RESOLVED that the application be granted whilst delegating final determination to the Head of Planning with a view to securing the necessary s106 agreement (reflecting the s106 of the existing planning consent)– in order to secure affordable housing contributions and all necessary mitigation measures, and for relevant amendments to be made to conditions to reflect the changes as set out in the new application; including the gym use being explicitly for residents. Voting: For – 10 Against – 3 Abstain – 0
Word for word from the decision Bournemouth, Christchurch and Poole published for this meeting.Source: democracy.bcpcouncil.gov.uk
Follow this further
Built from Bournemouth, Christchurch and Poole's papers
NOTES 1. The contents of this drawing are copyright. SCHEDULE OF ACCOMMODATION 2. Do not scale. Figured dimensions only to be used. 3. Contractors must verify all dimensions and report any discrepancies before putting work in hand or making any shop drawings. 4. All flat roofs to be fitted with a man safe system. PROPOSED RESIDENTIAL 5. Please note a domestic sprinkler system may be required - check with your building control inspector 6. Fixed shut fire safety glass windows may be required where windows are in close proximity to boundaries (subject to building regulations). 1ST FLOOR LEVEL 7. Stair design to be independently checked by stair fabricator for regs. compliance, prior to construction/ ordering. 8. Maclennan waterproofing specialists (or similar company with relevant PI insurance) to be instructed and detail all basement waterproofing designs. - ARC UNIT 1: 1 BED FLAT @ 42.1 SQM / 453 SQFT BATH carry no responsibility for basement designs in UNIT 2: 1 BED FLAT @ 41.3 SQM / 444 SQFT BED 1
LIVING terms of waterproofing or structure in any way. 9. “AS BUILT” drawings will only be issued upon request from the client/ UNIT 3: 1 BED FLAT @ 45.8 SQM / 493 SQFT contractor. All information within as built drawings is to be confirmed and provided by the client/ contractor. ARC Architecture do not perform regular site UNIT 4: 1 BED FLAT @ 44.1 SQM / 475 SQFT KITCHEN inspections to guarantee as built information so contractor or client must BATH sign a letter from ARC to confirm compliance with our plans on site. UNIT 5: 1 BED FLAT @ 43.8 SQM / 471 SQFT
ST BED 1 16 10. Any discrepancies between specification notes and details must be clarified for design intention with ARC before continuing with construction. UNIT 6: 1 BED FLAT @ 51.2 SQM / 551 SQFT 15 11. At Building Regulation stage our instruction is to gain a certificate of building 12 LIFT regulations compliance from the chosen inspector (LA or Private) UNIT 7: 2 BED FLAT @ 76.5 SQM / 823 SQFT 1 IN LIVING DINING ST 12. To ensure compliance with EWS1 fire safety forms an independent and an UNIT 8: 2 BED FLAT @ 60.9 SQM / 655 SQFT KITCHEN appropriately qualified and insured fire consultant / engineer should be appointed by the client to ensure the finished project can be mortgaged. GYMNASIUM @ 125.0 SQM / 1345 SQFT 13. A design and risk assessment should form part of our drawing package, if you have not received this from us by post, email or collection please contact us for UNIT 9: 2 BED FLAT @ 79.4 SQM / 854 SQFT a copy before moving forward with the project. 14. At planning stage planning drawings are to only to used for planning UNIT 10: 1 BED FLAT @ 52.3 SQM / 563 SQFT LIVING KITCHEN SMOKE VENT
KITCHEN purposes. PLEACHED LIVING
UNIT 11: 1 BED FLAT @ 43.9 SQM / 472 SQFT HOLM OAKS
9 UNIT 12: 1 BED FLAT @ 45.5 SQM / 489 SQFT
1 IN LEGEND DINING ST DINING
UNIT 13: 2 BED FLAT @ 62.8 SQM / 676 SQFT 1.72 ST. 1 RECEPTION UNIT 14: 2 BED FLAT @ 58.7 SQM / 632 SQFT BED 2 BED 1
SITE BOUNDARUY UNIT 15: 1 BED FLAT @ 40.1 SQM / 431 SQFT Bollards LIFT 3.60 1.72 14 BATH
UNIT 16: 1 BED FLAT @ 45.8 SQM / 493 SQFT PLEACHED to be designed SPRINKLER'S OR FANS HOLM OAKS TO BE CONFIRMED BED 1 BATH in car park KITCHEN area
1 IN 12 LIVING
ST DINING
2ND FLOOR LEVEL KITCHEN
SEMI MATURE LIVING 2 HOLM OAK 3.60 M4(2) ACCESSIBLE AND 1100mm HIGH UNIT 17: 1 BED FLAT @ 42.1 SQM / 453 SQFT BRICK ASSUMED SPRINKLERS DINING BATH BED 1 ADAPTABLE DWELLINGS WALL TO BLOCK 815sq.m UNIT 18: 1 BED FLAT @ 41.3 SQM / 444 SQFT CAR HEAD LIGHTS OPEN SIDED 3.60 REQUIRED TO ALL UNITS ST
13 UNIT 19: 1 BED FLAT @ 45.8 SQM / 493 SQFT UNDER-CROFT BED 2
UNIT 20: 1 BED FLAT @ 44.1 SQM / 475 SQFT AREA KITCHEN
SERVICES UNIT 21: 1 BED FLAT @ 43.8 SQM / 471 SQFT BED 1 BATH ST
DINING LIVING
UNIT 22: 1 BED FLAT @ 51.2 SQM / 551 SQFT PLEACHED HOLM OAKS DEMOLITION SMOKE VENT 3 OUTLINE OF BUILDING OVERHEAD
C O UNIT 23: 2 BED FLAT @ 76.5 SQM / 823 SQFT
M SEMI MATURE LIVING
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
Follow Planning Committee at Bournemouth, Christchurch and Poole and we tell you when its next papers are published, before the meeting rather than after it.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.