Fulham Gas Works, Imperial Road London, Parsons Green and Sandford, 2025/00568/LBC
DecidedPlanning1 paper
AI summaryHammersmith and Fulham committee authorises the Director of Planning and Property to grant listed building consent for restoration and reconfiguration works to the Grade II* Gasholder No. 2 at Fulham Gas Works, subject to conditions.
Written from the decision and the officer reportPDF Pro
OutcomeDecidedSubject to conditions and Secretary of State direction
MoneyNot stated
What happens nextDirector to grant consentAfter no contrary direction from Secretary of State
Who it affectsFulham Gas Works, Imperial RoadGasholder No. 2 in Conservation Area Number 6
What was decided
The committee authorised the Director of Planning and Property, after consultation with the Assistant Director of Legal Services and the Chair of the committee, to determine the application, grant listed building consent and make any changes to the conditions. Report P11, P12
Conditions cover a three year time limit, compliance with approved drawings, paint analysis before removal, and submission of material samples before erection. Report P14, P17, P25, P27
Why
Officers found the Grade II* Gasholder No. 2 is in very poor condition, its original use is redundant, and the proposals are the best available way to conserve its significance by salvaging and reinterpreting parts of the structure. Report P31
Officers considered the substantial harm from loss of the original form, and less than substantial harm to the settings of adjacent listed buildings, would be outweighed by the heritage, public realm and conservation benefits, including creation of a centrepiece for the public space within the wider development site. Report P31, P32
The works were judged acceptable under Section 16 of the Planning (Listed Buildings and Conservation Areas) Act 1990, the National Planning Policy Framework, London Plan 2021 policies D3, D4, D5, D8 and HC1, and Local Plan 2018 policies DC1, DC2 and DC8. Report P33
What happens next
The Director of Planning and Property will determine the application and grant listed building consent once any direction from the Secretary of State is confirmed. Report P11
Before any paint is removed, an appropriately qualified party must analyse the existing paint finish, with details submitted to and approved in writing by the Local Planning Authority in consultation with Historic England. Report P25
Before erection, details of external materials including physical samples for replacement elements, masonry bases, infill panels and anti-bird fouling measures must be submitted to and approved by the Local Planning Authority in consultation with Historic England. Report P27
Options considered
Chosen: Grant listed building consent subject to conditions, as recommended by officers. Officers judged heritage and public benefits outweigh the harm from loss of the original gasholder form Report P10, P11, P31, P33
Rejected: Refuse listed building consent Report P31, P33
Implications
Other: Gasholder No. 2 will be recorded, dismantled in part, refurbished off site, and re-erected in a new configuration with salvaged and replacement components, integrated into the wider landscaped park with a water feature and seating. Report P7, P31
Legal: Listed building consent is granted under the Planning (Listed Buildings and Conservation Areas) Act 1990, with the three year commencement time limit required by Section 18(1)(a). Report P14, P15
Other: The works must be carried out in accordance with the listed approved drawings and supporting documents including the Design and Access Statement, Craddys refurbishment technical requirements, Alloy Fabweld detailed methodology, and Montagu Evans heritage statement. Report P17, P18, P19, P20, P21, P22, P23, P24
Risk: Decision remains subject to any contrary direction from the Secretary of State. Report P11
Who and where
Owners and future users of Fulham Gas Works, Imperial Road Report P2, P5
Adjacent listed buildings, including the Grade II Office building, Grade II Laboratory building and Grade II WW1 war memorial, whose settings were considered Report P32
Historic England, consulted on paint analysis and external materials Report P25, P27, P39
Greater London Industrial Archaeology Society, which submitted consultation comments Report P39
Hammersmith and Fulham Historic Buildings Group, which submitted consultation comments Report P39
Timeline
28 February 2025: Application form received Report P36
14.04.2025: Comments received from Historic England Report P39
15.04.2025: Comments received from Hammersmith and Fulham Historic Buildings Group Report P39
16.04.2025: Comments received from Greater London Industrial Archaeology Society Report P39
12.01.2026: Further comments received from Historic England Report P39
20.01.2026: Planning and Development Control Committee considered the application Report P4
Plain English for the jargon
Listed Building Consent: Permission required under the Planning (Listed Buildings and Conservation Areas) Act 1990 to carry out works that affect a listed building's special interest.
Grade II* listed: A building of more than special interest, the middle tier in England's listed building grading system.
Gasholder: A large metal tank historically used to store gas, with a telescoping or fixed structure; here, the listed Gasholder No. 2 at Fulham Gas Works.
Section 16, Planning (Listed Buildings and Conservation Areas) Act 1990: The statutory provision used to assess whether listed building consent should be granted, having special regard to the desirability of preserving the building or its setting.
What was decided, why, and what happens next
Pro reads every officer report for you and explains each decision in plain English: the money, the options, the risks, the timeline, each with the paragraph it came from.
Written by AI from the council's published papers. AI can get things wrong: the council's own wording below is the record.Report a problem
Item8
Resolved
RESOLVED That subject to there being no contrary direction from the Secretary of State, that the Director of Planning and Property be authorised to determine the application and grant listed building consent subject to the conditions listed below (as amended or varied in accordance with 2 below). That the Director of Planning and Property, after consultation with the Assistant Director of Legal Services and the Chair of the Planning and Development Control Committee, be authorised to make any changes to the conditions listed below, which may include the amendment, addition or deletion of conditions, and any such changes shall be within their discretion.
Word for word from the decision Hammersmith & Fulham published for this meeting.Source: democracy.lbhf.gov.uk
Date Valid: Conservation Area: 03.03.2025 Imperial Square & Gasworks Conservation Area - Number 6 Committee Date: 20.01.2026
Applicant: [name removed] 3 Riverlight Quay London SW11 8AY
Description: Works to Gasholder No.2 comprising:
(i) bell and tank wall stabilisation works including concrete pours; (ii) the recording of the existing structure, the dismantling and off-site refurbishment and restoration of part of the existing structure; (iii) the permanent removal of roof sheeting, metal tank walls and infilling of existing void; (iv) the incorporation of replacement components where the original components are degraded beyond repair; and (v) the repainting and erection of the restored and replacement components of the gasholder in a new configuration with required alterations to facilitate the use of the salvaged elements of the gasholder as an integrated feature of the wider landscaped park, including introduction of a water feature and new seating and other associated works.
Drg Nos: See Condition No.2
Application Type: Listed Building Consent
Officer Recommendation:
(1) That the Committee resolve, subject to there being no contrary direction from the Secretary of State, that the Director of Planning and Property be authorised to determine the application and grant listed building consent subject to the conditions listed below (as amended or varied in accordance with 2 below).
(2) That the Committee resolve that the Director of Planning and Property, after consultation with the Assistant Director of Legal Services and the Chair of the Planning and Development Control Committee, be authorised to make any changes to the conditions listed below, which may include the amendment, addition or deletion of conditions, and any such changes shall be within their discretion. Conditions:
Time limit
1) The development hereby permitted shall not commence later than 3 years from the date of this decision.
Reason: Condition required to be imposed by Section 18(1) (a) of the Planning (Listed Buildings and Conservation Areas) Act 1990 (as amended by section 91 of the Planning and Compensation Act 2004).
Drawings
2) The works hereby granted consent shall be carried out and completed in accordance with the following approved documents and drawings:
Follow Planning and Development Control Committee at Hammersmith & Fulham and we tell you when its next papers are published, before the meeting rather than after it.
We use a cookie to keep you signed in and run your free-paper allowance, and an optional one to count visits. You can accept all, or choose. Privacy & cookies
Necessary
Keeps you signed in and runs your free-paper allowance. Always on.
Always on
Analytics
Counts visits and which pages are used. First-party only, no advertising, never shared.