East Devon District Council
Planning Committee, Tuesday 22 August 2023 at 9.30am

23/1124/MFUL (Major) YARTY

Refused Planning 1 paper

Planning Committee refused this item on Tuesday 22 August 2023. Below is the council's own wording, with the papers it was decided on.

Item45

Resolved

Refused contrary to officer’s recommendation. Members considered that: 1. The proposal was not considered to be a renewable or low carbon energy project as there is no evidence that it would be used to store energy from low carbon sources and therefore represents inappropriate development in the countryside. Furthermore it would have a harmful impact on the landscape character and quality of the area when considered in combination with other installations in the locality and would therefore be contrary to Strategy 7 (Development in the Countryside), Strategy 39 (Renewable and Low Carbon Energy Projects) and Strategy 46 (Landscape Conservation and Enhancement and AONBs) of the East Devon Local Plan 2013 - 2031. 2. It would lead to a loss of best and most versatile agricultural land and if so whether there is an overriding need for the development, sufficient land of a lower grade is available that could accommodate the development or the benefits of the development justify the loss of the high grade agricultural land. As a result the development is considered to be contrary to policy EN13 (Development on High Quality Agricultural Land) of the East Devon Local Plan 2013 - 2031. 3. There was insufficient information on the health and safety measures that would be put in place to control battery leakages and fire that could arise in the event of a failure at the site and as a result it is considered that the development could lead to a significant health and safety risk to residents that would be contrary to policy EN14 (Control of Pollution) of the East Devon Local Plan 2013 -2031.
Word for word from the decision East Devon published for this meeting. Source: democracy.eastdevon.gov.uk

Follow this further

Built from East Devon's papers

What the report saysPro

Report to Planning Committee

Ward Yarty

Reference 23/1124/MFUL

Applicant C/o Agent

Location Pound Road Bess Land North East Of Axminster National Grid Substation Pound Road Hawkchurch

Proposal The installation of a battery energy storage system with associated infrastructure and works.

RECOMMENDATION: Approval with conditions

Crown Copyright and database rights 2023 Ordnance Survey 100023746 Committee Date: 22.08.2023

Yarty Target Date: (Hawkchurch) 23/1124/MFUL 24.08.2023

Applicant: C/o Agent

Location: Pound Road Bess Land North East Of Axminster National Grid Substation

Proposal: The installation of a battery energy storage system with associated infrastructure and works.

RECOMMENDATION: Approval with conditions

The above planning application was considered at Planning Committee on 18 July 2023. The application was deferred to allow further consultation with Devon and Somerset Fire and Rescue Service (DSFRS), in particular to ask how they would deal with a fire at the application site.

The response from DSFRS , received on 27/7/2023 is as follows:

This letter offers comment on the Safety Management Plan that the applicant has included under the above consultation which is a 'Second Go' application of 22/2216/MFUL.

Furthermore, this letter addresses specific issues that have been raised, including those made in a Rule 6 Party's Statement of Case under application 22/2216/MFUL. East Devon District Council Planning Authority (EDDC) have requested that Devon and Somerset Fire and Rescue Service (DSFRS) provide comments in relation to Issue 2 and Issue 3 of the Rule 6 Party's Statement of Case.

Safety Management Plan

Planning Application 23/1124/MFUL introduces a Safety Management Plan (SMP) that has been prepared for the applicant by Abbott Risk Consulting Limited.

The aim of the SMP is to 'define the safety strategy, requirements, and processes necessary to meet agreed safety objectives and to set a level of safety performance that the system is to be measured against.'

To meet these aims, the document specifies that a strategy to reduce risk to as low as reasonably possible (ALARP) will be employed and that a primary objective of the project will be to comply with all applicable legal requirements and relevant emerging good practice.

23/1124/MFUL In terms of strategy implementation, the SMP goes onto state that a 'layered protection approach' will be provided and lists some of the mitigation requirements that can be employed to reduce fire risk, such as remote monitoring, container segregation and suppression systems.

Unfortunately, the level of detail provided in the document is limited and as such DSFRS is not able to provide much in the way of constructive commentary. The explanation provided in the SMP, in that detail cannot be provided until suppliers, contractors and specific equipment is selected, partially justifies the limited detail but there are also issues on which the document could have provided more detail. For example, there is limited or no commentary on deflagration prevention and venting, space separation between units, emergency access and firefighting water supplies. The SMP refers to a System Requirement Document (SRD), where it is presumed these matters will be discussed in more detail. However, it is not specified when or whether consultation on the SRD will be offered to stakeholders, or indeed what stakeholders may contribute. Similarly, the SMP mentions a BESS Safety Working Group (SWG) that will be responsible for the oversight of BESS safety management. However, once again there is no detail regarding who will form the SWG and by what mechanisms they will review and oversea the safety management of the project.

Therefore, it is DSFRS' opinion that the aims initially set out by the SMP have not been fully met. Nevertheless, DSFRS does view the applicant's commitment, as stated in the SMP, to comply with applicable legal requirements and good practice positively.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
23/1124/MFUL (Major) YARTYReport 2.3 MB DownloadRead as text

At this meeting

Whole meeting

Who was there

12 of 27 attended
BB
Councillor Brian BaileyCommittee Member, present
IB
Councillor Ian BarlowCommittee Member, present
CB
Councillor Colin BrownCommittee Member, present
AB
Councillor Alasdair BruceCommittee Member, present
SC
Councillor Sarah ChamberlainVice-Chair, apologies
SG
Councillor Steve GazzardCommittee Member, present
AH
Councillor Anne HallCommittee Member, present
JH
Councillor John HeathCommittee Member, present
MH
Councillor Mike HoweCommittee Member, apologies
YL
Councillor Yehudi LevineCommittee Member, present
HR
Councillor Henry RiddellCommittee Member, present
ER
Councillor Eleanor RylanceCommittee Member, apologies

All 27 on the meeting page

On this subject at East Devon

Search all
  1. 23/1124/MFUL (Major) YARTYThis decision
  2. 26/0535/MFUL (Major) WHIMPLE & ROCKBEAREApproved
  3. 25/0965/MFUL (Major) WHIMPLE & ROCKBEARERefused
  4. 24/0841/MFUL (Major) HONITON ST PAULSRefused
  5. 25/2397/MFUL (Major) & 25/2398/LBC EXMOUTH TOWNApproved
  6. 25/1259/MFUL (Major) HONITON ST MICHAELSApproved

More from East Devon Planning Committee

All decisions
MeetingDecisionOutcome
1 Sep 2026 25/2471/MRES (Major) CRANBROOKApproved with conditions in accordance with officer recommendation. Approved Open
1 Sep 2026 26/1143/PIP (Other) CLYST VALLEYThe Appropriate Assessment be adopted. 2. Permission in Principle be approved. Approved Open
1 Sep 2026 26/0854/FUL (Minor) BROADCLYSTApproved with conditions in accordance with officer recommendation. Approved Open
1 Sep 2026 26/0534/MOUT (Major) WHIMPLE & ROCKBEAREThe Appropriate Assessment be adopted. 2. Approved with conditions in accordance with officer recommendation subject ... Approved Open
1 Sep 2026 26/0535/MFUL (Major) WHIMPLE & ROCKBEAREThe Appropriate Assessment be adopted. 2. That the SANGS application be approved, subject to conditions and to the co... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies