The approval be granted subject to the conditions listed in the report. Reason: The proposed development of the floodlights to the existing tennis court is considered due to its siting and design to not harm the openness of the Green Belt or the purposes of including the application site within the general extent of the Green Belt. The proposal is also considered to be acceptable in terms of the impact on the street scene, the impact on the character of the adjacent conservation area, highway safety and on local ecology. With regard to residential amenity, subject to conditions regarding lighting levels, restricting the use of the floodlights to no later than 2000 hours and to the use as tennis only, the proposal is considered acceptable.
Word for word from the decision York published for this meeting.Source: democracy.york.gov.uk
Date: 4 July 2019 Ward: Rural West York Team: Major and Parish: Upper Poppleton Parish Commercial Team Council
Reference: 19/00186/FUL Application at: Poppleton Community Centre Main Street Upper Poppleton York YO26 6JT For: Installation of 8 no. floodlights at Poppleton Lawn Tennis Club. By: [name removed]: Full Application Target Date: 28 June 2019 Recommendation: Approve
1.0PROPOSAL
1.1The application site is the existing outdoor tennis courts at Poppleton Community Centre, located to the south west of Main Street, Upper Poppleton. The site forms part of an area containing a number of community and leisure facilities including a children's play area, community centre and also Poppleton Ousebank Primary School and Library. There are two sets of tennis courts at the site and this application is for the courts in the north east corner of the site, adjacent to Main Street.
1.2Opposite the site to the east are residential dwellings along Main Street. The children's play area is north west of the courts and the Poppleton Community Centre is to the south west. A lawn bowls green lies to the south east. There are existing floodlights to the other tennis courts at the site.
1.3Planning permission is sought for the erection of 8 no floodlights to the tennis courts. The pylons for the floodlights will measure eight 8 metres in height and will floodlights will consist of twelve lamps in total, with one lamp fitted to each corner pylon and two lamps fitted to the central pylons.
1.4The application was called in for determination at Planning Committee by the local ward member at the time Councillor Steward , who shared the concerns raised by local residents with regard to light and noise pollution
2.0POLICY CONTEXT
2.1Yorkshire and Humber Regional Spatial Strategy (saved policies)
YH9(C) Green Belts Y1 (C1 and C2) York Area sub area policy Application Reference Number: 19/00186/FUL Item No: 4d Page 1 of 12 2.2 Poppleton Neighbourhood Plan
PNP1 Green Belt Policy PNP4 Village Design Statement
2.32018 Publication Draft Local Plan
GB1 Development in the Green Belt HW3 Built Sport Facilities D1 Placemaking D2 Landscape and Setting D4 Conservation Areas GI2 Biodiversity and Access to Nature ENV2 Managing Environmental Quality
3.0CONSULTATIONS
INTERNAL
Highways Network Management
3.1No objection
Public Protection
3.2From the report the levels suggested at the nearest residential properties are maximum surface illuminance of 2.35 lux and maximum intensity cd 509. I would advise that the area is classed are Environmental zone E3 and therefore if the maximum surface illuminance is 2.35 lux and maximum intensity cd 509, then provided the lights are off by 2300 hours these levels would be acceptable. I would however request confirmation from the applicant that my interpretation of their report in terms of these levels at the nearest receptors is correct.
Design Conservation and Sustainable Development (Ecology)
3.3In reviewing the flood lighting scheme I have referred to guidance produced by the Institution of Lighting Professionals and the Bat Conservation Trust (Bats and artificial lighting in the UK, 2018).
3.4The proposed scheme is based on eight 8 metre columns and twelve 2kW Philips Optivision MVP507 using the 2kW MHN metal halide lamp, with a colour temperature of 4500K. Technical information on the lighting has been provided which shows the
Application Reference Number: 19/00186/FUL Item No: 4d Page 2 of 12 illuminance (lux) levels, at ground level. In terms of wildlife this shows fairly significant light spill beyond the edge of the tennis courts.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.