What was decided
Full planning permission was granted for 2 floodlit 3G pitches, 5 grass football pitches, a clubhouse and pavilion with changing and football academy facilities, padel tennis courts, a play zone, car parking, landscaping, boundary treatment and access. Report P1, P2
Condition 25 was amended to require a minimum of 40 cycle parking spaces to meet Transport for London objectives and promote sustainable travel. Report P74, P75, P76, P77, P78
Condition 38 was amended to require the Active Travel Zone Assessment to investigate a second pedestrian access to the south of the site near the bus stop, and Condition 39 was amended to require permeable paving, landscaping and substantial canopy cover to increase Biodiversity Net Gain. Report P123, P124, P125, P126, P127
An informative was added requiring the applicant or operator to set up a residents' liaison group to monitor any impact of lighting and noise from the padel courts.
Why
The application was recommended for approval subject to the conditions in Appendix 2, with the amendments made at the meeting to address cycle parking, pedestrian connectivity, biodiversity, and community concerns about lighting and noise. Report P4, P78, P125, P129
Officers considered the proposal acceptable in planning terms, subject to safeguards covering construction impacts, archaeology, contamination, drainage, energy, ecology, inclusive design, sport facility standards and amenity protection for neighbours. Report P12, P17, P20, P26, P50, P67, P99, P109, P120
What happens next
Before construction starts, the developer must submit and gain approval for a Construction Logistics Plan, Construction Management Plan, a written scheme of investigation for archaeology, a contamination remediation strategy, a UXO risk assessment, drainage and flood attenuation details, a Biodiversity Gain Plan, a Habitat Management and Monitoring Plan, an Ecological Compensation and Enhancement Plan, a Construction Environmental Management Plan, and an updated BNG metric with proof of any off-site unit purchase. Report P12, P17, P20, P26, P27, P79, P83, P89, P140, P144, P156
Before the new pavilion is occupied, the temporary structure on site must be removed, a community use agreement must be approved in consultation with Sport England, and an Operations Management Plan covering hours, events, parking, CCTV and lighting must be in place. Report P106, P113, P135
Within 6 months of completing the clubhouse, a BREEAM post-construction assessment confirming the Excellent rating must be submitted, and the artificial grass pitches must be certified to FIFA Quality or equivalent and registered with the Football Association. Report P43, P109
Options considered
- Chosen: Grant full planning permission subject to conditions and amendments. Recommended by officers, with meeting amendments to address cycling, pedestrian access, biodiversity and resident liaison on lighting and noise Report P4
Implications
- Climate: The clubhouse must achieve a BREEAM Excellent rating, the energy and sustainability measures in the approved Energy and Sustainability Statement must be implemented, and a biodiverse green roof is required on the clubhouse. Report P43, P44, P46, P48, P130
- Legal: The decision is subject to conditions covering contamination, unexploded ordnance, archaeology, tree protection, hours of operation, and a community use agreement with Sport England for the 3G pitches and padel courts. Report P20, P26, P17, P132, P99, P113
- Equalities: Inclusive design measures must comply with Building Regulations Approved Document M Volume 2, including accessible routes, lifts, unisex WCs, showers and changing rooms, and access to disabled parking, with details agreed with the Council's Housing Occupational Therapist. Report P67, P68, P69, P70
- Other: Construction noise, vibration and air quality controls apply, including NRMM emission standards registered with the London NRMM register, floodlighting must be switched off by 9.30pm, and padel court hours are limited to 8am to 9.30pm Monday to Saturday and 8am to 8pm on Sundays and bank holidays. Report P30, P31, P32, P99, P118, P119, P120, P121
- Risk: Biodiversity Net Gain must be at least 10%, with a 30-year Habitat Management and Monitoring Plan, off-site credits where required, and replacement of a veteran oak tree at a 10:1 ratio alongside veteranising existing mature trees on the boundary. Report P87, P88, P89, P92, P98, P149, P156
Who and where
- Residents of Eltham Town and Avery Hill ward, including near Footscray Road Report P162
- Future users of the football academy, grass pitches, 3G pitches, padel courts and play zone Report P1, P2
- Transport for London and local highway users on Footscray Road Report P12, P57, P137
- Thames Water and the Lead Local Flood Authority for drainage matters Report P79
- Sport England as consultees on the community use agreement and facility standards Report P109, P111, P113, P115
Timeline
- Within three years of the date permission is granted: Development must be begun Report P5, P6
- Prior to commencement: Construction Logistics Plan, Construction Management Plan, archaeology WSI, contamination remediation strategy, UXO risk assessment, drainage details, Biodiversity Gain Plan, HMMP, CEMP, ecological compensation plan, tree protection details and BNG metric must be submitted and approved Report P12, P17, P20, P27, P79, P83, P89, P132, P140, P144, P156
- Within three months of the new pavilion being occupied: Temporary structure on the site must be removed in full Report P135
- Within 6 months of completing the clubhouse: BREEAM post-construction assessment confirming Excellent rating to be submitted Report P43
- Within two months of completing the approved remediation works: Contaminated land verification report to be submitted and approved Report P23
- For 30 years from completion of the development: Habitat Management and Monitoring Plan to be maintained Report P92, P98
Plain English for the jargon
- 3G pitch: Third generation artificial grass pitch used for football
- BNG: Biodiversity Net Gain, the measurable improvement in biodiversity for a site after development
- BREEAM: Building Research Establishment Environmental Assessment Method, a sustainability rating for buildings
- HMMP: Habitat Management and Monitoring Plan required to deliver Biodiversity Net Gain over the long term
- NRMM: Non-Road Mobile Machinery, construction plant and equipment that must meet emission standards
- TfL: Transport for London, the strategic transport authority for London
- UXO: Unexploded Ordnance, requiring risk assessment before construction on sites with potential wartime bombing