Planning Board, Thursday 9 March 2006

Visits of Inspection

Refused Planning 1 paper

Planning Board refused this item on Thursday 9 March 2006. Below is the council's own wording, with the papers it was decided on.

Item180

Resolved

Resolved :- That permission be refused for the following reason:- The Local Planning Authority considers that the proposed design of the development by reason of its scale and massis out of character in the street scene, detracting from the visual appearance of the area, and would be injurious to the visual amenities of the locality. As such the proposal is considered to be an overdevelopment of the site. This would be contrary to Unitary Development Plan policy ENV3.1 ‘Development and the Environment’. (b) Subdivision of existing shop to form hot food takeaway and erection of rear extension to form store at 66 Blyth Road , Maltby for [name removed] (RB2006/0021) In accordance with the right to speak procedures, the following people attended the meeting and spoke about the application:- [name removed] (Objector) [name removed] (Objector) Councillor B. Slade (Objector) Resolved :- That planning permission be granted, subject to the following conditions:- 1. The materials to be used in the construction of the external surfaces of the development hereby permitted shall match those used in the existing building. 2. Before the development is brought into use the car parking area shown on the approved plan shall be provided, marked out and thereafter maintained for car parking. 3. No part of the land other than that occupied by buildings shall be used for the storage of goods, components, parts, waste materials or equipment without the prior written approval of the Local Planning Authority. 4. All cooking fumes shall be exhausted from the building via a suitable extraction and/or filtration system. This shall include discharges at a point not less than one metre above the highest point of the ridge of the building or any such position as may be agreed in writing by the Local Planning Authority prior to the commencement of the development. The extraction/filtration system shall be maintained and operated in accordance with the manufacturer's specifications, details of which shall be submitted to and approved by the Local Planning Authority prior to installation and it shall thereafter be operated effectively during cooking. All systems shall take into account the document 'Guidance on the Control of Odour and Noise from Commercial Kitchen Exhaust Systems' published by DEFRA January 2005. 5. The use hereby permitted shall not be commenced until ... view the full minutes text for item 180.
Word for word from the decision Rotherham published for this meeting. Source: moderngov.rotherham.gov.uk

Follow this further

Built from Rotherham's papers

What the report saysPro

Report to Planning Board
This report is being read into text

Papers are read newest first, so recent reports come through within hours. Until then, open it at source.

Open the PDF

Papers for this item

Kept in our archive, download once signed in
PDF
Visits of InspectionReport 451 KB Download

At this meeting

Whole meeting

Who was there

16 of 21 attended
SW
Councillor Sheila WalkerChair, present
AA
Councillor Alan AtkinMember, present
PB
Councillor Patrick BurkeMember, apologies
JB
Councillor Josephine BurtonMember, absent
BC
Councillor Brian CuttsMember, apologies
BD
Councillor Barry DodsonMember, present
DH
Councillor David HallMember, present
BK
Councillor Barry KayeMember, present
NL
Councillor Neil LicenseMember, present
RL
Councillor Reg LittleboyMember, apologies
RM
Councillor Rose McNeelyMember, present
GN
Councillor Geb NightingaleMember, present

All 21 on the meeting page

On this subject at Rotherham

Search all
  1. Visits of InspectionThis decision
  2. Visits of InspectionApproved
  3. Introduction of a charging scheme for Food Hygiene Rating re-inspection visitsDecided
  4. Introduction of a charging scheme for Food Hygiene Rating re-inspection visitsDecided
  5. Visits of Inspection - Erection of a building for use as soft play area (use class D2) and ancillary café and toilets at Aston Springs Farm, Aston for Mr Swain (RB2015/0237)Refused
  6. Visits of Inspection - Increase in roof height to form two storey dwelling house including single storey rear extension and flue to side (amendment to RB2014/0809) at 20 Manor Way, Todwick for Mr. S. Wilkinson (RB2014/1296)Agreed

More from Rotherham Planning Board

All decisions
MeetingDecisionOutcome
29 Oct 2026 Minutes of the previous meeting held on 8th October 2026- That the minutes of the previous meeting of the Planning Regulatory Board held on Thursday, 8 th October, 2026, be ... Approved Open
29 Oct 2026 Development Proposals- (1 ) That , on the development proposals now considered, the requisite notices be issued and be made available on t... Approved Open
29 Oct 2026 Report of the Service Director for Planning, Regeneration and Transport - Whitestone Solar Farm - Nationally Significant Infrastructure Project Update- That the update be received and the contents noted. Noted Open
8 Oct 2026 Minutes of the previous meeting held on 17th September, 2026- That the minutes of the previous meeting of the Planning Regulatory Board held on Thursday, 17 th September, 2026, ... Approved Open
8 Oct 2026 Development Proposals- (1) That, on the development proposals now considered, the requisite notices be issued and be made available on the... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies