CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Maldon District Council
South Eastern Area Planning Committee, Wednesday 15 February 2023 at 7.30pm

19/00929/FUL - Dock, The Quay, Burnham-On-Crouch, Essex

Approved Planning 2 papers

South Eastern Area Planning Committee approved this item on Wednesday 15 February 2023. Below is the council's own wording, with the papers it was decided on.

Item561

Resolved

RESOLVED that the application be APPROVED subject to the following conditions: Pre-commencement conditions are recommended, and the applicant/agent has been written to advise of the intention to use these conditions. If no response is received or no objection raised to the conditions within 10 days, the Local Planning Authority is able to impose the suggested conditions. The recommended below is made on the assumption that agreement is gained. 1. The development hereby permitted shall be begun before the expiration of three years from the date of this permission. 2. The development hereby permitted shall be carried out in accordance with the following approved plans and documents: · Drawing Number 1905/02rev.B: Block Plan & Existing Site Layout · Drawing Number 1905/03rev.B: Block Plan & Proposed Site Layout · Drawing Number 1905/04rev.A: Proposed Elevations & Cross Section. · Updated Preliminary Ecological Appraisal Report (December 2021) · Habitat Regulations Assessment Screening Report (October 2021) · Ecological Statement (July 2022) · Outline Method Statement (November 2021) · Flood Risk Assessment (December 2019) 3. No development shall take place unless details of flood resilience and resistance measures to be incorporated into the development and measures to secure houseboats to ensure they do not become floating debris have been submitted to and approved in writing by the local planning authority. The development shall be carried-out in accordance with the approved details and retained as such thereafter. 4. No vessel shall be moored within the site unless a Flood Warning and Evacuation Plan has been submitted to and approved in writing by the local planning authority. The use of the site shall be carried-out in accordance with the approved Plan, thereafter. 5. The public’s rights and ease of passage over public footpath 11 ... view the full minutes text for item 561.
Word for word from the decision Maldon published for this meeting. Source: democracy.maldon.gov.uk

Follow this further

Built from Maldon's papers

What the report saysPro

Report to South Eastern Area Planning Committee

Recommendation

APPROVE subject to the conditions as detailed in Section 8.

2. SITE MAP

Please see below.

Our Vision: Sustainable Council – Prosperous Future 3. SUMMARY

3.1Proposal / brief overview, including any relevant background information

3.1.1 The site is located in an area of intertidal mudflats and foreshore on The Quay on the seaward side of the seawall within Burnham-on-Crouch Conservation Area, opposite the Grade II listed War Memorial. The Quay forms part of a National Cycle route and accommodates a public right of way (No.11 Burnham-on-Crouch). The site extends down to Low Water Level of the River Crouch and is tidal.

3.1.2 Land either side of the site is understood to form part of Priors Boatyard which is used by residential houseboats with associated decks and jetties.

3.1.3 The application site was, until recently, occupied by a capsized, deteriorating former houseboat.

3.1.4 The site measures 18.5m along the northern boundary and 38.2m at the southern boundary.

3.1.5 The proposal includes the demolition of the existing structures within the tidal foreshore and on the riverside of the seawall. It is also suggested that the existing houseboats moored / berthed on the adjacent sites owned by Priors Boatyard are to be removed but these are not included within the application site.

3.1.6 It is proposed to install a new floating pontoon with steel supported access deck consisting of the following elements:  Access deck: 1.5m wide surfaced in timber (Yellow Balau or similar) with a handrail (steel tubular uprights with galvanized steel cables and hardwood handrail). The new access deck would extend along the river side of the existing seawall and gateways beyond the main eastern and western boundaries of the site (for a distance of 15m to the east and 21m to the west to link with the Priors Boatyard building). At the western end of the access deck would be a bin storage facility adjacent to flood gate 1 which would serve the existing and proposed houseboats.  Access bridge: 10m long x 1.5m wide (zinc spray painted structural steel frame with hardwood (Yellow Balau or similar) decking). The pontoon for the access bridge would measure7.5m long x 2.5m wide.  Floating pontoon: 53.5m long x 2.5m wide (floats would be fibre reinforced concrete covering expanded polystyrene; the pontoon would have a galvanized steel frame with hard wood (Yellow Balau or similar) decking and three support piles)

3.1.7 The development would accommodate four permanent berths for residential houseboats (which would be leased from Maldon District Council) which could be approximately 21m x 6m in size. The houseboats would be provided with mains electricity, mains fresh water and facilities for foul drainage which would all terminate in the Priors Boatyard building to the west of the site.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
19/00929/FUL: Dock, The Quay, Burnham-On-Crouch, EssexReport 610 KB DownloadRead as text
PDF
Members' UpdateReport 475 KB Download

At this meeting

Whole meeting

Who was there

9 of 11 attended
RP
Councillor Richard P F DewickChairperson, present
AS
Councillor Adrian S FlukerVice-Chairperson, present
MG
Councillor Mark G BassengerCommittee Member, present
BS
Councillor Brian S Beale MBECommittee Member, apologies
VJ
Councillor Vanessa J BellCommittee Member, present
RG
Councillor Robert G Boyce MBECommittee Member, apologies
MP
Councillor Mrs Penny A ChannerCommittee Member, present
MW
Councillor Michael W HelmCommittee Member, present
AL
Councillor Anne L HullCommittee Member, present
NJ
Councillor Nick J SkeensCommittee Member, present
WS
Councillor Wendy Stamp CCCommittee Member, present

More from Maldon South Eastern Area Planning Committee

All decisions
MeetingDecisionOutcome
16 Sep 2026 Minutes of the last meetingRESOLVED that the Minutes of the meeting of the Committee held on 22 July 2026 be approved and confirmed. Approved Open
22 Jul 2026 Minutes of the last meetingRESOLVED (i) that the Minutes of the meeting of the Committee held on 24 June 2026 be received. Minute No. 5 – 24/008... Agreed Open
22 Jul 2026 26/00296/FUL - Land At 1 Imperial Avenue, Mayland, CM3 6AQRESOLVED that this application be APPROVED subject to conditions including removal of the mobile home, restricting pe... Approved Open
24 Jun 2026 Minutes of the last meetingRESOLVED that the Minutes of the meeting of the Committee held on 8 April 2026 be approved and confirmed. Approved Open
24 Jun 2026 25/00484/FUL - Burnham Waters Medical Centre, 4, Waters Avenue, Burnham-On-Crouch, EssexAgreed with Agent) Case Officer Chris Purvis Parish Burnham-on-Crouch Town Council Reason for Referral to the Committ... Agreed Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies