCAPING FOR CEREP BEDFORD SARL AND TRE GLOBAL UK LTD. LAND AT TWINWOOD BUSINESS PARK, MILTON ERNEST – 09/01085/MAF
(a) Introduction and Reason for Report:
To enable Members to determine the planning application having regard to all the material planning considerations set out below and having regard for the representations received.
(b) Recommendation:
That Members grant planning permission subject to the schedule of conditions set out at the end of the report.
(c) Resource Implications:
None.
(d) Details:
The proposal is to erect a data centre containing data storage equipment with integrated offices within a two storey building [extending to 21,483 square metres] with associated plant, parking and loading areas. The principal purpose of such a facility is to provide a secure and completely reliable point of support for major financial institutions, government departments, and other large scale data processing and storing organisations.
Item 6(1) – page - 1 - A data centre comprises a series of data halls, which house computer server systems with ancillary support equipment. The office element houses staff who provide administrative and IT support to the engineers who ensure the constant operation and maintenance of the centre. In this case the operation is 24 hours a day, 365 days of the year. There will be 20-30 staff on site during the day, and 10-15 at night. The vertical height of the building is determined by the need for a floor void to deliver cooling air to the computer systems and by the requirement to provide a coordinated installation of power cables, cooling pipes and air ducts. A data centre is served by a series of power generators and chiller units, which are accommodated externally. There are diesel tanks to power back-up generators. Such centres need to be of a particular size to achieve a critical mass – ie to provide enough storage capacity to make their development viable.
Members may recall that a similar scheme was refused permission in September 2008. The reasons were:
• The development was contrary to the spatial strategy of the development plan and insufficient information had been submitted to justify an exception being made • The development formed an intrusion into an area of open undeveloped land and would be detrimental to the character and appearance of the area • The application failed to demonstrate that there would be no adverse impact on the area and the occupants of the nearest noise sensitive premises by reason of the operation of the proposed generators and chillers. • The creation of a precedent for similar proposals in the area.
This second application sets out to address these issues and is supported by a Design and Access Statement, Planning Statement, Landscape and Drainage Strategies including a Flood Risk Assessment, Sustainability and Energy reports, Transport Assessment, Hedgerow Survey, Noise report, Archaeology and Historic Buildings reports, Land Availability Assessment.
Consultations
Milton Ernest Parish Council – in favour of the data centre; it will create few traffic movements and is a quiet, clean technology. It will also encourage other high tech clean businesses to locate to the Business Park which aligns with the proposed strategic long term development for the whole site.
Clapham Parish Council – fully support the scheme.
Thurleigh Parish Council – no response.
Item 6(1) – page - 2 - Environment Agency – Flood Risk Assessment acceptable; surface water drainage strategy conflicts with the FRA and doesn’t adequately cover sustainable drainage systems and certain technical matters. Therefore object.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
ERECTION OF DATA CENTRE FOLLOWING DEMOLITION OF EXISTING BUILDINGS, WITH ASSOCIATED PARKING, SERVICING, PLANT AND LANDSCAPING FOR CEREP BEDFORD SARL AND TRE GLOBAL UK LTD AT TWINWOOD BUSINESS PARK, MILTON ERNEST: 09/01085/MAFReport
27ERECTION OF DATA CENTRE FOLLOWING DEMOLITION OF EXISTING BUILDINGS, WITH ASSOCIATED PARKING, SERVICING, PLANT AND LANDSCAPING FOR CEREP BEDFORD SARL AND TRE GLOBAL UK LTD AT TWINWOOD BUSINESS PARK, MILTON ERNEST - 09/01085/MAFThis decision
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.