CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
East Hertfordshire District Council
Human Resources Committee, Wednesday 3 July 2013 at 3.00pm

Health and Safety : Long Term Faults and Defects

Noted Committee 2 papers

Human Resources Committee noted this item on Wednesday 3 July 2013. Below is the council's own wording, with the papers it was decided on.

Item99

Resolved

RESOLVED – that the report be noted.
Word for word from the decision East Hertfordshire published for this meeting. Source: democracy.eastherts.gov.uk

Follow this further

Built from East Hertfordshire's papers

What the report saysPro

Report to Human Resources Committee

Background

1.1The frequency of these inspections was increased following the appointment of the Facilities Team Leader with the full support and attendance of the Union’s Safety Representatives.

1.2Inspection regimes are a commonly used tool to assist management in the efficient and effective management of health and safety in the workplace.

2.0Report

2.1The purpose of these inspections is to identify faults, defects and hazards and assess the urgency of the remedy. However, only the most significant risks and breaches of statutory regulations will be reported to Safety Committee . The longer that matters remain unattended to, the greater the risk exposure to legal and financial penalties arising from claims for injury or harm, therefore funding or management support may be needed to rectify the situation. 2.2 Significant progress has been made since the introduction of the inspection regime and the appointment of the Facilities Team Leader 2.3 This report will be submitted to each Safety Committee meeting.

Suggested remedies / Defect / Hazard Consequence and action taken 1. Empty cleaners cupboard and Breach of the This has been reported to cleaning materials left in fire Fire Safety IT Manager, Facilities escape corridor Reform Order. Manager and Head of Service. This has also been reported to Safety Committee. All safe routes must be free and clear of obstructions. Assess storage and space requirements of cleaning contractors. Remove cupboard and ensure corridor is clear.

Current position: Arrangements have now been made to relocate cleaner’s cupboard.

2. Fire doors wedged open in IT area. Breach of the Ensure fire doors are Fire Safety closed at all times. Reform Order.

3. Weak / Inadequate fire Breach of the Health and Safety Officer suppression controls in IT server Fire Safety inspected this area with IT room, old building. Update, there Reform Order. Manager and undertook has been a lot of improvement in risk assessment identifying the server room in terms of a number of weaknesses housekeeping. at the time.

Current position: (a) Quotations for the suppression system were received several months ago and funding has been approved. However, this work has been put on hold pending decision on ICT Shared Services, i.e. potential move of servers to Stevenage. (b) Property Team has completed most of the building related work identified in risk assessment.

4. Defective fire door due to gap at Compromised Replace existing doors, base of door, access from fire safety fitted to accommodate reception to ground floor, south control uneven floor level to wing corridor. measure. achieve an effective fit.

Current position: This matter was referred to Building Control and efforts are being made to find a cost effective solution to reducing this gap this matter is only regarded as a low risk by their Fire Officer.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
Health and Safety : Long Term Faults and DefectsReport 52 KB DownloadRead as text
PDF
Health and Safety Long term Faults and Defects ERP AReport 15 KB Download

At this meeting

Whole meeting

On this subject at East Hertfordshire

Search all
  1. Health and Safety : Long Term Faults and DefectsThis decision
  2. Update on Quarter 4 Accident Reports and Annual Corporate Health and Safety Report for 2025/26Decided
  3. Health and Safety Annual Report 2024/25Decided
  4. Health and Safety Annual Report 2023/24Decided
  5. Health and Safety – Ward Freman PoolDecided
  6. Health and Safety Annual Report 2022/2023 including Q4 summaryDecided

More from East Hertfordshire Human Resources Committee

All decisions
MeetingDecisionOutcome
3 Jun 2026 Appointment of Vice - Chair for 2026/27RESOLVED – that Councillor Swainston be appointed as Vice-Chair of the Human Resources Committee for 2026/27. Decided Open
3 Jun 2026 Minutes - 4 February 2026RESOLVED – that the minutes of the meetings of the Human Resources Committee held on 4 February 2026, be confirmed as... Decided Open
3 Jun 2026 Local Joint Panel - Minutes of the meeting held on 19 May 2026RESOLVED – that the minutes of the meeting of the Local Joint Panel held on 19 May 2026, be noted. Noted Open
3 Jun 2026 Employee Health and Wellbeing Report 2025/26It was agreed that this area would receive additional focus and promotion through the mental health programme to help... Agreed Open
3 Jun 2026 Annual Turnover Report 2025/26RESOLVED – that the including the actions (in section 11.0) planned for 2026/27 be considered and any comments provid... Decided Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies