Planning, Protective Services and Licensing Committee approved this item on Thursday 11 March 2004. Below is the council's own wording, with the papers it was decided on.
Decision 1. To approve the Standards for Licensing of Houses in Multiple Occupation in Argyll and Bute. 2. To acknowledge that this is part of Legal and Protective Services strategy to meet the targets imposed on all Councils by the Scottish Executive to significantly increase the number of licensed houses multiple occupation on Scotland. (Reference: Report by head of Legal and Protective Services dated 11 March 2004).
Word for word from the decision Argyll and Bute published for this meeting.Source: www.argyll-bute.gov.uk
Report to Planning, Protective Services and Licensing Committee
LEGAL AND PROTECTIVE SERVICES
STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION AND SHARED ACCOMMODATION 2 STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION
INTRODUCTION
Since 1 October 2000, all local authorities in Scotland have been required to licence houses in multiple occupation (HMOs). A house in multiple occupation is one occupied by more than two persons as their only or principal residence where those persons are members of more than one or two families. Houses which are otherwise separate but are within the same building and which share a toilet or personal washing facilities or cooking facilities are to be taken as forming a single house.
LEGISLATION
The legislation governing licensing of HMOs can be found in the Civic Government (Scotland) Act 1982 and the Civic Government (Scotland) Act 1982 (Licensing of Houses in Multiple Occupation) Order 2000.
STANDARDS
These standards will apply to all licensable HMOs in Argyll & Bute. Owners of HMOs should note that, in addition to these standards, they should ensure that they have received all necessary consents and permissions under planning and building control legislation.
In determining whether a particular House in Multiple Occupation offers an acceptable level of accommodation it may be possible to achieve an equivalent level of accommodation or safety that may be acceptable to the Licensing Authority.
The Council will require that alterations be carried out to existing premises so as to ensure compliance with these standards. A time scale for carrying out such alterations will be at the discretion of the Council’s Head of Legal & Protective Services.
3 STANDARDS APPLICABLE TO HOUSES IN MULTIPLE OCCUPATION
1. Natural Lighting
1.1All bedrooms and living rooms must have adequate natural lighting by means of an aggregated area of clear glazing equal to at least 1/15th of the floor area of the room. This shall be situated in an external wall or roof, or in a wall between a room and a conservatory.
1.2Where practicable, all kitchens, bathrooms, water closets, staircases, landings and passageways should also have adequate natural lighting. Where this is not practicable, suitable and sufficient artificial lighting must be provided in accordance with Standard 2.
2. Artificial Lighting
2.1Suitable and sufficient electrical lighting must be provided to all parts of the premises having a floor area of 2 square metres or more, providing at least one lighting point to each area. All electrical wiring and fittings shall be maintained in a safe condition.
2.2On any staircase, artificial lighting must have controlling switches at each landing.
3. Ventilation
3.1All bedrooms and living rooms must be ventilated directly to the external air by window, or rooflights, the opening area of which shall be equivalent to at least 1 /30th of the floor area.
3.2Where practicable all kitchens, bathrooms and water closets shall open to the external air as stated in Standard 3.1 but, where this is not practicable, mechanical ventilation must be provided based on the following requirements :-
(a) Air changes of a minimum of 15 litres/second for bathrooms, water closets and washrooms;
(b) Air changes of a minimum of 60 litres/second for kitchens.
(c) Air changes of a minimum of 30 litres/second in utility rooms.
Such /….
4 Such systems shall be fitted with a time-delay switch, operated from the lighting circuit of the room.
Fan noise from the extraction system should be inaudible within the bedrooms of the property.
3.3Where a single room is used for sleeping, living and cooking purposes, the above Standards 3.1 and 3.2 shall be complied with, in addition to the requirement for the natural and mechanical ventilation being effective in removing cooking odours from the room to the external air.
4. Space Standards
4.1(a) Where the accommodation is bedroom only with a communal living room and shared kitchen from which meals are prepared, the size of the bedroom shall be a minimum of :-
Follow Planning, Protective Services and Licensing Committee at Argyll and Bute and we tell you when its next papers are published, before the meeting rather than after it.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.