Caterpillar Defence, Perkins Engines, Lancaster Road, Shrewsbury - 16/04559/OUT

Refused Planning 2 papers

Central Planning Committee refused this item on Thursday 25 October 2018. Below is the council's own wording, with the papers it was decided on.

Item58

Resolved

That planning permission be refused contrary to the Officer’s recommendation for the following reason: The proposed development would involve the use of protected employment land for residential development and would therefore be contrary to adopted development plan policies namely CS13 and CS14 (Core Strategy) and MD4 and MD9 (SAMDev). It was acknowledged that the proposal would involve development of a brownfield site and would deliver some benefits in terms of securing the applicants long term ... view the full minutes text for item 58.
Word for word from the decision Shropshire published for this meeting. Source: www.shropshire.gov.uk

Follow this further

Built from Shropshire's papers

What the report saysPro

Report to Central Planning Committee, 34 pages

Committee and date Item

Central Planning Committee 5 25 October 2018 Public

Development Management Report

Responsible Officer: Tim Rogers Email: [email protected] Tel: 01743 258773 Fax: 01743 252619

Summary of Application

Application Number: 16/04559/OUT Parish: Shrewsbury Town Council

Proposal: Outline application (access for consideration) for residential development (up to 140 dwellings) including demolition of building 1; formation of access roads and associated highways, engineering and accommodation works (REVISED SCHEME)

Site Address: Caterpillar Defence Perkins Engines Lancaster Road Shrewsbury Shropshire

Applicant: Caterpillar Defence

Case Officer: Tim Rogers email: [email protected]

Grid Ref: 350360 - 314958

© Crown Copyright. All rights reserved. Shropshire Council 100049049. 2016 For reference purposes only. No further copies may be made. Central Planning Committee – 25 October 2018 Item 5 - Caterpillar Defence Perkins Engines Lancaster Road Shrewsbury

Update to full officer report as set out below

This application was previously considered by Committee at the meeting held on the 30th August 2018. The officer report to that meeting is set out in full again below. Determination of the application was deferred for the following reason:- ‘That consideration of the application be deferred to a future meeting of this Committee to allow the applicant the opportunity to provide further information in regards to traffic issues identified by Members to include the impact on Mount Pleasant Road, and where it meets Ditherington Road, Heathgates island, and Boscobel Drive’.

Following the deferment the applicants have submitted some further clarification regarding their traffic impact assessment in the form of a non-technical summary note. The report is attached in full as Appendix 2 to this report.

The content of the attached report has again been assessed by colleagues within Highways Development Control and their technical advisors. They have made the following observations:-

Section 2.0 Additional Site Traffic – Mount Pleasant Road / Ditherington Road The technical reports referred to in the Transport Summary Notes (section 1.0) confirmed the Ditherington Road / Mount Pleasant Road junction is at capacity in the 2017 base year and this will get worse in the future year and worse again when the development traffic is added. The analysis showed that capacity is exceeded on two movements, the straight ahead / left turn from Ditherington Road south and the left turn out of Mount Pleasant. The degree of saturation in the am peak on these movements in 2022 increases from 102.5% to 104.9% and 105.1% to 109.0% with the development traffic added. The Transport Summary Note presents the Ditherington Road queue lengths in the different development scenarios (with and without the one-way working under the railway bridge) in a helpful visual format. It is clear how the queue length increases and how it does not reach the Lancaster Road roundabout in any of the modelled scenarios. I agree these increases can be viewed as marginal but nevertheless the development does make a congested situation worse. (Ref para 2.7)

Section 3.0 Heathgates Roundabout I support the position set out in this section.

Section 4.0 Off Site Mitigation I agree that it is not reasonable to ask this development to resolve the existing problem. As far as the increase in delays and queuing is concerned they are marginal and it is likely that that a scheme to remove them would not be practical or sensible to deliver. As far as the wider picture is concerned I suspect that there is very little that can be done at the Mount Pleasant / Ditherington Road junction within the extent of the highway.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
Caterpillar Defence, Perkins Engines, Lancaster Road, Shrewsbury: 16/04559/OUTReport 34 pages DownloadRead as text
PDF
Item 5 Appendix 2: Transport Summary NoteAppendix 9 pages Download

At this meeting

Whole meeting

On this subject at Shropshire

Search all
  1. Caterpillar Defence, Perkins Engines, Lancaster Road, Shrewsbury - 16/04559/OUTThis decision
  2. Caterpillar Defence, Perkins Engines, Lancaster Road, Shrewsbury - 16/04558/FULAgreed
  3. Caterpillar Defence, Perkins Engines, Lancaster Road, Shrewsbury - 16/04559/OUTDeferred

More from Shropshire Central Planning Committee

All decisions
MeetingDecisionOutcome
4 Jul 2019 MinutesThat the of the meeting of the Central Planning Committee held on 6 th June 2019 be approved as a correct record and ... Approved Open
4 Jul 2019 Land North East of Kinton, Shrewsbury - 18/00130/EIAThat consideration of the application be deferred to a future meeting of this Committee at the request of the applicant. Deferred Open
4 Jul 2019 Land Off Manor Lane, Longden, Shrewsbury - 16/02395/FULThat authority be delegated to the Head of Planning Services to refuse planning permission subject to further consult... Refused Open
4 Jul 2019 School House Farm, Sheinton, Shrewsbury - 18/04266/FULThat planning permission be granted as per the Officer’s recommendation subject to the conditions set out in Appendix 2. Decided Open
4 Jul 2019 Maesbrook Nursing Home, Church Road, Shrewsbury - 19/01132/FULThat planning permission be granted as per the Officer’s recommendation subject to the conditions set out in Appendix 1. Decided Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies