CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Huntingdonshire District Council
Licensing and Protection Panel, Friday 1 August 2003 at 2.00pm

STATUTORY CONSULTATION FOR LANDFILL PERMIT APPLICATIONS

Decided Licensing 2 papers

Licensing and Protection Panel decided this item on Friday 1 August 2003. Below is the council's own wording, with the papers it was decided on.

Item14

Resolved

RESOLVED (i) that the Council object to the grant of a Permit for hazardous waste in respect of Warboys landfill site, on the grounds set out in the annex to the report now submitted, and (ii) that, after consultation with the Chairman and Vice-Chairman, the Director of Operational Services and the Head of Environmental Health Services be authorised to respond to any future statutory consultation under the Pollution and Prevention Control (England and Wales) Regulations 2000.
Word for word from the decision Huntingdonshire published for this meeting. Source: democracy.huntingdonshire.gov.uk

Follow this further

Built from Huntingdonshire's papers

What the report saysPro

Report to Licensing and Protection Panel

ANNEX

DRAFT CONSULTATION RESPONSE

THE POLLUTION PREVENTION AND CONTROL (ENGLAND AND WALES) REGULATIONS 2000 (SI 2000 No 1973), as amended, (PPC Regulations); THE LANDFILL (ENGLAND AND WALES) REGULATIONS 2002 (SI 2000 No 1559)

Application Reference: BV 2007 – Warboys Landfill Site

Thank you for consulting Huntingdonshire District Council in relation to the above application for a PPC Permit.

As a general statement, the District Council (HDC) does not consider that this site, being close to a residential area and agricultural land, is appropriate for the proposed use. However if the Agency is minded to approve the application HDC is not satisfied that sufficient information has been supplied in the application for it to be confident that adequate protection of public health and the environment will be guaranteed. Specifically, HDC’s concerns are as follows.

HDC’s view is that GasSim is not an appropriate tool for predicting pollutant dispersion from the gas engine, flare stack and fugitive LFG emissions. Additionally, HDC cannot accept the results of dispersion calculations that have been made on the basis of calculated/assumed emissions rather than site-specific measured values.

HDC’s view is that the air quality impact assessment should be resubmitted and should

• Be based on an appropriate modelling package • Use model inputs derived from site specific measurements • Cover several consecutive years of meteorological data • Consider emissions from the gas engine, flare stack and fugitive LFG • Present output data that can be compared directly with National Air Quality Strategy objectives and limit values and long term Environmental Assessment Levels • Consider all pollutants that are currently regulated by air quality objectives and limit values and/or are likely to impact upon public health and/or the environment. (Of particular concern are vinyl chloride and other chlorinated organics, benzene and hydrogen sulphide in the landfill gas) • Consider pollutants that are likely to come into regulation and/or have their air quality limit values reviewed during the lifetime of site operations/after care (4th EUDD and review of the Stage 2 Particle limit value)

HDC’s view is that, because of the extremely high chlorine burden carried in the landfill gas stream there is significant potential for emission and/or reformation of Polychlorinated Dibenzodioxins and Polychlorinated Dibenzofurans. HDC’s view is that this area has not been adequately addressed in the application, and further, HDC is particularly concerned regarding the proposed trigger levels of these compounds given at sections 3.1.9 and 3.1.17 of the application forms, which, HDC believe are too high by a factor of 106. HDC’s view is that because of the carcinogenic potency of these compounds, a monitoring interval of 5 years is far too long and that monitoring should encompass not only emissions but also ambient air and crops/soils at sensitive locations as identified from the results of appropriate dispersion modelling.

HDC has learned from the Environment Agency that the land fill gas being recovered from cells 4a and 4b contains trace contaminants (chlorine and sulphur compounds) at such high concentrations as to prohibit its use for power generation. HDC’s view is that a gas cleaning plant should be installed in order to maximise the use of this renewable energy resource and minimise the release of harmful substances to the environment.

HDC assumes that following completion of landfilling operations and restoration works, there will be a protracted period of after care, involving, among other things, the collection and destruction/utilisation of landfill gas and environmental monitoring. HDC is concerned that there appears to be nothing in the consultation documentation to address the scope and longevity of the after care programme, and further, that there are no triggers or milestones to indicate when cessation of after care may be appropriate.

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
Fenside Consult Response 24.7.03Report 52 KB DownloadRead as text
PDF
STATUTORY CONSULTATION FOR LANDFILL PERMIT APPLICATIONSReport 60 KB Download

At this meeting

Whole meeting
13MINUTESOn the agenda
14STATUTORY CONSULTATION FOR LANDFILL PERMIT APPLICATIONSThis decision

Who was there

8 of 12 attended
RE
Councillor Robert Ernest BarnesVice-Chair, expected
MC
Councillor Mrs Carol Anne Godley, deceasedMember, apologies
DH
Councillor David HartyMember, apologies
AB
Councillor Anthony Bell HulmeMember, present
RP
Councillor Ray PowellMember, apologies
MD
Councillor Mrs Deborah Christine ReynoldsMember, present
JM
Councillor John Michael SadlerChair, present
LM
Councillor Lawrence Michael Simpson(known as Mike)Member, present
JT
Councillor Jack TaylorMember, present
RG
Councillor Richard Graham TuplinMember, present
MN
Councillor Mrs Norah Frances WagstaffeMember, present
JS
Councillor John Samuel WattMember, present

On this subject at Huntingdonshire

Search all
  1. STATUTORY CONSULTATION FOR LANDFILL PERMIT APPLICATIONSThis decision
  2. East west rail - making meaningful connections non-statutory consultationNoted
  3. East west rail making meaningful connections non-statutory consultationAgreed
  4. A14 cambridge to huntingdon - response to highways agency development consent order pre-application statutory consultationDecided
  5. A14 cambridge to huntingdon - response to highways agency development consent order pre-application statutory consultationDecided
  6. The RSS Review Statutory Consultation ResponseDecided

More from Huntingdonshire Licensing and Protection Panel

All decisions
MeetingDecisionOutcome
23 Jun 2015 Health and safety regulation service plan 2015-16RESOLVED that the 2015/16 Service Plan for Health & Safety Regulation be approved. Approved Open
23 Jun 2015 Representations on external organisationsRESOLVED that nominations be made to the following organisations as indicated in the table below- Organisation Repres... Decided Open
20 May 2015 Election of chairmanRESOLVED that Councillor R Fuller be elected Chairman of the Panel for the ensuing Municipal Year. Councillor R Fulle... Decided Open
20 May 2015 Appointment of vice-chairmanRESOLVED that Councillor L Kadic be appointed Vice-Chairman for the ensuing Municipal Year. Decided Open
24 Mar 2015 Guidelines relating to the relevance and treatment of convictions - hackney carriage and private hire driversRESOLVED that subject to the inclusion of ‘perjury’ and ‘perverting the course of justice’ in ‘Section 44 - the list ... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies