Resolved
That, subject to the deletion of Condition 11 and to the following additional conditions, permission be granted in respect of the above application in accordance with the recommendation of the Assistant Director (Planning, Strategic Transport and Housing): Condition No. 15 There shall be no development until details of a scheme for the provision of flow data through the turbines has been submitted to and agreed in writing by the local planning authority, such details to be fully implemented before construction on site commences. Reason for Condition: Operation of turbines would render the current flow rating inaccurate and unusable, meaning flows could not be calculated as at present. The LPA in association with the Environment Agency would need to be provided with means to acquire 15 minute flow data through the turbines, in real time. This would have to be compatible with existing telemetry infrastructure. The accuracy of flow measurements would also need to comply with Environmental Agency standards and is required for ongoing operational requirements, such as monitoring of flows for flood resilient management. Condition No. 16 There shall be no development until a scheme for the provision and management of compensatory habitat creation has been submitted to and agreed in writing by the local planning authority and implemented as approved. Thereafter the development shall be implemented in accordance with the approved scheme. Reason for Condition As highlighted in the submitted Fisheries Report (Keystone Environmental Ltd.), there will be a net loss of juvenile coarse fish habitat under the current proposals. This area has been estimated to be 148 square metres. Under the Water Framework Directive "no deterioration" principle, creation of an additional 148 square metres of similar habitat is required within the same river reach i.e. Kempston Weir (NGR TL0197047607) downstream to Cardington Sluice (NGR TL0790248891). Government policy in Planning Policy Statement 9 states that where proposed development would cause significant adverse impacts on biodiversity interests, which cannot be prevented or adequately mitigated against, appropriate compensatory measures should be sought. Condition No. 17 The development permitted by this planning permission shall only be carried out in accordance with the approved Flood Risk Assessment (FRA) dated March 2011, by T J Booth Associates, reference FRA3 and the following mitigation measures detailed within the FRA: 1. Works to mitigate potential loss or interruption of flood flows across the site are implemented prior to commencement of the construction of the ... view the full minutes text for item 9.