Maldens and Coombe Neighbourhood decided this item on Wednesday 16 January 2008. Below is the council's own wording, with the papers it was decided on.
RESOLVED that 3 sites for the location of diffusion tubes be identified in the vicinity of New Malden High Street and monitoring be carried out for one year (as described in paragraph 5 ii of the report). The method of monitoring and results shall be shared with local schools to encourage community involvement in the investigation. Funding of £150 to be provided from the Neighbourhood’s Discretionary and Environmental Initiatives budget for this initiative. Reason for the decision In order to monitor the air quality in New Malden High Street.
Word for word from the decision Kingston upon Thames published for this meeting.Source: moderngov.kingston.gov.uk
At its meeting on 10 October, the Committee requested a report on emissions testing on New Malden High Street and eventually on the stretch of road between the Fountain roundabout and the A3. This report outlines options for monitoring air quality in New Malden High Street and possibly on a wider basis within the Neighbourhood.
Recommendation
It is RECOMMENDED that the Committee consider the options for monitoring air quality in New Malden High Street (as set out in para. 5 of the report) in relation to the financial implications (ref. para. 6 of the report).
Reason for recommendation
In order to consider how the air quality in New Malden High Street could be monitored.
Background
1. As a part of its Local Air Quality Management (LAQM) responsibilities, the Council completed a review and assessment (R&A) of air quality between 1999 and 2003. This review looked at the seven air pollutants in the Government’s air quality strategy i.e. nitrogen dioxide (NO2), particulates (PM10), benzene, 1,3 butadiene, carbon monoxide, lead and sulphur dioxide (S0 2).
2. Of these, only nitrogen dioxide and particulates were found to potentially exceed the air quality objectives at kerb side on parts of the A3, A308, A240, A2043, A307, A238 and A243. New Malden High Street was not a location where exceedences are predicted and this has been confirmed by more recent assessments using updated data.
METHODOLOGY OF ASSESSMENT FOR LAQM
3. As with all local authorities, review and assessment of air quality has been undertaken (in our case, by consultants) using computer modelling that takes account of factors such as traffic flow, vehicle types, weather, improvements in vehicle technology and other emissions contributors. This is validated by using data from monitoring stations across London including the DEFRA operated station at Tolworth on the A3. It is not based on actual current air pollution levels as measured. I2
HIGH STREET NEW MALDEN
4. As indicated earlier, the review and assessment has not identified New Malden High Street as a location where the annual average N02 and PM10 air quality objectives are or will be exceeded.
5. However, if the Committee wishes actually to measure levels of NO2, the following alternatives are open to it:
i) Provide a temporary portable monitoring station to investigate both N02 and PM10 over an acceptable period [say 4 months] so as to give an averaged reading that can be compared with guidelines. Depending upon the detail and length of the study, this is likely to cost up to £10,000. The location of the cabin and provision of power supply may be problematic, as can be the choice of monitoring period and security.
ii) Carry out an investigation of annual average NO2 levels using diffusion tubes located on street furniture. It must be noted that particulates (PM10) cannot be measured using diffusion tubes. Each diffusion tube is exposed for 4 week periods when they are replaced and sent for analysis. This should be undertaken for at least a year and report in order to allow comparison with the air quality objective. The cost per location for diffusion tubes (including analysis and report) is approximately £50 per annum excluding staff costs for placement, postage and administration.
iii) As a further option the Committee may wish to consider involving local community groups or schools in a wider survey of possibly 5 or 6 areas where pollution may be of local concern, Again the cost per location would be around £50 per site and local groups or organizations may wish to carry out the administration and replacement of the tubes, thereby enhancing community involvement and saving on costs. Community monitoring has been successfully implemented by other local authorities and, if so requested, a further report can be brought to the Committee following consultation and a feasibility exercise involving local groups and schools.
Financial implications
Read every report as text, not just the decision
Pro opens the officer report behind each decision, searchable and quotable, across every council we cover.
Follow Maldens and Coombe Neighbourhood at Kingston upon Thames and we tell you when its next papers are published, before the meeting rather than after it.
Appointment of the Chair and Vice-ChairRESOLVED that Councillor Simon Edwards be appointed Chair and Councillor Lesley Heap be appointed Vice-Chair for the ...