CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Bridgend County Borough Council
Development Control Committee, Thursday 19 October 2023

P/22/716/FUL - Land to the South of Felindre Road, Pencoed, CF35 5HU

Approved Planning 1 paper

Development Control Committee approved this item on Thursday 19 October 2023. Below is the council's own wording, with the papers it was decided on.

Item163

Resolved

That the above application be granted, subject to the Conditions contained in the report of the Corporate Director - Communities :- Proposal: Tactics facility building & external tactics equipment with access, landscaping, engineering and infrastructure works Subject to Condition 1 of the report now reading as follows:- 1. The development shall be carried out in accordance with the following approved plans and documents: • Proposed Site Plan (ref. ZZ 00 90 100 rev. P12); • Proposed Ground Floor Plan (ref. JFU-PDA-ZZ-00-DR-A-(05)200 rev. P05); • Proposed First Floor Plan (ref. JFU-PDA-ZZ-01-DR-A-(05)201 rev. P06); • Proposed Elevations 01 (ref. JFU-PDA-ZZ-ZZ-DR-A-(05)202 rev. P07); • Proposed Elevations 02 (ref. JFU-PDA-ZZ-ZZ-DR-A-(05)203 rev. P07). Reason: To avoid doubt and confusion as to the nature and extent of the approved development. Subject also to Condition 11 of the report being amended to read: 11. The acoustic barriers and bunds shall be erected at the locations and heights as shown in Figure 8.2 of the noise impact assessment by MACH Group (document reference: JFU-MAC-ZZ-XX-RP-Y-1001_Noise Impact Assessment_P04) and as shown on the amended site plan entitled JFU_PDA_ZZ-00-DR_A_90100-Proposed Site Plan (including the additional new proposed barrier at the Bus Location shown in Figure 1.1 of the technical note JFU-MAC-ZZ-XX-RP-Y-1007_Acoustic Response to Pre-Committee Comments). The acoustic barriers and bunds shall have a minimum mass density of at least 12kg/m2 mass per unit area and be a solid construction, with no gaps between the floor and the acoustic screen, must be non-permeable, rot-proof and have no gaps within the acoustic barrier itself. Prior to construction of the barriers/bunds, the design details shall be submitted to the Local Planning Authority for prior approval and shall be agreed in writing. The details shall include a location plan showing the position of the barriers, construction details and details confirming that the barrier/bunding has a minimum mass density of at least 12kg/m2. The design shall be implemented as agreed and the barrier shall be maintained in good condition and be retained in perpetuity. Should any part of the barrier become seriously damaged such that the effectiveness of its attenuation is reduced, it shall be repaired in good time with like-for-like materials, unless the Local Planning Authority gives written consent to any variation. Reason: In the interest of protecting the amenity of neighbouring uses.
Word for word from the decision Bridgend published for this meeting. Source: democratic.bridgend.gov.uk

Follow this further

Built from Bridgend's papers

What the report saysPro

Report to Development Control Committee

REFERENCE: P/22/716/FUL APPLICANT: South Wales Police & Crime Commissioner c/o Asbri Planning Ltd, Unit 9 Oak Tree Court, Cardiff Gate Business Park, CF23 8RS LOCATION: Land to the south of Felindre Road Pencoed CF35 5HU PROPOSAL: Tactics facility building & external tactics equipment with access, landscaping, engineering and infrastructure works RECEIVED: 19 October 2022 DESCRIPTION OF PROPOSED DEVELOPMENT The application seeks full planning permission for the development of a tactical training facility to be used for the training of officers of police constabularies in Wales and throughout the UK. The facility will be used primarily by South Wales Police, Dyfed Powys Police and Gwent Police, but will be available for use by other constabularies from across the UK as necessary.

There are only 6 facilities of this nature across the UK, and they are used to train all UK police officers in tactics and firearms for incidents that may arise. The facility is therefore of critical importance to national security. The proposed development will replace the existing facility at Waterton Industrial Estate, which is no longer fit for purpose.

Proposed site plan extract

The proposed development site includes land within the administrative boundaries of two local authorities – Bridgend CBC (BCBC) and Rhondda Cynon Taff CBC (RCT). The majority of the built development is located within the administrative boundary of BCBC and includes a part-two and part-three storey building which comprises offices, classrooms, warehouses and plant areas. Indoor training will consist of classroom-based learning, as well as an indoor firing range and tactical training area. Also included within the BCBC land are car parking areas, outdoor recreation space, landscaping and tactical training facilities such as a tower and a blockwork street scene. The RCT element of the proposals, which are not considered as part of this application, include areas for outdoor tactical training, as well as engineering, landscaping and infrastructure works. A separate planning application has been submitted to RCT for consideration by their own Officers and Members.

