Agreed contract change to reduce printing weighbridge tickets; m) There had been a lighting review for LED exchange; They added information on the 2022/23 Current Status and highlighted – n) Due to plant efficiency across the years, MVV had requested SWDWP’s approval to increase capacity by 10ktp/a through Consent variation applications; o) MVV did not conduct a major outage this year but has reported 600 hours in lost availability to date due to a series of unplanned outages (6 in total) relating to tube leaks, de-slagger blockages and a malfunction of the bucket elevator in the APCR system; p) 2 justified odour complaints due to opening of safety valves during works in the bunker; q) 20 Performance Failures for minor operational matters surrounding vehicle deliveries and the community liaison. In response to questions it was explained – r) Enquiries had begun into increasing the planning and environmental permit of 265,000 waste throughput as it had come close to the limit in 2019 and 2020; s) Gas canisters had been exploding and causing damage to the grate, but that this was a common issue across the UK and the key to limiting this was education, which MVV worked with partners on; t) With regards to capacity, there was storage on site in a bunker larger than most, but also the possibility to bail and export to other sites if capacity was exceeded; u) Most ash was being transported to Exeter, but some exported to The Netherlands via Victoria Wharf.