Resolved
to defer application P17/V1154/LB for listed building consent for further investigations to take place into the technical impacts of flooding as a result of track lowering.
Planning Committee deferred this item on Wednesday 9 May 2018. Below is the council's own wording, with the papers it was decided on.
Resolved
to defer application P17/V1154/LB for listed building consent for further investigations to take place into the technical impacts of flooding as a result of track lowering.
This expert opinion is prepared by Ing. Martin Solka of Solka Engineering GmbH. I was trained as an electrification engineer by the Austrian Federal Railways (Österreichische Bundesbahnen or ÖBB, with a tradition of main line electrification going back over 100 years). Between 2002 and 2016 I have worked on internbational electrification projects for Balfour Beatty Rail GmbH, including extensive electrication of existing heavy railways in Austria (2002-2007). I have worked as Deputy Project Leader on the electrical aspects of the new Gotthard Base Tunnel and connections (2010-2016) (design speed 250km/h) and between 2007 and 2010 as Project Manager (Electrification) for the 1000km High Speed Line frpm Wuhan to Guangzhou (China) (design speed 350km/h). Since 2014 I have been the representative of Balfour Beatty Rail GmbH on the CENELEC Working Group for OCL Standard EN50119: Railway applications. Fixed installations. Electric traction overhead contact lines (the European stanadard on which Network Rail base their BS EN 50119). I thus have extensive experience of electrification projects like the Great Western Main Line as well as experience of evolving and implementating relevant international standards.
After considering all received technical specifications and safety-related standards and laws we can confirm that the suggested OCR solution of a solid conductor rail beneath a retained bridge will fulfil the all criteria and standards for a good quality of current collection for the dynamic interaction between pantograph and OCL for an operation speed of 160 km/h (100mph) (the EU and UK standard limit for un-manned level crossings such as those at Steventon).
Solka Engineering understand that a derogation exists that allows trains to pass the Steventon level crossings at an elevated speed of up to 200 km/h (125mph). Because of the facing and trailing points where the railway changes from 2 tracks to four at Steventon and the distance to / from the station and junctions at Didcot Parkway station, the likelihood of any trains passing Steventon at speeds significantly greater than 160 mk/h (100mph) is considered low, even with the benefits of electrification. With the excellent characteristics of the BR Brecknell Willis High Speed pantograph (specified for the new Hitachi class 800 and 801 IEP bi-mode fleet constructed for fleet operation of this route) and its record of safe use at speeds of up to 250km/h (150mph) on non-TSI-compliant routes electrified before the introduction of the TSI (notably the UK East Coast and West Coast Main Lines) it should be possible to derrogate the contact wire gradient to allow for speeds significantly in excess of 160 mk/h (100mph), if needed.
Page 3 of 20 Doc.-No.: SE-00014
Alternatively, it should normally prove possible to carry out: • a track-lower to make bigger the clearances under the Steventon bridge or over the Stocks Lane level crossing; • use a neutral section of contact wire /rail under the bridge or over the Stocks Lane level crossing to allow for reduced clearances (considered in the TUC report); • to derogate for reduced clearances in the way that the Steventon level crossings are already derogated for higher speeds than are permitted by UK and EU standards • To provide for reduced clearances over the Stocks Lane level crossing using a physical barrier, signs and ‘cow bells’ and / or • To raise the Steventon bridge through jacking.
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
PDF |
P17/V1154/LB: Steventon Overbridge, High Street ,Steventon: AppendicesReport | 6.3 MB | DownloadRead as text |
PDF |
P17/V1154/LB: Steventon Overbridge, High Street ,SteventonReport | 478 KB | Download |
Follow Planning Committee at Vale of White Horse and we tell you when its next papers are published, before the meeting rather than after it.
| Meeting | Decision | Outcome | |
|---|---|---|---|
| 16 Sep 2026 | P24/V2434/HH - 4 Raleigh Park Road, North Hinksey, Oxford, OX2 9AZto approve planning application P24/V2434/HH subject to the conditions set out in the report. | Approved | Open |
| 16 Sep 2026 | P25/V2033/FUL - 1 The Green, Drayton, Abingdon, OX14 4JAto approve planning application P25/S2033/FUL subject to the conditions set out in the report and in the update provi... | Approved | Open |
| 16 Sep 2026 | P25/V1947/O - Signia Park, Land at former Didcot A Power Station, Purchas Road, Didcotto approve planning application P25/V1947/O subject to the conditions set out in the report. | Approved | Open |
| 22 Jul 2026 | Minutesto approve the minutes of the meeting held on 10 June 2026 as a correct record and agree that the Chair sign these as... | Approved | Open |
| 22 Jul 2026 | P26/V0815/HH - 42 Harding Way, Marcham, Abingdon, OX13 6FJto approve planning application P26/V0815/HH subject to the following conditions: 1. Commencement within three years ... | Approved | Open |
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Keeps you signed in and runs your free-paper allowance. Always on.
Counts visits and which pages are used. First-party only, no advertising, never shared.