P15/S2946/FUL - Goring-on-Thames weir

Approved Planning 2 papers

Planning Committee approved this item on Wednesday 9 March 2016. Below is the council's own wording, with the papers it was decided on.

Item131

Resolved

to grant planning permission for application P15/S2946/FUL, subject to the following conditions: 1. Work to commence within three years. 2. In accordance with approved plans. 3. Flood risk mitigation – in accordance with flood risk assessment. 4. Construction traffic management plan. 5. Schedule of materials, finishes and detailing. 6. Specification of the archimedes screw. 7. Fish pass design and details. 8. Eel pass design and details. 9. Acoustic assessment. 10. Wildlife protection. 11. No lighting. Informatives 1. Wild bird and nest protection. 2. Public right of way – liaison with Oxfordshire County Council. 3. Flood defence consent.
Word for word from the decision South Oxfordshire published for this meeting. Source: democratic.southoxon.gov.uk

Follow this further

Built from South Oxfordshire's papers

What the report saysPro

Report to Planning Committee

Agenda Item 8 Appendix 1 Page 37 PL2/001/2 PLA/001

NOTES 1. BOUNDARY OF PERMANENT WORKS OUTLINED IN RED. TEMPORARY WORKS INCLUDING COFFER DAM WILL OCCUPY A SLIGHTLY LARGER AREA.

2. WORKS INCLUDE THE REMOVAL OF THE EXISTING OVERFALL WEIR AND FISH PASS ADJACENT TO THE LOCK ISLAND, AND THE CONSTRUCTION OF A NEW CONTROL HUT FLOOD CONTROL GATE, THREE ARCHIMEDES SCREWS, THEIR SUPPORTING CONCRETE STRUCTURES, AND A NEW LARINIER FISH PASS, A CONTROL BUILDING, A NEW EEL PASS ON GORING WEIR AND MODIFICATIONS TO THE CREST ANGLES ON GORING AND STREATLEY WEIRS. POWER CABLES FIXED TO NEW STRUCTURE AND TO 3. EXACT ROUTE OF UNDERGROUND CABLES FROM EXISTING BRIDGE AND THEN HYDRO PLANT, FISH PASS END OF EXISTING BRIDGE TO CONNECTION TO THE BURIED IN RIVER BED AND ON AND NEW FLOOD GRID TO BE AGREED WITH ENVIRONMENT AGENCY SHORE TO GRID CONNECTION POINT CONTROL GATE IN RIVER AND WITH SWAN HOTEL WITHIN THEIR (EXACT ROUTE YET TO PROPERTY BOUNDARY. BE DETERMINED)

GORING 4. FINISHES ON EXISTING WORKS TO MATCH EXISITING - WEIR STEEL WORK TO BE PAINTED GREY TO MATCH ENVIRONMENT AGENCY'S GATES ETC; STRUCTURE IN EEL PASS FIXED RIVER TO BE PARTAILLY FACED IN BRICK TO MATCH TO SURFACE OF WEIR EXISTING; CHANNELS FOR ARCHIMEDES SCREWS TO BE BARE CONCRETE AS LOCK AND LOCK APPROACHES. LENGTH OF STEEL CREST ANGLE 5. DETAILED DESIGN OF WORKS INCLUDING FISH PASS TO BE RAISED TO BE SUBJECT TO INDEPENDENT REVIEW AND BY 50mm APPROVAL BY ENVIRONMENT AGENCY.

Appendix 2

2 1/16 FOR MODIFIED PLANNNG APPLICATION 1 7/15 FOR PLANNIG APPROVAL

LENGTH OF STEEL CREST ANGLE TO BE LOWERED BY 50mm

Goring and Streatley Community Energy Ltd STREATLEY WEIR Goring & Streatley Hydro Project

SITE PLAN

0 50 Page 38

Scale 1:1000

PL2/001 2 PL2/002/1

NOTES

1. THE ELEVATIONS SHOWN ARE DEVELOPED ALONG THE CURVED LINE OF THE WEIR STRUCTURE

NORMAL DOWNSTREAM WATER LEVEL

EXISTING DEVELOPED DOWNSTREAM ELEVATION

1 7/15 FOR PLANNING APPLICATION

EXISTING UPSTREAM DEVELOPED ELEVATION

Goring and Streatley Community Energy Ltd

Goring & Streatley Hydro Project

EXISTING DEVELOPED ELEVATIONS

0 10 Page 39

Scale 1:250

PL2/002 1 PL2/004/2 NOTES

1 THE ELEVATIONS SHOWN ARE DEVELOPED ALONG THE CURVED LINE OF THE WEIR STRUCTURE.

ACOUSTIC HOOD 45.80m AOD - TOP OF MAINTENANCE HOIST 45.05m AOD - TOP OF ACOUSTIC ENCLOSURES

2 1/16 FOR MODIFIED PLANNING APLICATION 1 7/15 FOR PLANNING APPLICATION NEW LARINIER 3 No. ARCHIMEDES SCREWS NEW 3m WIDE EXISTING 4m WIDE EXISTING OVERFALL WEIR FISH PASS EACH 3.5m DIAMETER FLOOD CONTROL GATE FLOOD CONTROL GATES

PROPOSED UPSTREAM ELEVATION Goring and Streatley Community Energy Ltd

Goring & Streatley Hydro Project

PROPOSED DEVELOPED ELEVATIONS

0 10 Page 40

Scale 1:250

PL2/004 2 PL2/016/1 NOTES

CONTROL HUT CONCRETE WALLS 250 THICK 1. CONTROL HUT TO BE A WATERTIGHT WATERTIGHT DOOR 900 WIDE CONCRETE BUILDING TO PROVIDE FLOOD RESILIENCE TO ELECTRICAL EQUIPMENT INSIDE. STEEL DOOR TO BE WATERTIGHT. WALLS TO BE PAINTED WHITE, DOOR AND ANY TIMBER TO BE PAINTED BLACK WITH PLAN CLAY TILES TO PITCHED ROOF, ALL TO MATCH EXISTING LOCK-KEEPER'S HOUSE. CABLE ENTRIES TO BUILDING TO BE ABOVE VENTILATION GRILLE 100 YEAR FLOOD LEVEL

4500 3500

EAST ELEVATION NORTH ELEVATION

VENTILATION GRILLE

CONTAINMENT FOR CABLE AND HYDRAULIC LINES. ENTRY TO BUILDING ABOVE FLOOD LEVEL. WATERTIGHT DOOR 1 1/16 FOR MODIFIED ;PLANNING APPLICATION CONTAINMENT TO CONNECT TO STRUCTURE IN RIVER VIA ACCESS WALKWAY ACROSS FISH PASS.

.

WEST ELEVATION SOUTH ELEVATION Goring & Streatley Hydro Project

MISCELLANEOUS DETAILS CONTROL HUT ON ISLAND 0 5

Scale 1:100 Page 41

PL2/016 1 Page 42 Photos referenced from Visual Impact Assessment - section 3 of the Environmental Report (Rogers 2009)

View across to weir from Lock footpath - Site visit photo

Page 43 This page is intentionally left blank

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
P15/S2946/FUL: Goring-on-Thames weir: AppendicesReport 12 MB DownloadRead as text
PDF
P15/S2946/FUL: Goring-on-Thames weirReport 191 KB Download

At this meeting

Whole meeting

Who was there

15 of 15 attended
NM
Nicola MeurerOfficer, present
JB
Joan BlandCommittee Member, present
FB
Felix BloomfieldChairman, present
MD
Margaret DaviesCommittee Member, present
AD
Anthony DearloveCommittee Member, present
JM
Jeannette MatelotCommittee Member, present
LH
Lorraine HillierCommittee Member, apologies, sent representative
TN
Toby NewmanCommittee Member, present
RP
Richard PullenCommittee Member, present
DT
David TurnerCommittee Member, present
MT
Margaret TurnerCommittee Member, present
DN
David Nimmo-SmithSubstitute, present as substitute

All 15 on the meeting page

On this subject at South Oxfordshire

Search all
  1. P15/S2946/FUL - Goring-on-Thames weirThis decision
  2. P25/S0357/FUL - 1 Enigma Estate, Coldharbour, Goring Heath, RG8 7SZApproved
  3. P22/S0924/FUL - Ridgeway Rise, Goring, RG8 0JYApproved
  4. P22/S1992/FUL - 2 Elvendon Road, Goring, RG8 0DUApproved
  5. P22/S0788/FUL - Stow House Thames Road, Goring, RG8 9ALApproved
  6. P20/S2373/FUL - Former Lloyds Bank, High Street, Goring, RG8 9ATApproved

More from South Oxfordshire Planning Committee

All decisions
MeetingDecisionOutcome
12 Aug 2026 Minutes of the previous meetingRESOLVED : to approve the minutes of the meeting held on 30 August 2026 as a correct record and agree that the Chair ... Approved Open
12 Aug 2026 P25/S0350/FUL - Land to the rear of Pennyhill Woodlands Road Harpsden, RG9 4AAto delegate to the Director of Planning, in consultation with the Chair of Planning Committee, to grant planning perm... Decided Open
12 Aug 2026 P25/S3304/FUL - Land to the rear of 87-89 Lower Icknield Way, Chinnor, OX39 4EAto approve planning application P25/S3304/FUL subject to the following conditions: Commencement 3 years – Full Planni... Approved Open
30 Jul 2026 Minutes of the previous meetingRESOLVED : to approve the minutes of the meeting held on 15 July 2026 as a correct record and agree that the Chair si... Approved Open
30 Jul 2026 P25/S3380/FUL - Breach Farm, Wheatley Road, Stanton St John, OX33 1FGto approve planning application P25/S3380/FUL subject to the following conditions: Commencement 3 years – Full Planni... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies