Resolved
That planning application 0233/FUL relating to the Former Railway Hotel, 1 Station Road, Parbold be approved subject to the conditions and reasons as set out on pages 514 to 519 of the Book of Reports and with the amendment to Conditions 2 and 11 and an additional condition as set out on pages 538 to 539 of the Late Information Report and with an additional condition as set out below:- Additional Condition 23. No development shall take place until a strategy for the separate foul and surface water drainage of the development, including any necessary attenuation measures, has been submitted to and approved in writing by the Local Planning Authority. The surface water drainage strategy must take account of the relevant provisions of this councils Planning Applications - Drainage, Flood Risk and Sustainability guidance and the Non-Statutory Technical Standards for Sustainable Drainage Systems (March 2015) or any subsequent replacement standards. The drainage scheme shall be completed in accordance with the approved details. Surface water discharge from the new development shall be restricted to 3.0 l/s for all rainfall events up to and including 1 in 100 year plus an allowance of 35% for climatic change. The MicroDrainage mdx file, if available, is required to aid the checking of design calculations. Reason: To ensure adequate drainage for the proposed development and to ensure that there is no flood risk on- or off-the site resulting from the proposed development and to ensure that the development complies with the provisions of Policy GN3 in the adopted West Lancashire Local Plan 2012-2027 Development Plan Document.