- Grant Full Planning Permission upon condition that:- 1. The development shall be carried out in accordance with the revised submitted drawing no. 13/01/0041/C. 2. The facing brick and roof tiles to be used are to exactly match those on the main dwelling unless otherwise agreed in writing with the Local Planning Authority. 3. The use shall not commence until the area within the site shown on drawing number 13/01/0041/C for the purposes of manoeuvring and parking of vehicles has been provided and thereafter that area shall be retained and used for no other purpose. INFORMATIVES 1 There is now a planning fee payable for applications in writing to discharge planning permission conditions. The rates as prescribed by Central Government are £97 for each written request (£28 for householder development).
Word for word from the decision Ipswich published for this meeting.Source: democracy.ipswich.gov.uk
BUILDING REGULATIONS - All work to conform to current Building Regulations, British Standards, Codes of Practice, Manufacturers Instructions, Structural Engineers Instructions and to be carried out to the full satisfaction of the Local Authorities, Building Control Officer including the submission of all necessary notices and payment of fees etc.
STRUCTURAL DESIGN - Construction specification to be read in conjunction with any structural calculations relating to project.
ELECTRICS - All electrics to be wired in accordance with latest IEE Regulations. Power outlets and light fittings to be located as directed by applicant. Efficient lighting to be provided in new building/extension/alterations as follows, one per 25m2 of newly created dwelling floor area or part there of, or one per four fixed lighting fittings. Efficiency lighting to comprise either basic lighting outlets or complete luminaries that only take lamps having a luminous efficacy greater than 40 lumens per circuit-watt. Examples of suitable lamps include fluorescent tubes and compact fluorescent lamps (not GLS tungsten lamps with bayonet cap or Edison screw bases). Fixed external lighting to be controlled via. sensors which automatically turn off lights Roof tiles to when not required and when there is sufficient daylight. Each external light fitting should not have a lamp capacity exceeding match existing 150W. All electrical work required to meet the requirements of Part P (Electrical Safety) must be designed, installed, Roof trusses to BS house 5268 Pt 3 1985 inspected and tested by a registered person competent to do so. Prior to completion the Council should be satisfied that Part P has been complied with. This will require an appropriate BS 7671 electrical installation certificate to be issued for the Roof tiles to work by a registered person competent to do so. match existing house HEALTH AND SAFETY - Work must be undertaken in accordance with the appropriate British Standard and follow all relevant Soft red facing brickwork Health and Safety Regulations. All dimensions must be checked by the builder on site prior to commencing work or ordering materials and components. The client is to be aware that the work shown should only be executed by competent builders who are fully proficient in all forms of safety procedure relating to all aspects of building, demolition and temporary shoring and the safe operation of all plant and equipment including personal protection. The builder and subcontractors should submit to the client his method statement of operation outlining his risk assessments, etc. relating to the work shown on the plans and detailed in the specification before commencing work.
PARTY WALL ACT - Main contractor to ensure that there will be no undermining of foundations to adjacent properties (where FRONT ELEVATION 1:100 SIDE ELEVATION 1:100 REAR ELEVATION 1:100 SIDE ELEVATION 1:100 applicable) and where new works of any nature are within 3 meters of adjacent owners property and boundary walls the main PROPOSED contractor is to ensure all relevant notices are served, and agreements obtained in accordance with the Party Wall Act 1996, GARAGE before any works are commenced.
ENCROACHMENT - No part of the structure above or below ground is to encroach over the boundary of adjacent properties without written consent from owners. 100mm concrete FOUNDATIONS - Final depth and size to be agreed on site with Local Authority Building Control Officer. Foundations shown in 1:3:6 mix concrete (20mm agg). Min. depth of 1m below finished ground level. Where trees are present in cohesive sub-soils DPC DPC depth to be determined in accordance with NHBC Standard foundation depth guidance notes - Chapter 4.2 or Structural Engineer consulted for fnd design. Drains where present passing through foundations to be sleeved and surrounded in a flexible material with vermin shield to outside face of foundations. Foundation to be provided under all external walls where
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.