That Planning Permission be granted, subject to the following conditions, as set out in the case officer’s report: 1. Standard timescale of development. 2. Development to be in full accordance with Amended Plans. 3. Flats to be occupied as student flats only. 4. No student accommodation to be provided on the lower ground floor. 5. Details to be agreed – details of sash and case divided windows, metal work to front steps of the building and repainting, new railings, roof lights, external doors, colour scheme for external joinery and metal work, mortar specification, entrance systems, vent extracts and their location. 6. Window at second floor level in the proposed en suite bathroom must not be re-glazed in obscure glass. 7. No vent extracts to be located on the façade facing Queen Street. 8. Bin storage details. 9. Cycle Storage details. 10. Hours of Construction (0800-1800 Monday to Friday, 0800-1400 on Saturday).
Word for word from the decision Lancaster published for this meeting.Source: committeeadmin.lancaster.gov.uk
5 Queen Street Change of use from non-residential institution (D1) to Lancaster four self contained student flats comprising of 12 Lancashire bedrooms in total LA1 1 RS
Name of Applicant Name of Agent
[name removed] Pitt Architects
Decision Target Date Reason For Delay
24 May 2012 Officer Workload
Case Officer [name removed] No
Summary of Recommendation Approval
1.0The Site and its Surroundings
1.1The building the subject of this application is a Listed Grade II three storey mid terraced townhouse constructed of natural stone and slate. It is located approximately 130 metres south of the junction of King Street and Queen Street on land forming part of a Conservation Area. The building is currently used by the Lancaster Girls’ Grammar School but is soon to be vacated as a consequence of the school’s new development on the west side of Queen Street.
2.0The Proposal
2.1This planning application seeks planning permission to use the building for student flats comprising of 12 bedrooms in total. The scheme has been amended in collaboration with the Local Planning Authority following concerns with regard to residential amenity. The scheme now excludes student accommodation within the basement of the building. The floor layout now comprises:
• Basement – Cycle and Bin Storage, Laundry Area and External Yard Area
• Ground Floor – Flat 1 comprises 2 bedrooms with an en-suite; and a separate Flat 4 comprising 2 bedrooms with an en-suite.
• First Floor – Flat 2 comprises 3 bedrooms with an en-suite
• Second Floor – Flat 3 accommodates 3 bedrooms with an en-suite and an additional mezzanine in roof space which provides 2 further bedrooms and an en-suite.
2.2A separate application seeks Listed Building Consent for the proposed conversion works. The building is considered to be structurally sound. 3.0 Site History
3.1There is limited planning history related with regard this property. The most relevant approved previous planning permission (1/91/0740) sought a Change of use from a Dancing School to Teaching Accommodation.
4.0Consultation Responses
4.1The following consultation responses have been received.
Consultee Response LCC Property No objection to the scheme. The occupiers of the property will not be eligible for Services - Parking residents parking permits for the Lancaster City Council Residents Parking Scheme for Central Zone A.
County Highways No objection to the scheme. The proposed cycle storage should be increased from 5 spaces to 10 spaces at a standard of 2 spaces for every 3 bedrooms of student accommodation. The need for additional cycle storage has now been addressed by way of the amended plans and can also be considered by way of planning condition.
Environmental No objection to the scheme subject to a condition which controls hours of Health construction (0800-1800 Mon to Fri, 0800-1400 on Sat).
Strategic Housing No objection to the scheme. Previous discussions with Lancaster University Student Union suggest that there is current and future need for the provision of student housing. Separate discussions are continuing with Lancaster University in relation to student housing need.
Lancashire No objection to the scheme. The officer has however raised the following issues; Constabulary • An access control system should be provided; • A minimum number of entrances compatible with resident’s convenience and fire safety should be provided; • A hierarchy of internal defensible spaces should be established; • Ground floor windows and those easily accessible above ground floor must be tested against a set of established standards including BS 7950; • Ground floor windows and those that are easily accessible to entry must have key operated locks.
These matters can addressed by way of providing an advice note should permission be granted.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
Car Park Nelson Street LancasterResolved : That the application be approved subject to the following conditions: 1. Development in accordance with Ap...
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.