(8 votes to nil) To grant planning permission on application P15/V2274/FUL, subject to the following conditions: 1. Time limit – three years. 2. Approved plans. 3. The use of the test facility shall be restricted to 08:00hrs to 18:00hrs Monday to Friday only and shall not take place at any other time including public holidays. 4. Vehicular access to and from the site shall be taken only from Avon Road, as shown on the submitted access plan number A017 and the existing access point from Upper Farm Road shall be kept locked at all times except for emergency access. 5. All construction traffic shall only enter and exit the site via Avon Road, as shown on the submitted access plan number A017; and construction shall take place in accordance with the submitted construction traffic management plan dated 2 December 2015. Informative: All wild birds and their nests receive protection under the Wildlife and Countryside Act 1981 (as amended) which makes it illegal to intentionally take, damage or destroy the nest of any wild bird while it is in use or being built. Therefore in order to avoid contravention of this legislation, any site works likely to affect potential bird nesting habitat should be timed to avoid the main bird nesting season which runs from mid-March to July. If this is not possible, a check should be carried out prior to any clearance works to ensure there are no active nests present.
Word for word from the decision Vale of White Horse published for this meeting.Source: democratic.whitehorsedc.gov.uk
Farfield Antenna Test Facility for Satellite Applications Catapult
Location and block plan
Appendix 1 AL(0)A016
Location plan scale September 2015
1.2500 @A3
Wrigley Associates
1.2500 1m 5m 10m 20m
0 50m 100m
A016 30 Alexandra Road Lyncombe Bath BA2 Hill 4PW Tel: 01225 337420 Fax: 01225 337467 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 DRAWING NO. TITLE Locations Key Revision Revision date Revision notes LAYOUT OF THE FAR FIELD TEST RANGE 15058.COM.A010 DESCRIPTION Easting Northing Latitude Longitude OS Grid 1 21/08/2015 Moved storage cabins; comments; Upper Farm trees CLIENT NAME PROJECT NO.
Rx Tower 447762 185677 51.567947 -1.3123003 SU 47762 85677 Existing taxiway and hardstanding Buildings 2 25/08/2015 Title changed; houses added; scale; sheet size SAC 15058 P ISSUE REVISION P Rx Storage Cabin 447771 185699 51.568147 -1.3121621 SU 47771 85699 3 04/09/2015 Tower pos'ns; extra detail view A014; extended path for Tx Preliminary 4 DATE DRAWN Rx Storage Cage 447771 185699 51.568147 -1.3121621 SU 47771 85699 Line of sight; duct detail; annotations 4 07/09/2015 18/08/2015 20' ISO Container 447771 185699 51.568147 -1.3121621 SU 47771 85699 Boundaries Vehicle access DRAWN BY
A. Aljo Car Park 447757 185710 51.568250 -1.3123653 SU 47757 85710 CHECKED BY
Tx Cabin 447409 185726 51.568418 -1.3173857 SU 47409 85726 SCALE SHEET SIZE Roads Line of sight 1:2000 A2 SHEET NO.
N N PART NO. Trees Palisade fencing N/A MATERIAL
N/A TYPE
N/A FINISH
Refer to drawing
M M Unit 18 Notley Farm, Chearsley Road Long Crendon, Aylesbury Buckinghamshire HP18 9ER United Kingdom
T: +44 (0) 1844 208 363 E: [email removed] k ar Par thC COMMENTS
Sou 1. Do not scale this drawing. L 2. All dimensions in mm L unless otherwise stated.
Appendix 2 3. All material to be grade Detail A Scale 1:500 S275J0 or S355J0 (or J2), in compliance with BS 10025. Rx Storage Cabin 4. All metalwork, including fasteners, to be hot-dip galvanized to BS EN 1416. Rx Storage Cage 5. All fasteners to be minimum grade 8.8, in 20' ISO Container compliance with BS 4190, and supplied with a K Car Parking square section spring K een washer and full nut. 6. Minimum hole clearance Fift
for fasteners should be 1mm greater than the ad
See Note 1 nominal fastener Ro
diameter. 7. No thermal cutting to be To
used in process. All parts to be laser-cut where possible, including bolt holes. Laser-cutting is not Palisade Fence a 'thermal-cutting' J process. J Rx Tower & Cabin
Ch ilto Existing taxiway to be cleared of
nF H H vegatation overgrowth to provide access
iel where necessary
d m 4 .8 70 1 G 1 A01 G
Detail A
To Transmit (Tx) Receive (Rx)
Up Line of sight: ca Detail B Scale 1:10 bin centres ap
per 100mm buried prox. 400m Earth covering duct to follow
Far same line - Det Earth to be backfilled A012 cross-se ail B
mR F ction F Power cable laid direct Turf to be removed, stored
oad and reinstated Warning tape
95 100mm duct
.61 4 A01
E m E
rm r Fa
500 p pe U
d D m Roa D Far Upper
C C
B B
100.07 m 1:2000 Scale bar 200m @ A2
5m 25m 50m 100m
A A
All rights reserved. Copyright Site One Ltd. 2015
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 DRAWING NO. TITLE Revision Revision date Revision notes LONG SECTION THROUGH THE RANGE 15058.COM.A011 DESCRIPTION 1 21/08/2015 Positioner; contoured to Chilton Field; scale change P CLIENT NAME PROJECT NO. P 2 25/08/2015 Title; antenna pole; distances SAC 15058 ISSUE REVISION
3 04/09/2015 Show increased distance; change in height Preliminary 3 DATE DRAWN
18/08/2015 DRAWN BY
A. Aljo N CHECKED BY N
SCALE SHEET SIZE
1:2000 A3 SHEET NO.
PART NO.
M N/A M MATERIAL
N/A TYPE
N/A FINISH
Refer to drawing
L L
+132.5m Unit 18 Notley Farm, Chearsley Road Long Crendon, Aylesbury
+122.6m +122.6m Buckinghamshire HP18 9ER United Kingdom
Approx. 400m Approx. 190-195m T: +44 (0) 1844 208 363 E: [email removed] K K
1:2000 Scale bar 200m @ A3 COMMENTS
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.