CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Epsom and Ewell Borough Council
Planning Committee, Thursday 10 July 2025 at 7.30pm

6A Bucknills Close, 11A and 13 Whitehorse Drive,

Refused Planning 2 papers

Planning Committee refused this item on Thursday 10 July 2025. Below is the council's own wording, with the papers it was decided on.

Item3

Resolved

Following consideration, Councillor Neil Dallen proposed that the application be refused for the following reason: Reason: Highway Safety Given there is inadequate space available within the site to accommodate both pedestrian and vehicular movements in a safe manner, the proposal would result in the risk of collision between vehicles and pedestrians using the access road, causing danger and inconvenience to pedestrians and other highway users and interfere with the free flow of traffic on the adjoining highway. This would be contrary to Section 9 of the National Planning Policy Framework 2023, Policy CS16 of the Core Strategy 2007. criterion 3 of Policy DM16 and Policies DM36 and DM37 of the Management Policies 2015, and objective 3 of the Surrey Transport Plan (LTP4) 2022-2032. The proposal was seconded by Councillor Humphrey Reynolds. The Committee resolved (2 for, 3 against, and 3 abstaining) and the motion was lost. Following further consideration, Councillor Kate Chinn proposed a motion to agree the Officer recommendation as set out in the report. The motion was seconded by Councillor Clive Woodbridge. Subsequently, the Committee resolved (5 for and 4 against) to: GRANT planning permission subject to a S106 Legal Agreement with the following Heads of Terms: a) Public Transport Improvements to bus stops on Dorking Road (Westlands Court and Epsom Hospital) to provide RTPI (Real Time Passenger Information) b) BNG delivery and monitoring c) Securing a Private Waste Collection Company in perpetuity and the following conditions and informatives: 1. Time Limit The development hereby permitted shall begin before the expiration of three years from the date of this permission. Reason: To comply with Section 91(1) of the Town and Country Planning Act 1990 as amended by Section 51(1) of the Planning and Compulsory Purchase Act 2004. 2. Approved Details The development hereby permitted shall be carried out in accordance with the following approved plans: Drawing Number 2025/P0296 LP Rev A Site Location Plan Drawing Drawing Number 2025/P0296 CP Rev A Site Context Plan Drawing Drawing Number 2025/P0296 001 Rev C Proposed Site Plan Drawing Number 2025/P0296 C001 Rev C Proposed Site Plan in Colour Drawing Number 2025/P0296 010 Plot 01 Proposed Plans and Elevations Drawing Number 2025/P0296 011 Plots 02 & 03 Proposed Plans and Elevations Drawing Number 2025/P0296 012 Plots 04 & 05 Rev A Proposed Plans and Elevations Drawing Number 2025/P0296 013 Plots 06, 07 & 08 Rev B Proposed Plans and Elevations Drawing Number 2025/P0296 014 Plot 09 Rev A Proposed Plans and Elevations Drawing Number CWLD-NH-BC-2485-01 Rev A Proposed Landscaping Arrangements ... view the full minutes text for item 3.
Word for word from the decision Epsom and Ewell published for this meeting. Source: democracy.epsom-ewell.gov.uk

Follow this further

Built from Epsom and Ewell's papers

What the report saysPro

Report to Planning Committee

PLANNING COMMITTEE UPDATE REPORT

App Number 25/00290/FUL Item Number Item 3 Address 6A Bucknills Close 11A And 13 Whitehorse Drive, Epsom, Surrey Proposal Demolition of residential dwelling at 6A Bucknills Close and office building at 13 Whitehorse Drive and the construction of nine residential units (3 x 2-bed, 6 x 3-bed) (Class C3) together with car parking, landscaping and access arrangements. Author Gemma Paterson Date 08/07/2025

UPDATE

1. Additional Third Party Comments

1.1Three letters of objection have received since the publication of the Agenda Report. Two of the objections raise no new material planning concerns beyond those reported in the Agenda Report.

1.2The remaining objection raises concerns in respect to the proposed drainage strategy and concerns to the use of underground storage, which is to be connected to a small on site pumping station for pump out controlled rate of 2l/s to an existing Thames Water combined sewer. The third party concerns are set out in bullet points below in bold, with the applicant’s drainage engineer’s response set out underneath:

 It is unlikely that the storage facilities could be entirely sealed from the surrounding ground, so will tend to fill with ground water during the winter to some extent. The pumping station would of course evacuate this, but pumping ground water to the public sewer would not be appropriate or acceptable to Thames Water.

The water entering the chambers will be from rainfall falling on the site and the chambers will be collecting water that they are supposed to collect, i.e. surface water run-off from the site. They will not be collecting groundwater - the water table is considerably lower than the proposed drainage structures, at around 20m below ground level.

 Solids in the form of sand, silt and possibly grit will inevitably be washed into the system. The velocities induced by emptying at 2l/s would be minimal, and insufficient to move accumulated siltation. The system would need to be inspected regularly and flushed as required, as acknowledged in the Drainage Report.

Sediment transport has been considered and a velocity of 0.75 m/s is usually considered sufficient to prevent the deposition of solids in pipework (self-cleansing velocity) and the diameter of pipework required to achieve this can be easily determined using the formula V=Q/A, where V is the velocity is m/s, Q is the discharge in m3/s and A is the cross sectional area of the pipe under consideration.

Using this formula gives a required pipe diameter of 58mm for a gravity system; but we are dealing with a pumped discharge here and not a gravity one, so pump curves/pump efficiency, static and friction heads also have to be considered. This is something that would normally be considered when selecting the pump and diameter of the rising main to ensure optimum efficiency of the system.

I would expect the pumped main on this site to have an OD (outside diameter) of somewhere between 40 and 63mm but the actual diameter will be determined by the pump and its impeller size, the optimum RPM it operates at, its efficiency and the dynamic head it has to operate against.

Not all pumps are created equal and each pump manufacturer will have a several different pumps which can be configured with different impellers to meet the different criteria. There are a quite a few variables to consider, but selecting the pump configuration and rising main combination will be selected to ensure that the system achieves (a) self-cleansing velocity and (b) efficient sediment transport in operation (i.e. so that sediment remains suspended and doesn't settle in the pipes).

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
6A Bucknills Close, 11A and 13 Whitehorse Drive: Update ReportReport 233 KB DownloadRead as text
PDF
6A Bucknills Close, 11A and 13 Whitehorse Drive,Report 1.7 MB Download

At this meeting

Whole meeting

Who was there

10 of 17 attended
SM
Councillor Steven McCormickChair, present
CW
Councillor Clive WoodbridgeVice-Chair, present
KC
Councillor Kate ChinnCommittee Member, present
ND
Councillor Neil Dallen MBECommittee Member, present
JF
Councillor Julian FreemanCommittee Member, present as substitute
AK
Councillor Alison KellyCommittee Member, apologies, sent representative
JM
Councillor Jan MasonCommittee Member, present
PN
Councillor Phil NealeCommittee Member, present
KP
Councillor Kieran PersandCommittee Member, present
HR
Councillor Humphrey ReynoldsCommittee Member, present
CW
Councillor Chris WatsonCommittee Member, absent
LF
Councillor Liz FrostCouncillor in Attendance, in attendance

All 17 on the meeting page

On this subject at Epsom and Ewell

Search all
  1. 6A Bucknills Close, 11A and 13 Whitehorse Drive,This decision
  2. 6A Bucknills Close, Epsom, Surrey, KT18 7NYRefused

More from Epsom and Ewell Planning Committee

All decisions
MeetingDecisionOutcome
5 Nov 2026 26/00879/FUL: The Lodge, Bourne Hall, Sprng Street, Ewell, Surrey, KT17 1UDFollowing consideration, Councillor Liz Frost proposed a motion that the Officer recommendation be agreed as set out ... Agreed Open
5 Nov 2026 26/00880/LBA: The Lodge, Bourne Hall, Spring Street, Ewell, Surrey, KT17 1UDFollowing consideration, Councillor Liz Frost proposed a motion that the Officer recommendation be agreed as set out ... Agreed Open
9 Jul 2026 26/00572/FUL Epsom Playhouse, Ashley Avenue, Epsom, Surrey, KT18 5ALFollowing consideration, Councillor Robert Leach proposed a motion that the Officer recommendation be agreed. The pro... Agreed Open
9 Jul 2026 25/01132/TPO Drummond Gardens, Christ Church Mount, Epsom KT19 8RPFollowing consideration, Councillor Neil Dallen proposed a motion that the Officer recommendation be agreed. The prop... Agreed Open
18 Jun 2026 25/01483/FUL Woodcote Stud, Wilmerhatch Lane, Epsom, KT18 7UEFollowing consideration, Councillor Dallen proposed a motion that the Officer recommendation be agreed. The proposal ... Agreed Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies