21/00312/FUL - Wimpy, 40B - 42 Marine Parade, Southend on Sea (Kursaal Ward)

Approved Planning 6 papers

Development Control Committee approved this item on Wednesday 7 July 2021. Below is the council's own wording, with the papers it was decided on.

Item120

Resolved

- That planning permission be GRANTED subject to the following conditions: General Conditions 01 The development hereby permitted shall begin no later than three years from the date of this decision. Reason: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990. 02 The development hereby approved shall be carried out in accordance with the approved plans: 4083_L01, 4083_PL01, 4083_PL02, 4083_PL03, 4083_PL04, 4083_PL05, 4083_PL06, 4083_PL07, 4083_PL08, 4083_PL09, 4083_PL10. Reason: To ensure the development is carried out in accordance with the development plan. Design and Related Conditions 03 Notwithstanding the details shown on the plans submitted and otherwise hereby approved the development hereby permitted shall not commence, other than for site preparation works, unless and until full details and specifications of the materials to be used for all the external surfaces of the proposed building at the site including facing materials, roof detail, windows (including sections, profiles and reveals), doors, balustrading, fascia and balconies have been submitted to and approved in writing by the local planning authority. The works must then be carried out in full accordance with the approved details before the dwellings hereby approved are first occupied. Reason: In the interest of visual amenity in accordance with the National Planning Policy Framework (2019), Core Strategy (2007) Policies KP2 and CP4, Development Management Document (2015) Policies DM1 and DM3, and the advice contained within the National Design Guide (2019) and the Design and Townscape Guide (2009). Living Conditions 04 The use of the ground floor unit shall be solely within Use Class E as defined within the Town and Country Planning (Use Classes) Order 1987 as amended. Reason: To determine the scope of the permission in the interest of the character and functionality of the area in accordance with the National Planning Policy Framework (2019), Core Strategy (2007) Policies KP2 and CP1, Development Management Document (2015) Policies DM10, DM11 and DM12 and Southend Central Area Action Plan (2015) Policies DS1 and PA1. 05 The hours of operation of the ground floor commercial unit shall be 7 am to 11 pm. Reason: In the interest of the living conditions of future occupiers in accordance with the National Planning Policy Framework (2019), Policies KP2 and CP4 of the Core Strategy (2007), Policies DM1 and DM3 of the Development Management Document (2015). 06 Prior to the first use of the commercial unit hereby approved, a detailed vibration and noise assessment shall be submitted to and approved in writing by the Local Planning Authority. The assessment shall include vibration and noise mitigation measures where needed along with a verification of their effectiveness on site after they have ... view the full minutes text for item 120.
Word for word from the decision Southend-on-Sea published for this meeting. Source: democracy.southend.gov.uk

Follow this further

Built from Southend-on-Sea's papers

What the report saysPro

Report to Development Control Committee

Southend Borough Council Development Control Report Application Ref: 21/00312/FUL

Reference: 21/00312/FUL

Application Type: Full Application

Ward: Kursaal

Proposal: Demolish upper floors, erect three storey building over existing ground floor restaurant to form 9no. self-contained flats with balconies to rear and associated bin and cycle storage

Address: Wimpy, 40B - 42 Marine Parade, Southend-On-Sea

Applicant: [name removed]: [name removed] of Dovetail Architects Ltd

Consultation Expiry: 1st April 2021

Expiry Date: 4th June 2021

Case Officer: Spyros Mouratidis

Plan Nos: 4083_L01, 4083_PL01, 4083_PL02, 4083_PL03, 4083_PL04, 4083_PL05, 4083_PL06, 4083_PL07, 4083_PL08, 4083_PL09, 4083_PL10

Supporting Documents: Design & Access Statement, Flood Risk Sequential Test Assessment, Flood Risk Assessment 2614/RE/12-20/01, Transport Statement 2007980-01, Environmental Noise and Noise Impact Assessment LA/1729/02R/ML

Recommendation: GRANT PLANNING PERMISSION subject to conditions Southend Borough Council Development Control Report Application Ref: 21/00312/FUL

1 Site and Surroundings

1.1The site is located on the northern side of Marine Parade, at its junction with a private road, locally known as Strutt Way, within the central seafront of Southend and it is occupied by a part single, part two and part four-storey building. At ground floor there is currently a restaurant (Wimpy) and the upper floors are partially used by the restaurant and partially as an existing residential unit. The entirety of the site is hardsurfaced or developed and there is no car parking provision. Access to the site is available from its frontage, from Hartington Road to the west via an alleyway and the private unnamed road to the east.

