CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Bracknell Forest Council
Planning & Highways Committee, Thursday 26 April 2007 at 7.30pm

PS 07/00242/FUL - 3 Vulcan Way Sandhurst

Refused Planning 1 paper

Planning & Highways Committee refused this item on Thursday 26 April 2007. Below is the council's own wording, with the papers it was decided on.

Item150

Resolved

RESOLVED that the application be refused for the following reasons:- The proposal would lead to an increase in noise, disturbance and exhaust fumes arising from the additional traffic movements associated with the change of use, within a surrounding residential area and as such would be detrimental to the amenities of the occupiers of neighbouring residential properties. The proposal is therefore contrary to Policies EN5 of the Berkshire Structure Plan and EN20, EN25 and E2 of the Bracknell Forest Borough Local Plan. The traffic generated by the proposal would by reason of the increase in the levels and type of vehicle associated with the use travelling through residential areas, be detrimental to the safe movement of users of the highway and as such would be detrimental to vehicle and pedestrian safety. The proposal is therefore contrary to Policies T1 and T4 of the Berkshire Structure Plan and E2 of the Bracknell Forest Borough Local Plan.
Word for word from the decision Bracknell Forest published for this meeting. Source: democratic.bracknell-forest.gov.uk

Follow this further

Built from Bracknell Forest's papers

What the report saysPro

Report to Planning & Highways Committee

ITEM NO: 10 Application No. Ward: Date Registered: Target Decision Date: 07/00242/FUL Little Sandhurst And 12 March 2007 7 May 2007 Wellington Site Address: 3 Vulcan Way Sandhurst Berkshire GU47 9DB Proposal: Application for the change of use from Light Industrial (Class B1c) to transportation depot (Sui Generis use) with ancillary offices and workshop. Siting of diesel storage tank and addition of razor wire increasing height of fencing on north east boundary to 2.95m. Applicant: Mts Cleansing Services Ltd Agent: Emberson & Co Case Officer: John Devonshire, 01344 352000 [email protected]

Site Location Plan (for identification purposes only, not to scale)

© Crown Copyright. All rights reserved. Bracknell Forest Borough Council 100019488 2004

Planning & Highways Committee 26th April 2007 1 RELEVANT PLANNING HISTORY (If Any)

06/01110/FUL Validation Date: 08.12.2006 Application for the change of use from General Industrial (Class B2) to transportation depot (Sui Generis use) with ancillary offices and workshop. Siting of diesel storage tank and addition of razor wire increasing height of fencing on north east boundary to 2.95m. Withdrawn

2 RELEVANT PLANNING POLICIES

Key to abbreviations BSP Berkshire Structure Plan 2001 – 2016

BFBLP Bracknell Forest Borough Local Plan BFBCS Core Strategy Development Plan Document (Submission) RMLP Replacement Minerals Local Plan WLP Waste Local Plan for Berkshire SPG Supplementary Planning Guidance SPD Supplementary Planning Document

RPG Regional Planning Guidance RSS Regional Spatial Strategy (also known as the South East Plan)

PPG (No.) Planning Policy Guidance (Published by DCLG) PPS (No.) Planning Policy Statement (Published by DCLG) MPG Minerals Planning Guidance DCLG Department for Communities and Local Government

Note: The BSP and the BFBLP contain some policies with the same title, e.g. EN1. In such cases, the policy will be suffixed with an “_S” for the BSP and an “L” for the BFBLP, e.g. EN1_S, EN1L..

Plan Policy Description (May be abbreviated) BSP DP1 Spatial Strategy BSP EN5_S Air Pollution And Nuisance BFBLP EN20 Design Considerations In New Development BFBLP EN22 Designing For Accessibility BFBLP EN25 Noise And Other Pollution BFBLP E2L Development In Defined Employment Areas BFBLP M9 Vehicle And Cycle Parking BFBCS CS20 New Development in Employment Areas 3 CONSULTATIONS (Comments may be abbreviated)

Transportation Officer

(No comments received at time of producing this report).

Environmental Health

Planning & Highways Committee 26th April 2007 No objections subject to the following conditions: -

- HGV's shall depart no earlier than 06.30 and return no later then 19.00, with no movements overnight or on Sundays and Bank Holidays.

- The workshop shall operate from 06.30 to 19.00 hours only, with no works on Sunday or Bank Holidays.

- Noise associated with works shall remain within the confines of the premises. No noisy works shall take place outside the workshop

- Any lighting shall ensure that pooling effect from lights is kept within site curtilage.

- The above ground diesel tank must incorporate 110% bund of the storage capacity. Suitable barriers on the three exposed sides must be incorporated in the design to prevent vehicles damaging the bund or the tank. The bund shall be constructed so diesel does not peculate into the land and any rain water accumulated within it can be removed appropriately.

The Environment Agency

No objection to the proposals, but recommend that informatives are added to any planning permission granted in order to protect controlled waters.

Sandhurst Town Council

(No comments received at time of producing this report).

4 REPRESENTATIONS

10 letters of objection have been received with the following comments: -

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
PS 07/00242/FUL: 3 Vulcan Way SandhurstReport 124 KB DownloadRead as text

At this meeting

Whole meeting

Who was there

9 of 11 attended
DW
David Worrall CONChair, present
RE
Councillor Robert Edger OBE CONVice-Chair, present
AB
Councillor Alan Browne CONCommittee Member, present
CD
Councillor Colin Dudley CONCommittee Member, present
JF
Jim Finnie CONCommittee Member, present
DH
Councillor Dorothy Hayes CONCommittee Member, present
LJ
Langdon Jones LABCommittee Member, present
SR
Mrs Shelagh R Pile CONCommittee Member, present
CT
Clifton Thompson CONCommittee Member, absent
OV
One VacancyCommittee Member, expected
AF
Alvin Finch CONSubstitute, present as substitute

On this subject at Bracknell Forest

Search all
  1. PS 07/00242/FUL - 3 Vulcan Way SandhurstThis decision
  2. 07/00700/FUL - 3 Vulcan Way, SandhurstRefused

More from Bracknell Forest Planning & Highways Committee

All decisions
MeetingDecisionOutcome
26 May 2011 11/00123/FUL - 29 Essex Rise, Warfield, BracknellRESOLVED that the application be refused for the following reason:- 01. The proposed extension by reason of its desig... Refused Open
26 May 2011 11/00177/FUL - 25 Branksome Hill Road College Town SandhurstThe following development plan policies have been taken into account in determining this planning application: Brackn... Decided Open
26 May 2011 PS 11/00239/RTD - Land Opposite Byways Crowthorne Road SandhurstRESOLVED that the siting and appearance of the development proposed be refused for the following reason: 1. The propo... Refused Open
26 May 2011 11/00308/RTD - Land Adjacent To Electricity Substation, Victoria Road, OwlsmoorRESOLVED that the siting and appearance of the development proposed be approved in accordance with the plans as state... Approved Open
25 May 2011 Election of chairmanRESOLVED that Councillor Dudley be elected Chairman of the Planning and Highways Committee for the Municipal Year 201... Decided Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies