CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Argyll and Bute Council
Planning, Protective Services and Licensing Committee, Wednesday 18 January 2017 at 10.30am

MR JONATHAN BARTON: ERECTION OF HOUSE IN MULTIPLE OCCUPATION, INSTALLATION OF SEWAGE TREATMENT PLANT, AIR SOURCE HEAT PUMP AND FORMATION OF VEHICULAR ACCESS: LAND EAST OF NANT FARM, ICHRACHAN, TAYNUILT (REF: 16/02861/PP)

Agreed Planning 2 papers

Planning, Protective Services and Licensing Committee agreed this item on Wednesday 18 January 2017. Below is the council's own wording, with the papers it was decided on.

Item12

Resolved

Decision The Committee agreed to grant planning permission as a minor departure from Policies LDP DM 1 and SG LDP HOU 1 subject to the following conditions and reasons:- 1. Approved Drawings & General: The proposed development shall be carried out in accordance with the details specified in the application form dated 18/03/16 and the approved drawings numbered: • Plan 1 of 2 (1575 05 rev E) • Plan 2 of 2 (1575 01 rev A) and stamped approved by Argyll and Bute Council. Reason: In order to ensure that the proposed development is carried out in accordance with the details submitted and the approved drawings. 2. Sewage Treatment Tank and Soakaway: No development shall commence on site until full details of the proposed means of private foul drainage to serve the development and five other family sized residential units have been submitted to and approved by the Planning Authority. The duly approved scheme shall be implemented in full concurrently with the development that it is intended to serve and shall be operational prior to the occupation of the development. Reason: To ensure that an adequate means of foul drainage is available to serve the development. 3. Sustainable Urban Drainage System (SuDS): No development shall commence on-site until details of a Sustainable Urban Drainage System (SUDS) are submitted to and approved in writing by the Planning Authority. Such details shall include a drainage layout plan which shall include any mitigation measures required to address surface water run-off from the development site. The development thereafter shall be completed in accordance with the approved details prior to the initial occupation of the house hereby approved. Reason: To ensure that there is a satisfactory drainage system in place for the development, in the interests of health and amenity and environmental protection. 4. Availability of Connection to Public Water Supply: No development shall commence on site until authorisation has been given by Scottish Water for connection to the public water supply. Confirmation of authorisation to connect shall be provided in writing to the Planning Authority before commencement of development. Reason: To ensure that the development is adequately served by a public water supply. 5. Sample Materials: No development shall commence on site until samples of materials and colour finishes to be used in the external finishes of the building have been submitted to and approved in writing by the Planning Authority. The development shall thereafter be completed and maintained using the approved materials and colours or such alternatives as may be agreed in writing with the Planning Authority. Reason: In order to integrate the development into its surroundings. 6. Landscape/Surface/Boundary Treatment: No development shall commence on site until a scheme of boundary treatment, surface treatment and landscaping has been submitted to and approved in writing by the Planning Authority. The scheme shall include details of: i) Location, design and materials of proposed walls, fences and gates; ii) Surface treatment of proposed means of access and hardstanding areas; iii) Any proposed re-contouring of the site by means of existing and proposed ground levels. iv) Proposed hard and soft landscape works. The development shall not be occupied until such time as the boundary treatment, surface treatment and any re-contouring works have been completed in accordance with the duly approved scheme. All of the hard and soft landscaping works shall be carried out in accordance with the approved scheme during the first planting season following the commencement of the development, unless otherwise agreed in writing by the Planning Authority. Reason: To assist with the integration of the proposal with its surroundings in the interest of amenity. 7. Visibility Splays: The existing vehicular access at the junction of the existing public road shall have visibility sightlines of 2.4m x 42m x 1.05m in both directions and shall be constructed in accordance with Argyll and Bute Council Small Development Guide Drawing no. SD 08/004 rev a. This shall include a surface water drainage system to prevent water spilling onto the public road. Reason: In the interests of road safety. 8. Parking and Turning Facilities Prior to the occupation of the development hereby approved the parking and turning detailed on drawing no. 1575 05 Rev E shall be available for use and retained thereafter. Reason: In order to ensure that there are acceptable ... view the full minutes text for item 12.
Word for word from the decision Argyll and Bute published for this meeting. Source: www.argyll-bute.gov.uk

Follow this further

Built from Argyll and Bute's papers

What the report saysPro

Report to Planning, Protective Services and Licensing Committee

Argyll and Bute Council Development & Regulatory Services

Delegated or Committee Planning Application Report and Report of handling as required by Schedule 2 of the Town and Country Planning (Development Management Procedure) (Scotland) Regulations 2013 relative to applications for Planning Permission or Planning Permission in Principle ____________________________________________________________________________

Reference No: 16/02861/PP

Planning Hierarchy: Local Application

Applicant: [name removed]: Erection of house in multiple occupation, installation of sewage treatment plant, air source heat pump and formation of vehicular access

Site Address: Land East Of Nant Farm, Ichrachan, Taynuilt

____________________________________________________________________________

DECISION ROUTE

(i) Local Government Scotland Act 1973

____________________________________________________________________________

(A) THE APPLICATION

(i) Development Requiring Express Planning Permission

Development Requiring Express Planning Permission

 Erection of House for Multiple Occupation (6 bedrooms)  Formation of vehicular access  Formation of on-site car parking and associated servicing and turning area  Installation of sewage treatment plant and associated soakaway  Installation of air sourced heat pump

(ii) Other specified operations

• Connection to existing public water supply ____________________________________________________________________________

(B) RECOMMENDATION:

It is recommended that planning permission be approved as a minor departure from policies LDP DM1 and SG LDP HOU1 subject to the attached conditions and reasons. ____________________________________________________________________________

(C) HISTORY:

It is clear from the objections received to this application that this site has a complex planning history. Indeed in objecting to this application a number of residents have expressed concern over what they consider the lack of clarity on the process of determining previous applications. Residents have also separately written to the Head of Planning and Regulatory Services outside the application process to seek further clarity and reassurance on previous determinations and procedural matters related to the various proposals for the site.

It is felt that to reassure and inform both Members and Objectors a more detailed officer commentary explaining the planning history of the site and clarifying what has happened in the past would be a beneficial before evaluating the merits of the current planning application. This planning history and commentary is set out below:

14/01889/PREAPP – Pre-Application inquiry for residential re-development of farm complex (seven units).

Advice was sought on redeveloping the farm complex, which sits within the settlement boundary, for residential purposes. The response to this was generally favourable and advice to this effect was provided by the Area Team Leader at that time. His comments, by e-mail dated 18.9.14, were that:

“I confirm that the redevelopment of the site for housing is worthy of support in principle. The physical features on the ground are such that I recommend only six units are proposed. The trees and the raised bracken covered knoll at the north end of the site combine to rule out plot 4. Assuming the overhead line crossing plot 3 is realigned, the other six plots could all be supported in principle”.

16/00265/PP – Erection of dwellinghouse for use as House of Multiple Occupancy- withdrawn 18.3.16

The withdrawal of this application is related to the description of development being incorrect. I clarify this in more detail below:

An e-mail from the agent on 5.2.16 states: I’ve just realised that I called this a ‘house’ when technically it should have been ‘house of multiple occupancy’, sorry but any chance the description could be changed please? Thanks.

The e-mail withdrawing this application states: Further to recent discussions I confirm that we would like to withdraw this application. Thank you.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
2861 plan, 09/01/2017 Pre-Agenda Briefing of the Planning, Protective Services and Licensing CommitteeAgenda 276 KB Download
PDF
MR JONATHAN BARTON: ERECTION OF HOUSE IN MULTIPLE OCCUPATION, INSTALLATION OF SEWAGE TREATMENT PLANT, AIR SOURCE HEAT PUMP AND FORMATION OF VEHICULAR ACCESS: LAND EAST OF NANT FARM, ICHRACHAN, TAYNUILT (REF: 16/02861/PP)Report 217 KB DownloadRead as text

At this meeting

Whole meeting

Who was there

11 of 15 attended
RH
Rebecca HepburnSecretary, expected
DK
Councillor David KinniburghChair, present
GB
Councillor Gordon BlairMember, apologies
RC
Councillor Rory ColvilleMember, present
RC
Councillor Robin CurrieMember, present
GF
Councillor George FreemanMember, present
AM
Councillor Alistair MacDougallMember, present
NM
Councillor Neil MacIntyreMember, present
RG
Councillor Robert Graham MacIntyreMember, present
DM
Councillor Donald MacMillanMember, present
RM
Councillor Roderick McCuishMember, present
AM
Councillor Alex McNaughtonMember, apologies

All 15 on the meeting page

More from Argyll and Bute Planning, Protective Services and Licensing Committee

All decisions
MeetingDecisionOutcome
15 Sep 2026 Beaufort wind limited: erection of 7 turbines (up to 149.9m to tip) and ancillary development and decommissioning of existing beinn ghlas wind farm: existing beinn ghlas wind farm, taynuilt (ref: 25/01240/pp)Decision The Committee agreed to grant planning permission subject to the following conditions and reasons: 1. PP - A... Agreed Open
15 Sep 2026 Mr tony coogan: alterations to guesthouse to facilitate lawful use of existing roof space as ancillary guest house owner's accommodation: greencourt, benvoullin road, oban (26/00434/pp)Decision The Committee agreed to grant planning permission subject to the following conditions and reasons: Standard ... Agreed Open
15 Sep 2026 Mrs faulkes: proposed alterations and erection of extension: 30 the green, craobh haven (ref: 26/01009/pp)Decision The Committee agreed to grant planning permission subject to the following conditions and reasons: Standard ... Agreed Open
15 Sep 2026 Scottish power renewables/machair wind limited: scottish government's marine directorate section 36 consultation on proposed machair offshore wind farm: site 15 km north west of isle of islay and 12.4 km west of isle of colonsay (ref: 26/01100/s36)Decision The Committee agreed that the Scottish Government’s Marine Directorate should be notified that Argyll and Bu... Agreed Open
15 Sep 2026 Development management performance update - fq1 2026/27Decision The Committee reviewed and agreed the content of the report. (Reference: Report by Executive Director with r... Agreed Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies