25/01788/FUL Summertown House

Approved Planning 3 papers

AI summaryOxford City Planning Committee approved two air source heat pumps, window changes and replacement boundary railings and gate at Summertown House, subject to conditions [D]. It delegated final condition wording; the proposal is not liable for CIL [D] [P3] [P4] [P10].

AI summaryIn plain English

Written from the decision and the officer reportPDF Pro
OutcomeApprovedTwo heat pumps, window changes, new railings and gate [D].
MoneyNo CIL liability applies [P10].
What happens nextConditions to be finalised [D]Head of Planning and Regulatory Services will finalise wording [D].
Who it affectsSummertown House and neighbours [2.2]Conditions cover noise, vibration, trees and lighting [P178] [P181] [P188] [P191].

What was decided

Oxford City Planning Committee approved the application and granted planning permission, subject to the section 12 conditions and the amended wording of condition 4 agreed at committee [D] [P2] [11.9]. Report P2, 11.9

Authority was delegated to the Head of Planning and Regulatory Services to finalise the recommended conditions, including refinements, amendments, additions or deletions considered reasonably necessary [D] [P3] [P4]. Report P3, P4

The permission covers demolition of the existing railings and gate, two heat pumps on the north and south elevations, window alterations, and replacement boundary railings and gate [D] [2.1] [6.3]. Report 2.1, 6.3

Why

The heat pumps would support the University's net zero policy and better energy efficiency by enabling a transition from gas boilers [6.1] [10.4] [11.4]. Report 6.1, 10.4, 11.4

Officers found the location and design acceptable, with no harm to the Grade II listed Summertown House or its setting [10.13] [10.14] [10.15] [10.18] [10.19]. They found the proposal consistent with the Oxford Local Plan 2036 and Summertown and St Margaret’s Neighbourhood Plan [2.2]. Report 10.13, 10.14, 10.15, 10.18, 10.19, 2.2

The updated noise modelling was accepted despite objectors' assessments predicting higher garden and façade noise, with acoustic enclosures and a solid 2.9 metre high fence [10.25] [10.26] [10.27] [10.28]. Officers found no material considerations outweighing compliance with the development plan [11.8]. Report 10.25, 10.26, 10.28, 11.8

What happens next

The Head of Planning and Regulatory Services will finalise the recommended conditions, including refinements, amendments, additions or deletions considered reasonably necessary [D] [P3] [P4]. The development must follow the approved plans and materials unless the Local Planning Authority agrees otherwise in writing [P172] [P175]. Report P3, P4, P172, P175

Before use, the applicant must submit noise details for approval, complete a post installation assessment, and take further mitigation where needed. Machinery must use proprietary anti vibration isolators, and fan motors must be isolated from the casing, silenced and maintained [P178] [P181]. Report P178, P181

Before installation, the applicant must follow the approved tree protection methods, give the Council 5 days notice for relevant works, and secure approval of an arboricultural monitoring programme. If external lighting is installed, proof of compliant installation must be provided before operation [P185] [P188] [P191]. Report P185, P188, P191

Options considered

  • Chosen: Approve with conditions and grant planning permission. The proposal accords with the development plan and no material considerations outweighed those policies. Report P2, 11.5, 11.8
  • Chosen: Finalise and refine the recommended planning conditions. The committee delegated this authority to the Head of Planning and Regulatory Services. Report P3, P4

Implications

  • Climate: The proposal would support the University's net zero policy and reduce carbon emissions through a transition from gas boilers [6.1] [10.4] [11.4]. Report 6.1, 10.4, 11.4
  • Risk: Noise must not exceed the existing background level at the nearest or most affected noise sensitive premises, with post installation testing and further mitigation if needed [10.28] [P178]. Report 10.28, P178
  • Legal: Only two heat pumps are permitted, and any additional units need the Local Planning Authority's prior written consent [10.29] [P178]. Report 10.29, P178
  • Risk: Tree works must follow the approved Arboricultural Method Statement, with an approved monitoring programme before installation [10.37] [P184] [P188]. Report 10.37, P184, P188
  • Risk: The proposal was considered acceptable for flood risk, drainage, biodiversity, contamination and highways, subject to relevant conditions [2.2] [10.34] [10.43] [10.48] [10.50]. Report 2.2, 10.34, 10.43, 10.48, 10.50
  • Financial: The proposal is not liable for CIL [P10]. Report P10
  • Risk: Reported asbestos removal before permission was passed to the Council's planning enforcement and Health and Safety teams [9.10] [10.47]. Report 9.10, 10.47
  • Legal: No legal agreement is required [3.1]. The decision had to preserve the setting of the Grade II listed building under the higher statutory duty, and officers found that it did [10.19]. Report 3.1, 10.19

Who and where

  • Oxford University, the applicant Report 5.1, 6.1
  • Students in the three accommodation blocks Report 5.1
  • Neighbouring residents to the north, south and west Report 5.4
  • Occupiers of homes with gardens adjoining the site Report 5.4, 10.21
  • People who submitted objections Report 9.7, 9.8
  • Oxford Civic Society Report 9.5
  • Summertown and St Margaret’s Neighbourhood Forum Report 9.6
  • Council planning enforcement and Health and Safety teams Report 9.10

Timeline

  • 12th February 2024: Biodiversity Net Gain became a legal requirement for planning permission. This application was later treated as exempt [10.40] [10.41]. Report 10.40, 10.41
  • 5th August 2025: Four site notices began the original consultation, which received 54 objecting comments [9.1] [9.7]. Report 9.1, 9.7
  • 2nd October 2025: A related listed building application for internal alterations was permitted [P29]. Report P29
  • 6th October 2025: The applicant submitted an addendum to the noise assessment [9.2]. Report 9.2
  • 21st October 2025: Pink notices began the second consultation, which received 56 objecting comments [9.2] [9.8]. Report 9.2, 9.8
  • 6th November 2025: Members called the application in over noise and vibration, high quality design and external features [9.3] [9.4]. Report 9.3, 9.4
  • 2025-12-09: The committee approved the application and delegated final condition wording [D].
  • Not later than the expiration of three years from the date of this permission: Development must be begun [P169]. Report P169

Plain English for the jargon

  • ASHP: Air source heat pump, called an ASHP in the report [2.1].
  • CIL: Community Infrastructure Levy [P10].
  • BNG: Biodiversity Net Gain, a planning permission legal requirement [10.40].
  • TPO: Tree Preservation Order [10.36].
  • RPA: Root Protection Area [10.36].
  • AMS: Arboricultural Method Statement for tree protection and methods of working [P184].
  • AMP: Arboricultural Monitoring Programme for supervision and compliance checks [P188].
  • CTMP: Construction Traffic Management Plan [10.50].
What was decided, why, and what happens next

Pro reads every officer report for you and explains each decision in plain English: the money, the options, the risks, the timeline, each with the paragraph it came from.

Written by AI from the council's published papers. AI can get things wrong: the council's own wording below is the record.Report a problem
Item42

Resolved

Site address: Summertown House, 369 Banbury Road, OX2 7RD Proposal: Demolition of existing boundary railings and access gate, installation of 2 no. air source heat pumps to the North and South elevations. Alterations to fenestration, formation of new boundary railings and access gate. (additional information). The Oxford City Planning Committee resolved to: 1. Approve the application for the reasons given in the report and subject to the required planning conditions set out in section 12 (subject to the amended wording of condition 4 as agreed at Committee) of this report and grant planning permission 2. Delegate authority to the Head of Planning and Regulatory Services to: finalise the recommended conditions as set out in this report including such refinements, amendments, additions and/or deletions as the Head of Planning and Regulatory
Word for word from the decision Oxford published for this meeting. Source: mycouncil.oxford.gov.uk

Follow this further

Built from Oxford's papers

What the report saysPro

Report to Planning - Oxford City Planning Committee, 22 pages

Recommendation

1.1Oxford City Planning Committee is recommended to:

1.1.1. approve the application for the reasons given in the report and subject to the required planning conditions set out in section 12 of this report and grant planning permission

1.1.2. delegate authority to the Head of Planning and Regulatory Services to:

finalise the recommended conditions as set out in this report including such refinements, amendments, additions and/or deletions as the Head of Planning and Regulatory Services considers reasonably necessary

Executive summary

2.1This report considers the demolition of the existing boundary railings and access gate, the installation of 2 no. air source heat pumps (referred to as ASHP’s from this point onwards) to the north and south elevations. It also considers

85 alterations to fenestration, formation of new boundary railings and access gate.

2.2Officers conclude that the proposed development would be acceptable in principle and with regards to its design and impact on designated heritage assets including archaeology, subject to recommended conditions. The proposal would not cause any detrimental impacts to the amenity of any neighbouring dwellings, subject to the recommended conditions. The proposal would be acceptable in regard to flood risk and surface water drainage. The proposal would be acceptable in regard to tree impacts, subject to the recommended conditions. The proposal would result in no issues in regard to ecology and biodiversity, land contamination and highways. Overall, the proposal is considered to accord with Policies DH1, DH3, DH4, RE3, RE4, RE7, RE8, RE9, G2 and G7 of the Oxford Local Plan 2036. The proposal is also considered to accord with Policies HOS2 and HOS3 of the Summertown and St Margaret’s Neighbourhood Plan.

3. LEGAL AGREEMENT

3.1This application is not subject to a legal agreement.

4. COMMUNITY INFRASTRUCTURE LEVY (CIL)

4.1The proposal is not liable for CIL.

5. SITE AND SURROUNDINGS

5.1The application site is located in Summertown, to the north of Oxford city centre. The site is student accommodation for Oxford University, comprising of North, East, and West Blocks. The residential units are accommodated over three, five, and three storeys, respectively. The application site lies to the north of Summertown on the northern side of Apsley Road with the largest (East) block of accommodation fronting onto Banbury Road. The main access to the site is from two vehicular access points off Apsley Road. The site comprises the original Summertown House, which is a Grade II listed building situated centrally to the site, and three large 1960s blocks of post graduate student accommodation which surround it. A single storey building has been added to the rear of the listed house and is used as a day nursery operated by the the applicant (the University of Oxford).

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
25/01788/FUL Summertown HouseReport 22 pages DownloadRead as text
PDF
Site Plan Summertown House 25.01788.FULAppendix 1 2 pages Download
PDF
Summertown House (25.01788.FUL) Committee PresentationReport 16 pages Download

At this meeting

Whole meeting

On this subject at Oxford

Search all
  1. 25/01788/FUL Summertown HouseThis decision
  2. Planning application for determination - Summertown House, Banbury Road - 12/00239/FULDeferred
  3. Grove House Club, Grove Street, Summertown, Oxford: 11/01165/FULApproved

More from Oxford Planning - Oxford City Planning Committee

All decisions
MeetingDecisionOutcome
15 Sep 2026 25/01169/FUL Alice House, 25 St Clement's Street, Oxford, OxfordshireSite address: Alice House, 25 St Clement's Street, Oxford, Oxfordshire Proposal: Installation of 6no. antennas with t... Approved Open
25 Aug 2026 26/00796/FUL Oxenford House, 13 - 15 Magdalen Street, Oxford, OxfordshireThe Oxford City Planning Committee resolved to: 1. Approve the application?for the reasons given in the report and su... Approved Open
14 Jul 2026 25/01588/FUL Ozone Leisure Park, Grenoble RoadSite address: Ozone Leisure Park, Grenoble Road Proposal: Demolition of existing commercial and leisure buildings (Cl... Approved Open
14 Jul 2026 26/01199/LBC Minchery Farm Club, Minchery Farm Lane, Oxford, OxfordshireSite address: Minchery Farm Club, Minchery Farm Lane, Oxford, Oxfordshire Proposal: External and internal alterations... Approved Open
14 Jul 2026 24/01104/FUL 35 Ash Grove, Oxford, Oxfordshire, OX3 9JNSite address: 35 Ash Grove, Oxford, Oxfordshire, OX3 9JN Proposal: Demolition of existing garage and rear extension. ... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies