Resolved
RESOLVED : ( Unanimous ) That permission be granted subject to the following conditions: 1. The development hereby permitted shall be commenced before the expiration of three years from the date of this permission or two years from the approval of the last of the reserved matters as defined in condition 2 below, whichever is the later. 2. Approval of the details of the layout, design and external appearance of the building, scale, landscaping, and access and parking (herein called the “reserved matters”) shall be obtained from the Local Planning Authority in writing before any development is commenced 3. The development hereby permitted shall be carried out in accordance with the approved site location plan submitted on 21st November2017 4. No development above slab level shall take place until samples of the materials (including colour of render, paintwork and colourwash) to be used in the construction of the external surfaces of the development hereby permitted have been submitted to and approved in writing by the Local Planning Authority. Development shall be carried out in accordance with the approved details 5. No development shall take place until details of a surface water drainage scheme have been submitted to and agreed in writing by the local planning authority. The surface water drainage scheme should be supported by an assessment of the site’s potential for disposing of surface water by means of a sustainable drainage system and be carried out or supervised by, an accredited person. An accredited person shall be someone who is an Incorporated ( IEng ) or Chartered (CEng) Civil Engineer with the Institute of Civil Engineers (ICE) or Chartered Institute of Water and Environmental Management (CIWEM). Where a sustainable drainage scheme is to be provided, the submitted details shall: a. provide information about the design storm period and intensity, the method employed to delay and control the surface water discharged from the site and the measures taken to prevent pollution of the receiving groundwater and/or surface waters b . be supported by a site investigation which incorporates ground water monitoring, preferably in winter, and soakage tests undertaken in accordance to BRE365 (when infiltration is proposed) c . provide a management and maintenance plan of the development which shall include the arrangements for adoption by any public authority or statutory undertaker and any other arrangements to secure the operation of the scheme throughout its lifetime 6. The implementation of the SUDS scheme should be carried out in accordance with ... view the full minutes text for item 105.