1.2To the north, there are residential properties, with Jubilee Cottages being nearer to the site. To the east and west there are commercial properties with offices or residential units above. Marine Parade in this area has a town centre character with many leisure and commercial uses at ground floor level. On the opposite side of Marine Parade there is public open space and the beach.

1.3The area is within the designated Central Seafront Policy Area according to the Southend Central Area Action Plan. The site and its vicinity are within Flood Zone 3. The building at the western end of the parade, the Cornucopia Public House, is a locally listed building. In the vicinity of the site there is also another locally listed building, the Falcon Public House, and a Grade II statutory Listed Building, the Hope Hotel.

2 The Proposal

2.1Planning permission is sought for the enlargement of the upper floors of the building to accommodate nine (9no.) self-contained flats over three-storeys, including the loft space. The existing upper floors would be demolished to make way for the proposal. The built form above the ground floor on site would be extended to measure up to 16.8m deep at first floor and up to 15.3m deep above by up to 14.1m wide. The proposed roof would have a maximum height of 13m, the same maximum height of attached neighbouring buildings. The rear part of the proposed upper floors would accommodate terraces and balconies. The materials to be used on the proposed development would match the eternal appearance of those already in use on site.

2.2The proposal would result in the loss of the commercial use at first floor level and part of the rear of the ground floor, creating a smaller commercial unit. The existing apparatus on the roof of the ground floor would be removed to accommodate the residential part of the development. The proposed housing mix would include three studio units, five flats with one bedroom and one flat with two bedrooms. The three flats facing towards the north would benefit from terraces and a balcony. Access to the upper floors would be taken from the rear part of the site. Bin storage and nine cycle parking spaces would be provided to the rear.

3 Relevant Planning History

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
21/00312/FUL: Wimpy, 40B: 42 Marine Parade, Southend on Sea (Kursaal Ward)Report 448 KB DownloadRead as text
PDF
existing elevationsReport 283 KB Download
PDF
existing floor planReport 243 KB Download
PDF
existing site planPlan 323 KB Download
PDF
existing street sceneReport 243 KB Download
PDF
loc planReport 322 KB Download

At this meeting

Whole meeting

Who was there

18 of 24 attended
NW
Councillor Nick WardChair, present
AD
Councillor Alan DearVice-Chair, present
JB
Councillor Jennifer BeckCommittee Member, present
KB
Councillor Kevin BuckCommittee Member, present
DC
Councillor Daniel CowanCommittee Member, apologies, sent representative
TC
Councillor Tricia CowdreyCommittee Member, present as substitute
MD
Councillor Matt DentCommittee Member, present
FE
Councillor Fay EvansCommittee Member, present
DG
Councillor Denis GarneCommittee Member, present
DG
Councillor David GarstonCommittee Member, present
SH
Councillor Stephen HabermelCommittee Member, present
DJ
Councillor Derek JarvisCommittee Member, present

All 24 on the meeting page

More from Southend-on-Sea Development Control Committee

All decisions
MeetingDecisionOutcome
30 Apr 2025 Minutes of the Meeting held on Wednesday, 2nd April, 2025- That the Minutes of the Meeting held on Wednesday 2 nd April 2025 be confirmed as a correct record and signed. Decided Open
30 Apr 2025 25/00280/AMDT - Garages at Eagle Way, Shoeburyness (Shoeburyness Ward)That PLANNING PERMISSION be GRANTED subject to the following conditions: 01 The development hereby being amended shal... Approved Open
30 Apr 2025 25/00167/FUL - 18 Brightwell Avenue, Westcliff-on-Sea (Westborough Ward)- That PLANNNG PERMISSION be REFUSED for the following reason: 01 The proposed development would result in room 3 bei... Refused Open
30 Apr 2025 25/00358/FUL - 19 Blatches Chase, Eastwood (Blenheim Park Ward)- That PLANNING PERMISSION be REFUSED for the following reasons: 01 The development introduces types and levels of no... Refused Open
30 Apr 2025 TPO 5/2024 - Land Between 89 - 91 Alexandra Road, Southend-on-Sea (Milton Ward)- That Tree Preservation Order 05/2024 be confirmed. Decided Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies