CouncilMonitor
194 principal councils 228,996 meetings since 2000 2.8 million official papers archived Straight from each council's own publication system
South Oxfordshire District Council
Planning Committee, Wednesday 28 September 2016 at 6.00pm

P16/S0806/FUL - The Wychens, 70 Queen's Road, Thame

Refused Planning 2 papers

Planning Committee refused this item on Wednesday 28 September 2016. Below is the council's own wording, with the papers it was decided on.

Item93

Resolved

RESOLVED To refuse the application for planning permission for the following reasons: · Significant loss of amenity to the immediate neighbour, created by the increase in height so close to the boundary. · Unneighbourliness .
Word for word from the decision South Oxfordshire published for this meeting. Source: democratic.southoxon.gov.uk

Follow this further

Built from South Oxfordshire's papers

What the report saysPro

Report to Planning Committee

Agenda Item 10 Appendix 1

Page 77 10000E

10025E

10050E

10075E NOTES GENERAL NOTES :- ALL LEVELS ARE IN METRES RELATED TO AN ASSUMED DATUM LOCATED ON INSPECTION COVER 5025N 5025N AS SHOWN. (value 100.00m).

THE COORDINATE GRID IS BASED ON ASSUMED VALUES.

THIS DRAWING HAS BEEN PRODUCED WITH A PLOT SCALE ACCURACY OF 1:100

SERVICE COVERS INDICATED WHERE VISIBLE. PIPE INVERTS / DETAILS SURVEYED FROM SURFACE INSPECTION ONLY. GENERALLY DAMAGED COVERS AND COVERS WITHIN HIGHWAYS WILL NOT BE LIFTED

TREE SPECIES SHOULD BE CONFIRMED BY TREE SPECIALIST IF CRITICAL.

OVERHEAD CABLES ARE INDICATED USING REMOTE SURVEY METHODS AND ARE SUBJECT TO SEASONAL VARIATION, AND SHOULD BE TREATED AS APPROXIMATE.

SERVICE COVERS LOCATED UNDER PARKED VEHICLES/MOBILE STRUCTURES MAYBE OMITTED. BURIED SERVICE COVERS WILL NOT BE INDICATED.

TOPOGRAPHICAL SURVEY/UTILITY KEY :-

(ht) - height mkr - marker ∅ - diameter o/h - over head - pea trap ol - off let a/g - above ground osa - off survey area a/r - assumed route OSBM - ordnance survey bench mark av - air valve p & r fence - post & rail fence bb - belisha beacon pd - pit depth bd - back drop ptg - pipe to ground boll - bollard re - rodding eye bos - bottom of shaft ret wall - retaining wall bt - telecom rs - road sign rwp - rain water pipe

Appendix 2 c/b fence - closeboard fence c/box - control box s/birch - silver birch catv - cable television s/p - safety paving cl - cover level sap - sapling con - conifer sec fence - security fence cr - cable riser sfc - soil filled chamber cwc - combined water sewer sl - spot light d/chan - drainage channel sp - soil pipe dp - depth st - stop tap 99.82 ejb - electric junction box sv - stop valve elec - electric svp - soil vent pipe eot - end of trace sws - storm water sewer ep - electric pole TBM - temporary bench mark er - earth rod tfr - taken from records 99.92 f/bed - flower bed tl - threshold level fh - fire hydrant toc - top of cap fl - floor level top - top of pipe fs - fire switch tot - top of tank fwc - foul water chamber tp - telecom pole 99.96 fws - foul water sewer ts - traffic signal g - gully t/s - to surface g/run - gully run u/s - underside ) gr - gas riser utl - unable to lift 70 0. h/chestnut - horse chestnut utr - unable to rod (ht h/thorn - hawthorn uts - unable to survey ll utt - unable to trace ic - inspection cover wa il - invert level vp - vent pipe ick ill - illuminated wfc - water filled chamber br int - interceptor wl - water level wm - water meter lp - lamp post wp - waste pipe mh - manhole cover wr - water riser 99.82 99.97

g 99.93 private property tp SURVEY CONTROL :- 99.65 STATION EASTINGS NORTHINGS LEVEL 99.79 99.92 ST01 10000.000 5000.000 99.529

D INDICATIVE

A O 100.04 ST02 10030.018 4984.705 99.899

R NORTH ST03 10039.917 4986.907 99.850 S N E E

100.02 U

s as Q

gr brick building 99.93 ridge level 105.77 eaves level 102.32 99.55 100.16 99.80 99.94 99.67 rwp 100.16 wire fen ce (ht UTILITY SURVEY KEY :- 1.2 )

0) ELECTRIC CABLE 80 1.

WATER PIPE t

FOUL SEWER (h

STORM SEWER e

99.47dg

5000N ST01 5000N 99.88 HATCHED AREA he

Read every report as text, not just the decision

Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.

Papers for this item

Kept in our archive, download once signed in
PDF
P16/S0806/FUL: The Wychens, 70 Queen's Road, Thame: AppendicesReport 1.6 MB DownloadRead as text
PDF
P16/S0806/FUL: The Wychens, 70 Queen's Road, ThameReport 117 KB Download

At this meeting

Whole meeting

Who was there

14 of 16 attended
JB
Joan BlandCommittee Member, apologies, sent representative
FB
Felix BloomfieldChairman, present
MD
Margaret DaviesCommittee Member, present
AD
Anthony DearloveCommittee Member, present
JM
Jeannette MatelotCommittee Member, present
TN
Toby NewmanCommittee Member, present
DN
David Nimmo-SmithCommittee Member, present
RP
Richard PullenCommittee Member, present
DT
David TurnerCommittee Member, present
MT
Margaret TurnerCommittee Member, apologies, sent representative
IW
Ian WhiteCommittee Member, apologies, sent representative
SH
Stephen HarrodSubstitute, present

All 16 on the meeting page

On this subject at South Oxfordshire

Search all
  1. P16/S0806/FUL - The Wychens, 70 Queen's Road, ThameThis decision
  2. P17/S1018/FUL - The Wychens, 70 Queen's Road, ThameApproved

More from South Oxfordshire Planning Committee

All decisions
MeetingDecisionOutcome
12 Aug 2026 Minutes of the previous meetingRESOLVED : to approve the minutes of the meeting held on 30 August 2026 as a correct record and agree that the Chair ... Approved Open
12 Aug 2026 P25/S0350/FUL - Land to the rear of Pennyhill Woodlands Road Harpsden, RG9 4AAto delegate to the Director of Planning, in consultation with the Chair of Planning Committee, to grant planning perm... Decided Open
12 Aug 2026 P25/S3304/FUL - Land to the rear of 87-89 Lower Icknield Way, Chinnor, OX39 4EAto approve planning application P25/S3304/FUL subject to the following conditions: Commencement 3 years – Full Planni... Approved Open
30 Jul 2026 Minutes of the previous meetingRESOLVED : to approve the minutes of the meeting held on 15 July 2026 as a correct record and agree that the Chair si... Approved Open
30 Jul 2026 P25/S3380/FUL - Breach Farm, Wheatley Road, Stanton St John, OX33 1FGto approve planning application P25/S3380/FUL subject to the following conditions: Commencement 3 years – Full Planni... Approved Open

We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies