RESOLVED that: 1. the diffusion tube survey be continued in 2010, to be funded from the Committee’s Discretionary and Environmental Initiatives budget and it be noted that the Committee would like to continue funding this in the next financial year if a budget is available. 2. the New Malden Station monitoring point be relocated to a more central location on the New Malden High Street. Reason for the decision To consider findings from the monitoring of air quality at key locations in New Malden. Knowledge of pollution levels will assist the Committee in decision making in relation to the impact of any future changes in traffic management or development along these roads and inform Council policy when reviewing the Air Quality Action Plan.
Word for word from the decision Kingston upon Thames published for this meeting.Source: moderngov.kingston.gov.uk
The Committee requested that a diffusion tube monitoring survey be undertaken during 2009 to investigate Nitrogen Dioxide levels arising from vehicle emissions along High Street, Malden Road and Burlington Road. Results from the monthly measurements are reported at ANNEX 1 together with annual averages calculated with adjustments in accordance with national guidelines and to reflect for distance reductions. The annual mean measurements for surveys at New Malden Station, Malden Roundabout/Burlington Road Roundabout (The Fountain), Malden Road/ A3 Roundabout and near Burlington Infants and Junior Schools were: 36.83, 51.29, 46.08 and 44.93 respectively. The implication of these measurements on human health is detailed in the report.
Recommendations
It is RECOMMENDED that:
1. the diffusion tube survey be continued in 2010, to be funded from the Committee’s Discretionary and Environmental Initiatives budget.
2. the New Malden Station monitoring point be relocated to a more central location on the New Malden High Street
REASON FOR THE RECOMMENDATIONS To consider findings from the monitoring of air quality at key locations in New Malden.
Background
1. Following a request by the Committee, the Environmental Health Service installed diffusion tubes at 4 roadside locations in New Malden to monitor annual average nitrogen dioxide concentrations against National Air Quality Objective limit values. Three diffusion tubes were located • along the High Street at St Georges Square, • at the Fountain Roundabout adjacent to the former Police Station and • on Malden Road opposite St James Church. In February 2009 an extra tube was located on the Burlington Road adjacent to Burlington Road Primary School.
2. The tubes were exposed for 4/5 week periods for 12 months in accordance with National guidance. Although diffusion tubes are an ideal screening tool, they do not offer the same precision and accuracy of continuous analysers. Monthly results are averaged over the year, when a bias correction is applied to the mean value for validation purposes as it is acknowledged that tube analysis can under/over record N2
levels that would be measured using more accurate but expensive continuous analysers. The bias adjustment can only be applied to the annual average and not to monthly results which vary upon meteorological and other factors. It is important therefore not to make assumptions regarding levels until sufficient data has been collected for outcomes to be statistically significant.
3. There are two limit values for Nitrogen Dioxide: • the 1-hour mean level [200mg/m3 no more than 18x/year] and • the annual mean [40mg/m3].
4. Whilst there is no direct correlation between these levels, recent research does show a statistical relationship which suggests that an annual mean level of not more than 60mg/m3 is unlikely to result in exceedence of the 1-hour mean limit. This fact is of relevance when determining potential “exposure” of the public to harmful concentrations of this pollutant.
FINDINGS
5. The 2009 survey has now been completed and the data adjusted using the recommended bias factor. The results are tabulated in ANNEX 1, together with estimates of the likely reduction in nitrogen dioxide concentration at distance away from roadside. The reductions provide an indication of what concentrations may be at building facades, rather than at the kerb. At 10-20 metres from the roadside monitoring points, all measured levels are expected to fall below the annual mean limit values.
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
Follow Maldens and Coombe Neighbourhood at Kingston upon Thames and we tell you when its next papers are published, before the meeting rather than after it.
Appointment of the Chair and Vice-ChairRESOLVED that Councillor Simon Edwards be appointed Chair and Councillor Lesley Heap be appointed Vice-Chair for the ...