RESOLVED : to grant grant listed building consent for application P20/V1847/LB, subject to the following conditions; 1. Commencement of works within three years 2 Works in accordance with the approved plans 3. Materials in accordance with details submitted 4. Tile hanging in accordance with submitted details
Word for word from the decision Vale of White Horse published for this meeting.Source: democratic.whitehorsedc.gov.uk
Cromwell House Leylandii Cromwell House House 1 to 9 1 Leylandii 4
House 1 to 9 1 Builder's
Yard 4 135 121 127 125 to 131 129 133 141 143 145 to 157
Shelter ET OCK STRE 51.9m
148 156 152 176 170 154
192 190
188 186
Builder's ABINGDON Yard
135 121 127 125 to 131 129 133 141 143 145 to 157
Shelter E ET OCK STR SITE LOCATION PLAN 1:1250 51.9m
148 156 152 176 170 154
162 GENERAL NOTES:
190 DO NOT SCALE. ALL DIMENSIONS TO BE CHECKED ON SITE AND ANY 192 186 DISCREPANCIES REPORTED IMMEDIATELY. LOCATION OF ALL SERVICES (ABOVE & BELOW GROUND) TO BE 188 FULLY VERIFIED BEFORE COMMENCEMENT. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL CONSULTANTS & SPECIALISTS DRAWINGS WHERE RELEVANT AND ANY DISCREPANCY BETWEEN THIS INFORMATION AND OTHER DRAWINGS FORMING PART OF THE CONTRACT TO BE CLARIFIED BEFORE COMMENCEMENT OR ORDERING OF MATERIALS. THE COPYRIGHT OF THE DRAWINGS & DESIGN IS THE BLOCK/SITE PLAN 1:500 PROPERTY OF THE COMPANY AND UNAUTHORISED REPRODUCTION IS PROHIBITED. ALL ELEMENTS TO BE INSTALLED STRICTLY IN ACCORDANCE WITH MANUFACUTRERS INSTRUCTIONS AND RELEVANT CURRENT LEGISLATION, BUILDING REGULATIONS, BRITISH STANDARDS AND GOOD PRACTICE.
project title scale date Richard J Exley 133 OCK STREET, ABINGDON, OXON BLOCK & SITE 500, 1250 JULY'18 Architectural Services LOCATION PLANS client dwg.no. rev 9 High Street, Eynsham, Oxford, OX29 4HA E: [email removed] T: [phone removed] MR M THOMPSON 467-AL09 - proposed conservation proposed conservation rooflight (Velux A3 proposed conservation rooflights (Velux CK06) CK04) rooflight (Velux CK04) Appendix 1 (2 of 8)
SIDE (EAST) REAR (NORTH)
proposed existing gable end structural framing to be conservation repaired as SWJ Engineer's rooflight (Velux recommendations (refer to drawing 00652 - CK04) 00300 rev T1)
existing verge tiles/slates adjusted to suit
vertical clay plain tile hanging externally (refer to drawing 467-AL20a for details)
code 4 lead flashing at junction of cladding and existing plain tiled coping
SIDE (WEST) REV F - 2no. CK01 ROOFLIGHTS CHANGED TO CK04 - SEPT'20 REV E - VERTICAL TILE HANGING IN LIEU OF WEATHERBOARDING TO GABLE - AUG'20 REV D - GABLE WORKS ADJUSTED - AUG'20 ELEVATIONS - PROPOSED REV C - GABLE WORKS ADDED - JULY'20 REV B - ROOFLIGHTS ADJUSTED - OCT'19 REV A - ROOFLIGHTS ADJUSTED - SEPT'19
project title scale date Richard J Exley 133 OCK STREET, ABINGDON, OXON ELEVATIONS - 100 JULY'18 Architectural Services PROPOSED client dwg.no. rev 9 High Street, Eynsham, Oxford, OX29 4HA E: [email removed] T: [phone removed] MR M THOMPSON 467-AL08 F proposed new loadbearing partitions in roof space spanning between existing trusses to provide additional support to existing roof structure - refer to SWJ A3 proposed new loadbearing partitions in Consulting drawings - note- existing ceiling raised to extg ceiling joists roof space spanning between existing VOID rafters to be supplemented with new underside of upper removed locally trusses to provide additional support to Appendix 1 (3 of 8)
47x75 C24 rafters @ 400c/c where struts over shower existing roof structure - refer to SWJ required proposed Consulting drawings - note- existing proposed extg ceiling joists rafters to be supplemented with new conservation conservation left exposed 47x75 C24 rafters @ 400c/c where rooflight (Velux rooflight (Velux CK04) required CK04)
proposed partition proposed partition SHOWER insulate VOID between LANDING 47x147mm C24 extg truss BEDROOM 1 joists @ 400c/c if members approx 1775mm extg proves headroom under CUP'D inadequate extg soil pipe raised to ceiling void extg purlin to serve new shower rooms and terminated with an AAV
BEDROOM 1 HOBBIES SECTION B-B proposed partition
BEDROOM 2 LANDING relative level of hobbies room to proposed be confirmed conservation note- extremely low headroom extg shower room floor rooflight (Velux
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.