CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Gedling Borough Council
Planning Committee, Wednesday 23 June 2021 at 6.00pm

Enforcement Ref. 0031/2021 - Bracken House, Blidworth Waye, Papplewick

Decided Planning 1 paper

Planning Committee decided this item on Wednesday 23 June 2021. Below is the council's own wording, with the papers it was decided on.

Item9

Resolved

That the Head of Development and Place, in conjunction with the Head of Governance and Customer Services, be authorised to take all relevant planning enforcement action including the service of any necessary enforcement notices and issue of proceedings through the courts, if required, to ensure the removal of the unauthorised building and the removal of the fence or alternatively the reduction in the height of the fence to 2m.
Word for word from the decision Gedling published for this meeting. Source: democracy.gedling.gov.uk

Follow this further

Built from Gedling's papers

What the report saysPro

Report to Planning Committee

Background

1.1On 29th September 2020, the Council received a complaint relating to the felling of approximately 40-50 trees that were subject to a Tree Preservation Order at Bracken House, Blidworth Waye, Papplewick. The information received alleged that the trees had been felled in order that the land owner could erect multiple buildings in the same location.

1.2On 9th December 2020 2 officers from the Council visited the site along with an officer from the Forestry Commission in order to assess the allegations relating to the felling of trees. The officers met with the owner of the site and his father.

1.3During the visit the officer noted that there were 2 new buildings on site. One building measured approximately 8 x 6 x 3m that the owner said would be used as a home office. The other measured 15 x 10 x 3.7m that was to be used for a sun room, gym and spa. The officer noted that this building was being built to a very high standard with cavity wall insulation, multiple rooms, windows and doors.

1.4Schedule 2 Part 1 Class E of the General Permitted Development Order 2015 (as amended) (GPDO) grants permission for any building within the curtilage of a dwellinghouse providing it remains incidental to the enjoyment of the dwellinghouse and is within the parameters of Class E including conditions that the height of the building does not exceed 4 metres in the case of a building with a dual pitched roof and the height of the eves does not exceed 2.5m from ground level. The owner insisted the building would comply with the GPDO and that it would be used as a summerhouse, gym and spa.

1.5On 12th and 13th January 2021 the Council wrote to the owner to raise concerns relating to the summerhouse building. It was stated that until the building was complete, the officer could not be satisfied that it would fall within the requirements of the GPDO. It was explained that this was due to the building having the appearance of a small bungalow which could not be constructed without an express planning permission from the Local Planning Authority.

1.6On the 13th April 2021 an officer from the Council visited the site by appointment to inspect the building following its completion. The building had been completed with the exception of some architrave to the internal door frames and the installation of a ceiling mounted projector screen in the main room.

1.7Internally the building comprised a large open space with a kitchen and utility at one end, a separate bathroom and one further separate room. A front and side door had been installed off the kitchen It was noted that the standard of finish was exceptionally high. Marble floor tiles had been laid throughout and the bathroom (comprising twin wash hand basins, walk in shower, low level WC and a freestanding bath) was also fully tiled in marble. The kitchen and utility area was large and the fittings of a very high standard with multiple units and worktops, and several appliances (ovens, hob, fridges etc.). The building had been plumbed with water, had water filled radiators and had been wired with multiple ceiling spotlights and mains powered sockets.

1.8Several pieces of gym equipment were located in the large open space beyond the kitchen area on top of temporary rubber matting laid on top of the marble flooring. Large bi-fold doors had been installed to two elevations of this part of the building, overlooking a new patio. The owner informed the officer that the unfinished wiring hanging from the ceiling was for a ceiling mounted projector.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
Enforcement Ref. 0031/2021: Bracken House, Blidworth Waye, PapplewickReport 330 KB DownloadRead as text

At this meeting

Whole meeting

Who was there

15 of 21 attended
JT
Councillor John TruscottCommittee Member, apologies
PW
Councillor Paul WilkinsonChair, present
MA
Councillor Michael AdamsCommittee Member, present
PB
Councillor Peter BarnesCommittee Member, present
CB
Councillor Chris BarnfatherCommittee Member, present
JC
Councillor Jim CreamerCommittee Member, present
DE
Councillor David EllisCommittee Member, present
AE
Councillor Andrew EllwoodCommittee Member, present
MH
Councillor Mike HopeCommittee Member, present
RK
Councillor Rosa KeneallyCommittee Member, present
ML
Councillor Meredith LawrenceCommittee Member, present
RM
Councillor Ron McCrossenCommittee Member, apologies

All 21 on the meeting page

On this subject at Gedling

Search all
  1. Enforcement Ref. 0031/2021 - Bracken House, Blidworth Waye, PapplewickThis decision
  2. Enforcement ref. 0257/2022 - Nottingham Sun Club, Brackenwood, Newstead Abbey Park, RavensheadDecided
  3. Enforcement ref. 0132/2023 - 22 Onchan Drive, CarltonDecided
  4. Enforcement ref. 0267/2022 - 91 Main Street, Burton JoyceDecided
  5. Enforcement ref: 0105/2023 - Lakeside (Former Bestwood Pumping Station) Mansfield Road, BestwoodDecided
  6. Enforcement ref: 0118/2022 - 15 Woodthorpe Drive, WoodthorpeDecided

More from Gedling Planning Committee

All decisions
MeetingDecisionOutcome
14 Oct 2026 To approve, as a correct record, the minutes of the meeting held on 9 September 2026That the minutes of the above meeting, having been circulated, be approved as a correct record. Approved Open
14 Oct 2026 Application no. 2026/0501 - Richard Herrod Centre, Foxhill Road Central, Carlton, NottinghamshireTo Grant Planning Permission: Subject to the conditions listed for the reasons set out in the report. Conditions The ... Approved Open
14 Oct 2026 Appeal Summary Ref: 6014560 - 31 Mansfield Road, Daybrook, NottinghamshireTo note the information. Noted Open
14 Oct 2026 Appeal Summary Ref: 6013777 - 6 Pateley Road, Woodthorpe, NottinghamshireTo note the information. Noted Open
14 Oct 2026 Future planning applicationsTo note the information. Noted Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies