Resolved
Resolved That planning permission be granted, and that the Head of Planning be authorised to issue the decision notice, subject to the completion of a Section 106 agreement to secure financial contributions towards the provision and maintenance of off site open space and cycling/and or walking infrastructure, and to conditions, inter alia including the following:- T003 Outline Planning Permission T004 Outline Planning Permission(2) H003 Visibility Splays H011 Parking – Estate Development H018 On Site Roads - Submission of Details H019 On Site Roads – Phasing H021 Wheel washing H027 Parking for Site Operatives Z001 The development hereby approved shall not exceed 6 dwellings. Reason: In the interests of highway safety. Z002 The new estate road junction onto Birmingham Road , B4085, shall be provided with 6 metre entrance radii and 5.5 metre wide carriageway for a distance of at least 20 metres from the nearside edge of the Birmingham Road carriageway. Thereafter the estate road carriageway shall be at least 4.5 metres wide and its alignment shall comply with the requirements of the County Council's document, "Highway Criteria, Policy and Layouts for New Developments". Reason: In the interests of highway safety. Z003 Notwithstanding the note on the deposited plan a minimum 1.8 metre wide footway shall be provided across the frontage of the application site. In addition the internal estate road shall be laid out to accord with the current standards of the Highway Authority. Reason - In the interests of highway safety. Z004 Floor levels should be set at least above the road level at 31.20 metres above Ordnance Datum. Reason - To protect the development from flooding. Z005 There must be no new buildings, structures (including gates, walls and fences) or raised ground levels within 8 metres of the top of any bank of the Littleton Brook, along the boundary of the site, unless agreed otherwise in writing by the Local Planning Authority. Reason: To maintain access to the watercourse for maintenance or improvements and provide for overland flood flows. Z006 No development approved by this permission shall be commenced until a scheme for the improvement and/or extension of the existing surface water sewerage system has been submitted to and approved in writing by the Local Planning Authority. No buildings hereby permitted shall be commenced until such improvements and/or extensions have been commissioned to the satisfaction of the Local Planning Authority. Reason - To provide adequate drainage. NOTE: In order to comply with the above condition, the applicant must demonstrate that they have entered into a suitable agreement with the Sewerage Undertaker which will also provide for the works to be undertaken within the lifetime of this permission. Z007 The detailed drawings to be submitted for approval under reserved matters shall include a topographical survey of existing ground levels contoured at 0.5 metre intervals, together with details of proposed finished levels. Reason: To enable the Local Planning Authority to assess the effects of the proposed development on flood defence/land drainage. Z008 There shall be no storage of ... view the full minutes text for item 226.