The proposed building will provide 12,835m2 of gross internal floor area across two floors, measuring a maximum of 87m in width and 136m in depth. To the north, the building will measure approximately 10m in height and includes a flat roof, with warehouse style buildings to the south of this measuring a maximum 14m in height and including both pitched roof and flat roof elements.

Proposed northern elevation

The proposed building is to be finished in composite panels of varying finishes in a palette of black and grey colours, alongside elements of glazing.

An outdoor training area is included immediately east of the building, which will include structures such as a working from heights tower and a blockwork streetscene where tactical scenarios will be undertaken. This area also includes areas of landscaping and swales, with a flood conveyance trench situated immediately to the east of the 2.4m tall perimeter fence which encloses the building on its southern, western and eastern sides.

The Ewenni Fach River forms the eastern boundary of the BCBC element of the application site, with further external training proposed to take place on the RCT portion of land to the east, alongside other works as described above.

The training facility will generally operate between 7am and 5pm Monday – Friday, with limited use at weekends. It is anticipated that the facility will be used by approximately 150 students and staff at any given time.

The site will be accessed using an existing access point from Felindre Road to the north. Car parking areas are proposed in the north and the south-west of the application site, including provision for EV parking spaces, as well as motorcycle and bicycle parking. Provision of PV solar panels is proposed at roof level of the main structure, alongside mechanical plant facilities to service the building.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
P/22/716/FUL: Land to the South of Felindre Road, Pencoed, CF35 5HUReport 523 KB DownloadRead as text

At this meeting

Whole meeting

Who was there

12 of 34 attended
AB
Councillor Anthony BerrowCommittee Member, present
C
Cabinet_CommitteeOfficer, expected
R-
Room - Council ChamberOfficer, expected
CN
Cynghorydd Norah ClarkeCommittee Member, apologies
CR
Cynghorydd Richard CollinsCommittee Member, apologies
CD
Councillor Chris DaviesCommittee Member, apologies
RD
Rhodri DaviesOfficer, in attendance
SE
Councillor Steven EasterbrookCommittee Member, present
LE
Lee EvansOfficer, expected
CF
Craig FlowerOfficer, in attendance
CR
Cynghorydd Richard GranvilleChairperson, present
HG
Councillor Heather GriffithsCommittee Member, present

All 34 on the meeting page

On this subject at Bridgend

Search all
  1. P/22/716/FUL - Land to the South of Felindre Road, Pencoed, CF35 5HUThis decision
  2. P/23/92/FUL - Land South of Former St. Johns School, (North of 22 Bryneglwys Gardens,) Newton, Porthcawl, CF36 5PRApproved
  3. P/23/218/FUL - Land at Brynmenyn and Bryncethin, BridgendAgreed
  4. P/22/756/FUL - Land at Bridgend Police Station & former Cheapside multi- storey car park, Bridgend, CF31 1BZRefused
  5. P/22/484/FUL - Land at Primrose Stables, Old Coachman’s Lane Court Colman, Bridgend, CF31 4NGAgreed
  6. P/22/597/FUL - Land formerly Ffaldau Arms, Victoria Street, Pontycymmer, CF32 8LLAgreed

More from Bridgend Development Control Committee

All decisions
MeetingDecisionOutcome
19 Oct 2023 Site VisitsThat a date for any site visits agreed by the Committee or identified in advance of the next meeting by the Chairpers... Agreed Open
19 Oct 2023 Approval of MinutesThat the Minutes of a meeting of the Development Control Committee dated 7 September 2023, be approved as a true and ... Approved Open
19 Oct 2023 Amendment SheetThe was accepted by the Chairperson as an urgent item under Part 4, paragraph 4 of the Council Procedure Rules. Decided Open
19 Oct 2023 Development Control Committee GuidanceThat the report of the Corporate Director – Communities, outlining the be noted. Noted Open
19 Oct 2023 P/23/147/FUL - Rear of 82 Merthyr Mawr Road, Bridgend, CF31 3NSThat the above application be granted, subject to the Conditions contained in the report of the Corporate Director – ... Agreed Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies