Overview and Scrutiny Panel (Service Support): 2006-09 - transferred to Environmental Well-Being decided this item on Tuesday 8 April 2008. Below is the council's own wording, with the papers it was decided on.
RESOLVED a) that the Chairman be authorised to invite a representative from Anglian Water to attend a future meeting to discuss the way forward; b) that in the event of Anglian Water choosing to accept the invitation, Councillors K Baker, M G Baker and J W Davies be appointed to a working group for the purpose of gathering further information from local residents about the extent and frequency of the problem; c) that details of the recent statutory instrument on compensation for occupiers who had be flooded be provided to all Members; and d) that all Members be informed of the Panel’s investigations and invited to identify any other areas within the District which had experienced similar problems in advance of the discussion with Anglian Water.
Word for word from the decision Huntingdonshire published for this meeting.Source: democracy.huntingdonshire.gov.uk
Report to Overview and Scrutiny Panel (Service Support): 2006-09 - transferred to Environmental Well-Being
OVERVIEW AND SCRUTINY TUESDAY 8TH APRIL 2008 (SERVICE SUPPORT)
SEWERAGE PROBLEMS, ST AUDREY LANE, ST IVES (Report by Chris Allen, Projects and Assets Manager)
1. INTRODUCTION
1.1A petition was presented to the February meeting of the Overview and Scrutiny Panel by residents of the St Audrey Lane area of St Ives, highlighting the problems they experience with their sewerage system during times of storm. At these times, the sewers have overflowed and they loose toilet facilities.
1.2This Council through its Projects and Assets Manager has written to Anglian Water about this matter.
1.3The Committee requested that a further letter be written to Anglian Water and that a report be prepared for this committee explaining the sewerage system and the responsible parties involved in the drainage of this area.
2. RESPONSIBILITIES OF AUTHORITIES
2.1There are several authorities who have responsibilities or powers regarding sewerage systems in the area:
2.2Anglian Water are the Statutory Undertaker for the sewerage system. They own the foul, surface and combined public sewers. The definition of these are: • Foul sewer – pipework taking discharges from internal drainage systems from the houses and industrial units. This is from toilets, sinks, baths, washing machines, etc. • Surface water sewer – pipework taking rainwater from roofs, drives, paths and roads. (See also Highway Drains) • Combined sewer – where there is only one system of pipes in the road, these will often take foul and surface water, and therefore are classed as combined. Recent developments would mostly have separate systems, whereas the older town areas mostly have combined systems. • Pumping Stations – these collect the sewage from catchments and pump it either direct to the sewage works (terminal pumping stations) or into another catchment (in-line pumping stations).
2.3Cambridgeshire County Council Highways are responsible for the adopted roads and pavements, and the associated gulleys. In roads where the pipes only take highway drainage and no flows from properties, then the piped system could be adopted by the County as a Highway Drain.
2.4Huntingdonshire District Council has no ownership of drains in the road. It did own private drains when it owned the Council Houses, but the responsibility went either to new owners or to Luminus when the properties were sold. 2.5 The District Council has power through Environmental Health legislation to serve notice on properties which have defective private or shared drainage to get repairs carried out.
2.6The District Council has permissive powers to carry out repairs to village drains. These are drains which take mainly land drainage, and are usually the old piped ditches laid in highway verges. None of these are known in this area of St Ives. We also have permissive power to get ditches cleaned out if necessary.
2.7The Environment Agency has permissive powers for the maintenance of the main rivers, such as the Gt Ouse and Parsons Drove to the east of St Ives. It would also be the leading authority in checking of pollution of watercourses from discharges from foul sewers into watercourses and taking action.
3. ST AUDREY LANE SEWERAGE SYSTEM
3.1The information given in this section is taken from the information available to the Council and should be taken as indicative of the situation, and not the full detail. To gain the full information would require a full investigation and full access to Anglian Water records.
3.2The town centre of St Ives is mainly on a combined system and drains to a pumping station on Meadow Lane. This pumps the foul flow back into the Pig Lane catchment, with excess storm flows being pumped direct to the river near the lock.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
Follow Overview and Scrutiny Panel (Service Support): 2006-09 - transferred to Environmental Well-Being at Huntingdonshire and we tell you when its next papers are published, before the meeting rather than after it.
Proposals for Riverside Park, HuntingdonRESOLVED that the Panel broadly welcome the scheme but feel that Phase II should be regarded as aspirational only at ...