Resolved
RESOLVED that the application be APPROVED subject to standard conditions:
South Eastern Area Planning Committee approved this item on Wednesday 6 April 2022. Below is the council's own wording, with the papers it was decided on.
Resolved
RESOLVED that the application be APPROVED subject to standard conditions:
REFUSE for the reason as detailed in Section 8 of this report.
2. SITE MAP
Please see overleaf.
Our Vision: Sustainable Council – Prosperous Future 3. SUMMARY
3.1Proposal / brief overview, including any relevant background information
3.1.1 The application site is located to the north of Scotts Hill outside the defined settlement boundary of Southminster. The site is occupied by a two-storey detached dwelling of pitched roof design, which is set back from the main road by a substantial distance and is accessed via a track north of Scotts Hill. A group of residential properties fronting Scotts Hill are located to the east of the application site. To the north, east and west of the site are large expanses of open agricultural fields. Residential development along this part of Scotts Hill is sporadic and loose knit in character, with open agricultural fields along each side of the road.
3.1.2 Planning permission is sought for the construction of a single storey side to rear extension and two-storey rear extension. The existing single storey side and rear extensions at the property would be demolished to facilitate the proposed development. Whilst the two-storey rear part of the extension would extend from the main house, the single storey side to rear extensions would wrap around the east and north elevations of the property and the extensions would link into each other and be read as a single wrap-around extension.
3.1.3 The application follows a previously refused application for a similar development (20/01165/HOUSE refers). Since the previous application, which proposed a two- storey rear extension measuring 8m in depth, the two-storey rear part has been reduced in depth by 2m, so that it would now measure 6m in depth overall. The roof design of this part of the extension has also been amended so that it would now have a double pitched roof design with a central flat roof valley, instead of a tabletop/crown roof design. As a result of the amended roof design, the height of the two-storey extension has been increased so that it would now measure 6.9m in height at the ridge, instead of 6m.
3.1.4 The two-storey extension has also been set in from the side elevation of the main house by 1m so that the overall width of the two storey and single storey rear extension would now measure 18.3m instead of 19.3m. The width of the two-storey part would measure 10.4m and the width of the single storey rear part would measure 8.9m. The width of the single storey side extension would measure 7m when measured from the existing side wall of the main property. The overall depth of the single storey side and rear extensions would be 13m when measured from the front of the side extension; this has been reduced from 15m as part of the previous scheme.
3.1.5 The proposed single storey side and rear extensions would have the same height as the previous scheme, measuring 4.6m high overall at ridge height. The pitched roof part would extend from the eastern side wall of the existing dwelling; behind this element would be the flat roof element, which would measure 3m in height. Within the flat roof rear extension there would be a pyramid roof lights.
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
PDF |
22/00224/HOUSE: Pond House, Scotts Hill, Southminster, CM0 7BEReport | 305 KB | DownloadRead as text |
Follow South Eastern Area Planning Committee at Maldon and we tell you when its next papers are published, before the meeting rather than after it.
| Meeting | Decision | Outcome | |
|---|---|---|---|
| 16 Sep 2026 | Minutes of the last meetingRESOLVED that the Minutes of the meeting of the Committee held on 22 July 2026 be approved and confirmed. | Approved | Open |
| 22 Jul 2026 | Minutes of the last meetingRESOLVED (i) that the Minutes of the meeting of the Committee held on 24 June 2026 be received. Minute No. 5 – 24/008... | Agreed | Open |
| 22 Jul 2026 | 26/00296/FUL - Land At 1 Imperial Avenue, Mayland, CM3 6AQRESOLVED that this application be APPROVED subject to conditions including removal of the mobile home, restricting pe... | Approved | Open |
| 24 Jun 2026 | Minutes of the last meetingRESOLVED that the Minutes of the meeting of the Committee held on 8 April 2026 be approved and confirmed. | Approved | Open |
| 24 Jun 2026 | 25/00484/FUL - Burnham Waters Medical Centre, 4, Waters Avenue, Burnham-On-Crouch, EssexAgreed with Agent) Case Officer Chris Purvis Parish Burnham-on-Crouch Town Council Reason for Referral to the Committ... | Agreed | Open |
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Keeps you signed in and runs your free-paper allowance. Always on.
Counts visits and which pages are used. First-party only, no advertising, never shared.