DC/097900 - Lundy Site & Former Heaton Lane Car Park Site, Stockport

Decided Planning 6 papers

AI summaryStockport planning committee grants five-year temporary permission for a split-site bus depot on the Lundy Site and former Heaton Lane Car Park, to clear the way for 435 flats in the Stockport 8 regeneration.

AI summaryIn plain English

Written from the decision and the officer reportPDF Pro
OutcomeDecidedFive-year period, subject to conditions
MoneyNot stated
What happens nextCentral Area Committee views to followComments to be reported separately
Who it affectsStockport Town Centre bus operationsRelocates depot to enable Stockport 8 Plot 1

What was decided

Temporary planning permission was granted for five years, subject to conditions, for a bus depot (Sui Generis) with bus washing, refuelling, office accommodation, access and drainage works across the Lundy Site and the former Heaton Lane Car Park. Report P3, P9

The proposal includes demolition of buildings on the Lundy Site, open storage of about 83 buses on the Heaton Lane site and 65 buses on the Lundy site, with temporary two-storey offices, drive-through bus wash, refuelling bays and tanks, and three-metre paladin fencing. Report P14, P15, P20, P21, P18, P23

The permission is a departure from Core Strategy policy SD-6 on surface water drainage, requiring it to be decided by the borough-wide Planning and Highways Regulation Committee. Report P6

Why

The temporary depot is needed to free the existing bus depot site so Plot 1 of the Stockport 8 regeneration, comprising three buildings with 435 new apartments and ground-floor commercial space, can be delivered later this year. Report P10

In the longer term, the bus depot is expected to be permanently relocated within the borough to a new purpose-built facility capable of servicing an electric fleet. Report P11

The Highway Engineer, National Highways, Transport for Greater Manchester, Network Rail, Manchester Airport Safeguarding Authority and the Environment Agency raised no objection, subject to conditions including contamination remediation, drainage, lighting, travel plan, EV charging and construction management. Report P92, P101, P155, P158, P163, P165, P167, P175

What happens next

Conditions require a remediation strategy, verification report, drainage details, Travel Plans using the TfGM Toolkit, a Demolition and Construction Management Plan, Travel Plan, EV charging, cycle parking, and access and gate management details before development commences or sites are brought into use. Report P94, P97, P133, P138, P153, P159, P160, P161, P162

The applicant must apply to United Utilities for a trade effluent permit for bus-washing facilities and investigate surface water discharge options in line with the drainage hierarchy. Report P183, P182

Comments and decision of the Central Area Committee will be reported separately. Report P7

Options considered

  • Chosen: Grant temporary planning permission for five years subject to conditions (officer recommendation). Needed to allow Stockport 8 Plot 1 to proceed; consultees raised no objection subject to conditions; loss of car parking and residual highway impact acceptable. Report P10, P125, P155
  • Rejected: Defer for further information on parking, access and layout (initial Highway Engineer view). Subsequent Response Note and revised drawings addressed the concerns, leading the Highway Engineer to withdraw the objection. Report P140, P142, P155

Implications

  • Legal: Application is a departure from the development plan in respect of surface water drainage under Core Strategy policy SD-6, so it had to be decided by the Planning and Highways Regulation Committee. Report P6
  • Environment and climate: Two mature London Plane trees on the Heaton Lane site and six other low quality or dead trees would be lost; the Lundy Site has little vegetation beyond a laurel hedge. Biodiversity Net Gain and ecology surveys were submitted. Report P17, P30, P36, P187
  • Environment and climate: The Lead Local Flood Authority says the drainage strategy does not follow the hierarchy and is not policy compliant; 50% reduction in surface water discharge is sought and the applicant must justify any move to lower-priority discharge options. Report P177, P179, P184
  • Environment and climate: The Environment Agency requires a remediation strategy and verification report because the sites have a high to medium risk of contamination over a principal aquifer connected to a nearby watercourse. Report P88, P89, P92, P94, P97
  • Risk: Manchester Airport Safeguarding Authority requires capped horizontal lighting, no reflective materials, dust and smoke management during construction, and measures to avoid attracting birds, in the interests of flight safety. Report P167, P168, P170, P171, P173
  • Transport: The sites together would accommodate 148 double-decker buses, 39 car parking spaces including disabled bays, 4 motorcycle spaces and 20 cycle spaces per site, with 3 EV chargers at Heaton Lane and 4 at Lundy (17% provision). Report P119, P120, P121, P153
  • Transport: Buses would run to and from the Stockport Interchange via Great Egerton Street, Heaton Lane, Kingston Street, Chestergate, King Street West, Daw Bank and the Heaton Lane roundabout, adding roughly one extra vehicle every four minutes at peak times on the most affected streets. Report P110, P112
  • Other: Gough Street (adopted highway) is proposed to be gated to secure staff parking; closure of part of the street may require a Traffic Regulation Order or Stopping Up Order rather than section 247 of the Town and Country Planning Act 1990. Report P24, P149
  • Other: A single objection was received from a member of the public concerned about traffic, noise, air quality, loss of amenity and the risk of a temporary five-year use becoming semi-permanent. Report P75, P77, P78, P79

Who and where

  • Bus operators and depot staff, who would relocate from the existing King Street West depot to the two temporary sites Report P105, P110
  • Stockport 8 LLP, the applicant, which needs the bus depot to move to start Plot 1 (435 apartments) Report P4, P10
  • Residents and businesses near Great Egerton Street, Heaton Lane, Kingston Street, Chestergate, King Street West, Daw Bank and the Heaton Lane roundabout, who would see more bus and staff traffic Report P110, P77
  • Town centre car park users, because the permanent loss of remaining surface-level parking at Heaton Lane is now built into the redevelopment Report P123, P125
  • The Grade II listed Hollywood Park Centre, which shares a brick boundary wall with the Lundy Site Report P23, P32

Timeline

  • 12.01.2026: Application registered Report P4
  • 9th February 2026: Highway Engineer's initial consultation response recommending deferral Report P140, P142
  • 2026-03-19: Planning and Highways Regulation Committee grants five-year temporary permission subject to conditions
  • Five years from permission: End of the temporary permission period; longer-term relocation to a permanent, electric-fleet depot envisaged Report P9, P11
  • 13.04.2026: Application expiry date Report P4

Plain English for the jargon

  • Sui Generis: A planning use class for uses that do not fall within any standard use class, here meaning a bus depot.
  • MSCP: Multi-storey car park; the former Heaton Lane MSCP was recently demolished, leaving a largely level site.
  • TTRO: Temporary Traffic Regulation Order, a council order that can temporarily close or restrict use of a road such as Gough Street.
  • Section 247 (T&CPA 1990): Power allowing a council to stop up a highway to enable development, which the Highway Engineer doubts can be used for Gough Street.
  • BNG: Biodiversity Net Gain, a planning policy requirement that development leaves the natural environment in a better state than before.
  • SSSI Impact Risk Zone: A buffer around a Site of Special Scientific Interest where certain developments must consult Natural England; the application site is within one but this use is not relevant to the designation.
What was decided, why, and what happens next

Pro reads every officer report for you and explains each decision in plain English: the money, the options, the risks, the timeline, each with the paragraph it came from.

Written by AI from the council's published papers. AI can get things wrong: the council's own wording below is the record.Report a problem
Item5.(ii)

Resolved

RESOLVED - That temporary planning permission be granted for a five-year period subject to conditions
Word for word from the decision Stockport published for this meeting. Source: democracy.stockport.gov.uk

Follow this further

Built from Stockport's papers

What the report saysPro

Report to Planning & Highways Regulation Committee

ITEM 2

Application DC/097900 Reference Location: Lundy Site & Former Heaton Lane Car Park Site Stockport SK3 0BQ

PROPOSAL: Full planning application for demolition of buildings on Lundy Site, temporary use of Lundy Site and Former Heaton Lane Car Park Site as bus depot (Sui Generis) with associated buildings, including bus-washing and office accommodation for five years, together with access, drainage and associated works.

Type Of Full Application Application: Registration 12.01.2026 Date: Expiry Date: 13.04.2026 Case Officer: Daniel Hewitt Applicant: The Stockport 8 LLP Agent: Deloitte LLP

DELEGATION/COMMITTEE STATUS

Departure from the development plan in respect of surface water drainage Core Strategy policy SD-6. The application can therefore only be approved by the borough wide Planning and Highways Regulation Committee.

Due to committee dates, the decision / comments of Central Area Committee will be reported separately.

DESCRIPTION OF DEVELOPMENT

Temporary planning permission is sought for a five-year period for the “demolition of buildings on Lundy Site, temporary use of Lundy Site and Former Heaton Lane Car Park Site as bus depot (Sui Generis) with associated buildings, including bus- washing and office accommodation…together with access, drainage and associated works”

The rationale for the development is to enable the delivery of Plot 1 of the Stockport 8 development to progress later this year on the site of the current bus depot. Plot 1 of Stockport 8 involves the erection of three buildings comprising 435 new apartments and ground floor commercial space surrounded by extensive, landscaped public realm. Members will be aware that Stockport 8 is of strategic significance for the ongoing regeneration of the Town Centre.

In the longer term, the bus depot(s) would be permanently relocated elsewhere in the borough in a new, purpose-built facility capable of supporting and servicing an electric fleet.

The proposed development is best understood by reference to the submitted plans. The proposals are split across two sites. Each one is briefly described below:

Former Heaton Lane Car Park site

It is proposed to use this site to openly store circa. 83 buses when not in active use. Ancillary supporting buildings and structures on this site include:

 a temporary two storey office building;  bus and external chassis washes;  refuelling bays and tanks; and  plant/storage buildings and structures.

Access would be from Heaton Lane with egress onto Great Egerton Street.

Currently, there are pockets of trees and soft landscaping on the site’s boundaries and two, mature, medium quality, London Plane trees occupying a central position which would be lost to development along with six other low quality or dead trees.

The site would be further enclosed by three metre high paladin mesh style fencing where necessary.

Former Lundy Site

Following demolition of all remaining buildings on the site, it is proposed to openly store 65 buses on hardstanding when not in active use. Ancillary supporting buildings and structures on this site include:

 a temporary two storey office building;  drive thru bus wash  refuelling bays and tanks; and  plant/storage buildings and structures.

Access and egress would be from Kingston Street with a secondary access from Gough Street leading to 21 staff car parking bays. A further two disabled bays would be located on the northeastern corner of the site, accessed from Kingston Street.

The site would be enclosed by three metre high paladin mesh style fencing where necessary with the existing brick boundary wall separating the site from the adjacent Grade II listed Hollywood Park Centre building forming the western boundary.

It is proposed that Gough Street (adopted highway) be gated to provide security for staff parking facilities.

SITE AND SURROUNDINGS

The proposals are split across two sites. Each site is briefly described below:

Former Heaton Lane Car Park site

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
DC/097900: Lundy Site & Former Heaton Lane Car Park Site, StockportReport 584 KB DownloadRead as text
PDF
DC097900 Temp Bus Depots CAC Update (ii)Report 117 KB Download
PDF
Enc. 2 for DC/097900 Temporary Bus Depots (ii)Report 5.9 MB Download
PDF
Enc. 3 for DC/097900 Temporary Bus Depots (ii)Report 2.2 MB Download
PDF
Enc. 4 for DC/097900 Temporary Bus Depots (ii)Report 1.1 MB Download
PDF
Enc. 5 for DC/097900 Temporary Bus Depots (ii)Report 1 MB Download

At this meeting

Whole meeting

Who was there

11 of 13 attended
SG
Councillor Steve GribbonChair, apologies
RW
Councillor Rachel WiseVice-Chair, in the Chair, present
AC
Councillor Asa CatonCommittee Member, present
AC
Councillor Anna Charles-JonesCommittee Member, present
LC
Councillor Liz CrixCommittee Member, present
WD
Councillor Will DawsonCommittee Member, present
DF
Councillor Dean FitzpatrickCommittee Member, present
SG
Councillor Sue GlitheroCommittee Member, present
GG
Councillor Graham GreenhalghCommittee Member, present
IH
Councillor Ian HunterCommittee Member, present
MN
Councillor Mike NewmanCommittee Member, present
SW
Councillor Suzanne WyattCommittee Member, present

All 13 on the meeting page

On this subject at Stockport

Search all
  1. DC/097900 - Lundy Site & Former Heaton Lane Car Park Site, StockportThis decision
  2. DC/097900 - Lundy Site & Former Heaton Lane Car Park Site, StockportDecided

More from Stockport Planning & Highways Regulation Committee

All decisions
MeetingDecisionOutcome
19 Mar 2026 DC094376 - Stockport 8, Land At Town Centre West, Stockport, SK3 0DURESOLVED – That planning permission be granted subject to conditions and the completion of a legal agreement securing... Agreed Open
19 Mar 2026 Planning Appeals, Enforcement Appeals and Enforcement NoticesRESOLVED - The report be noted. Noted Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies