CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
Rotherham Metropolitan Borough Council
Planning Board, Thursday 3 July 2008

Visits of Inspection

Approved Planning 1 paper

Planning Board approved this item on Thursday 3 July 2008. Below is the council's own wording, with the papers it was decided on.

Item33

Resolved

Resolved :- That planning permission be granted for the reasons adopted by Members at the meeting and appended to the minutes and subject to the following conditions:- 1. The permission, hereby granted, shall relate to the area shown outlined in red on the approved site plan and the development shall only take place in accordance with the submitted details and specifications as shown on the approved plans (as set out below) and written statement dated February, 2008 except as shall be otherwise agreed in writing by the Local Planning Authority (Drawing CS/0522/2 received on 8th February, 2008). 2. Except in case of emergency, no operations shall take place on site other than between the hours of 0800 to 1800 hours Monday to Friday and between 0800 to 1300 hours on Saturdays. There shall be no working on Sundays or Public Holidays. At times when operations are not permitted work shall be limited to maintenance and servicing of plant or other work of an essential or emergency nature. The Local Planning Authority shall be notified at the earliest opportunity of the occurrence of any such emergency and a schedule of essential work shall be provided. 3. Prior to being discharged into any watercourse, surface water sewer or soakaway system, all surface water drainage from parking areas and hardstandings shall be passed through an oil interceptor designed and constructed to have a capacity and details compatible with the site being drained. Roof water shall not pass through the interceptor. 4. Any facilities for the storage of oils, fuels or chemicals shall be sited on impervious bases and surrounded by impervious bund walls. The volume of the bunded compound should be at least equivalent to the capacity of the tank plus 10%. If there is multiple tankage , the compound should be at least equivalent to the capacity of the largest tank, or the combined capacity of interconnected tanks, plus 10%. All filling points, vents, gauges and sight glasses must be located within the bund. The drainage system of the bund shall be sealed with no discharge to any watercourse, land or underground strata. Associated pipework should be located above ground and protected from accidental damage. All filling points and tank overflow pipe outlets should be detailed to discharge downwards into the bund. 5. All metal recycling materials shall be stored within the proposed bays in the processing area on site as shown in the approved plan. 6. Details of the proposed concrete ... view the full minutes text for item 33.
Word for word from the decision Rotherham published for this meeting. Source: moderngov.rotherham.gov.uk

Follow this further

Built from Rotherham's papers

What the report saysPro

Report to Planning Board
This report is being read into text

Papers are read newest first, so recent reports come through within hours. Until then, open it at source.

Open the PDF

Papers for this item

Kept in our archive, download once signed in
PDF
Visits of InspectionReport 586 KB Download

At this meeting

Whole meeting

Who was there

17 of 21 attended
DP
Councillor Dave PickeringChairman, present
AR
Councillor Ann RussellMember, apologies
JA
Councillor Jahangir AkhtarMember, present
SA
Councillor Shaukat AliMember, present
AA
Councillor Alan AtkinMember, present
JA
Councillor Jane AustenMember, present
BB
Councillor Beryl BillingtonMember, present
JB
Councillor Josephine BurtonMember, apologies
BD
Councillor Barry DodsonMember, present
BK
Councillor Barry KayeMember, present
NL
Councillor Neil LicenseMember, present
RL
Councillor Reg LittleboyMember, apologies

All 21 on the meeting page

On this subject at Rotherham

Search all
  1. Visits of InspectionThis decision
  2. Visits of InspectionApproved
  3. Introduction of a charging scheme for Food Hygiene Rating re-inspection visitsDecided
  4. Introduction of a charging scheme for Food Hygiene Rating re-inspection visitsDecided
  5. Visits of Inspection - Erection of a building for use as soft play area (use class D2) and ancillary café and toilets at Aston Springs Farm, Aston for Mr Swain (RB2015/0237)Refused
  6. Visits of Inspection - Increase in roof height to form two storey dwelling house including single storey rear extension and flue to side (amendment to RB2014/0809) at 20 Manor Way, Todwick for Mr. S. Wilkinson (RB2014/1296)Agreed

More from Rotherham Planning Board

All decisions
MeetingDecisionOutcome
29 Oct 2026 Minutes of the previous meeting held on 8th October 2026- That the minutes of the previous meeting of the Planning Regulatory Board held on Thursday, 8 th October, 2026, be ... Approved Open
29 Oct 2026 Development Proposals- (1 ) That , on the development proposals now considered, the requisite notices be issued and be made available on t... Approved Open
29 Oct 2026 Report of the Service Director for Planning, Regeneration and Transport - Whitestone Solar Farm - Nationally Significant Infrastructure Project Update- That the update be received and the contents noted. Noted Open
8 Oct 2026 Minutes of the previous meeting held on 17th September, 2026- That the minutes of the previous meeting of the Planning Regulatory Board held on Thursday, 17 th September, 2026, ... Approved Open
8 Oct 2026 Development Proposals- (1) That, on the development proposals now considered, the requisite notices be issued and be made available on the... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies