Outline planning permission granted It was proposed by Councillor Dennis Edgerley, seconded by Councillor Danny Gee, and subsequently RESOLVED to grant outline planning permission subject to the following conditions: 1. An application for approval of the reserved matters must be made to the Council before the expiration of two years from the date of this permission and the development hereby permitted must be begun either before the expiration of three years from the date of this permission, or before the expiration of one year from the date of approval of the last of the reserved matters to be approved, whichever is the later. Reason: Required to be imposed by Section 91 of the Town and Country Planning Act 1990 as amended by Section 51 of the Planning and Compulsory Purchase Act 2004. 2. Surface water must drain separate from the foul and no surface water will be permitted to discharge to the foul sewerage system. Reason: To secure proper drainage and in accordance with Policy Nos. EP17 and EM2 of the Adopted Chorley Borough Local Plan Review. 3. Prior to being discharged to any watercourse, surface water or soakaway system, all surface water drainage from parking areas shall be passed through trapped gullies with an overall capacity compatible with the site being drained. Reason: To prevent pollution of the Water Environment.
Word for word from the decision Chorley published for this meeting.Source: democracy.chorley.gov.uk
Proposal Outline application for the erection of new community fire station,
Location Fire Training Centre Washington Hall Washington Lane Euxton Chorley
Applicant [name removed]: The application is an outline application for the erection of a new community fire station, with all matters reserved apart from access.
Background: The application site forms part of Washington Hall, Lancashire Fire and Rescue Service International Training Centre, bounded on the North and East sides by Washington Lane and on the West and South Sides by West Way. The site is currently occupied by the fire appliance garage for the International Fire and Rescue Training Centre, which would be demolished to make way for the new Community Fire Station.
Planning History: The site has an extensive planning in relation to its use as a training centre.
Planning Policy: PPG2: Green Belts DC1: Development in the Green Belt DC6: Major Developed Sites in the Green Belt
Consultations: LCC Highways The Highways Section and the Traffic Section have no comments to make.
Planning Policy Have no objection providing it meets the criteria pf Policy DC6.
United Utilities Have no objection subject to conditions.
Environment Agency Request a condition be applied.
Coal Authority Standing Advice.
Representations: Euxton Parish Council Wishes to support the application.
Applicants Case: Lancashire Fire and Rescue Service (LFRS), as part of a major programme of providing improved fire and rescue services to the Chorley community have identified the site for a new Community Fire Station. This identification is as a result of a detailed assessment of areas of risk within the community.
Providing the service from this new location will enable LFRS to achieve response standards as detailed in their Integrated Risk Management Plan by moving the station into the centre of the 80,000 population it serves, from its current site on Weldbank Lane.
The current Fire Station is unsuitable for use as a Community Fire Station with poor accessibility, over-sized appliance bays and insufficient space for community related uses including facilities for training.
The Community Fire Station will be used to house two fire fighting appliances, one special appliance and their crews. It will also be used as a base for work promoting fire safety. It is intended that a community room would be included in the building which will accommodate groups of up to around 40 people and will be used to continue and enhance the promotion of fire safety messages as well as being available for community groups for meetings, seminars and training programmes.
LFRS avoid the use of audible warnings on vehicles unless it is deemed necessary to warn others of their presence. In particular, outside peak traffic hours they will only be used if required to indicate danger to others; in normal circumstances at quiet times it would not be necessary to use audible warnings.
Although only an outline application, including access it is intended that the new community fire station will be two storeys high and so reflect the massing of the existing buildings at Washington Hall. The height of the building will depend on the type of construction adopted but it is likely to be between 10m and 12m with the appliance storage facility being approximately 10m in height. The latter will replace an existing storage garage that is nearing the end of its economic life and is completely unsuited to the storage of modern fire fighting appliances.
Access onto and exit from the site will be via the existing site from Washington Hall onto Westway.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.