Durham County Council

APPLICATIONS - BOROUGH MATTERS PDF 200 K

Agreed Planning

Development Control Committee (SBC) agreed this item on Friday 28 April 2006. Below is the council's own wording, with the papers it was decided on.

Item167

Resolved

RESOLVED : 1. That in respect of Application No. 2 - Erection of New Industrial Unit - Park 2000, Millennium Way, Heighington Lane Business Park - David Newett - Audby Grange, Audby Lane - Plan Ref : 7/2006/0097/DM - Conditions 2, 3, 4 and 7 detailed in the schedule be deleted and the following conditions be included :- i. If the course of new development reveals previously unknown contamination, then no further development shall be carried out without an agreement in writing from the Local Planning Authority. Reason: To ensure that the development complies with details to protect Controlled Waters. ii. Prior to being discharged into any watercourse, surface water sewer or soakaway system, all surface water drainage from parking areas and hardstandings shall be passed through trapped gullies installed in accordance with a scheme previously submitted to and approved in writing by the Local Planning Authority. Reason: To prevent pollution of the water environment. iii. Any facilities for the storage of oils, fuels or chemicals shall be sited on impervious bases and surrounded by impervious bund walls. The volume of the bunded compound should be at least equivalent to the capacity of the tank plus 10%. If there is multiple tankage, the compound should be at least equivalent to the capacity of the largest tank, or the combined capacity of interconnected tanks, plus 10%. All filling points, vents, gauges and sight glasses must be located within the bund. The drainage system of the bund shall be sealed with no discharge to any watercourse, land or underground strata. Associated pipework should be located above ground and protected from accidental damage. All filling points and tank overflow pipe outlets should be detailed to discharge downwards into the bund. Reason: To prevent pollution of the water environment. 2. That the remainder of the recommendations detailed in the schedule be adopted.
Word for word from the decision Durham published for this meeting. Source: democracy.durham.gov.uk

Follow this further

Built from Durham's papers

Papers for this item

Kept in our archive, download once signed in

No papers were published with this item. The decision above is the council's full record of it.

At this meeting

Whole meeting

On this subject at Durham

Search all
  1. APPLICATIONS - BOROUGH MATTERS PDF 200 KThis decision
  2. Applications - borough matters pdf 11 mDeferred
  3. Applications - borough matters pdf 606 kApproved
  4. Applications - borough matters pdf 23 mApproved
  5. Applications - borough mattersDeferred
  6. Applications - borough matters pdf 1 mApproved

More from Durham Development Control Committee (SBC)

All decisions
MeetingDecisionOutcome
6 Mar 2009 Applications - borough matters pdf 11 mRESOLVED : That the application be deferred pending further discussions. Application 2 - Outline Application for Busi... Deferred Open
6 Mar 2009 Applications - county mattersRESOLVED : That the recommendations detailed in the report be approved. Approved Open
6 Mar 2009 Delegated decisions pdf 68 kRESOLVED : That the schedule be received. Decided Open
6 Mar 2009 Appeals pdf 47 kRESOLVED : That the schedule be received. Decided Open
6 Mar 2009 Town and country planning act 1990 - cornforth conservation area - revised conservation area character appraisal and cornforth conservation area management plan pdf 58 kRESOLVED : That the Committee approve the revised Cornforth Conservation Area Character Appraisal and management plan. Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies